Post Job Free

Resume

Sign in

Electrical Power Plant

Location:
Cuddalore, Tamil Nadu, India
Salary:
1,25,000/-
Posted:
March 08, 2019

Contact this candidate

Resume:

RESUME

P.PRAKASH ***, Grape Street,

E-mail: ac8prk@r.postjobfree.com Periyar Nagar (south),

Vriddhachalam-606001.

Cell: +919*********

JOB RESPONSIBILITIES & EXPERIENCE:-

Present: Siemens Ltd in Neyveli lignite corporation Mines-ii Expn., 14.06.2007 Till date

( Operation & Maintenance)

Previous: Nellai Enterprises in Mettur Thermal power station 08.05.2005 31.03.2007

(Electrical Maintenance Engineer)

Bhuvanesh Electrical in Thermax Engineering 04.08.2004 29.04.2005

(Site Engineer/Madras Cements Ltd/Alathiyur)

Graduate Apprentice Trainning in Electrical Inspectorate 23.07.2003 22.07.2004

Supervisor in Amith Associates Electrical Consultants at Trichy 15.05.2002 22.07.2003

Educational Background

Technical Qualification BE (Electrical) MANOMAINAM SUNDARANAR UNIVERSITY

Current Address Permanent Address

No: 237, Grape Street, No: 237, Grape Street,

Periyar Nagar (South), Periyar Nagar (south),

Vriddhachalam-606 001. Vriddhachalam-606 001.

Cuddalore Dist., Cuddalore Dist.,

Tamil nadu, India Tamil nadu India

Personal Particulars

Age : 41 Years Date of Birth : 17-March-1976

Nationality : Indian Gender : Male

Marital status : Married Passport No : R 0252494

Permanent Residence: India

I hereby declare that all the above mentioned particulars are true to the best of my knowledge.

Yours faithfully

Place : Vriddhachalam

Date : P.PRAKASH

P.PRAKASH

+919********* No. 237, Grape Street,

E-Mail: ac8prk@r.postjobfree.com. Periyar Nagar (South),

Vriddhachalam-606 001,

Cuddalore district.

Tamil Nadu, India

EDUCATIONAL QUALIFICATION

BE., (Electrical) MANOMAINIAM SUNDARANAR UNIVERSITY - 2002

JOB PROFILE

1. NEYVELI LIGNITE CORPORTION:-

Designation : Electrical Engineer (Operation & Maintenance)

Company : M/s Siemens Ltd

Location : NLC, MINES-II Expn., at NEYVELI-2

Duration : JUNE 2007 to Till date.

Job Description

Carry through Erection and Preventative Maintenance on various Electrical and Mechanical equipment such as Transformers, H.T/L.T Panel, Electrical Motors, Lighting, UPS, Batteries, Fire and General alarm systems, Emergency shut-down systems, auxiliary equipments, Power Plant, monitoring systems, automation systems, instrumentation equipments etc.

Trouble shooting, repair and maintenance of electrical systems for different type

Trouble shooting, repair and maintenance of electrical systems in all Gathering Centres, Booster Station, Field Distribution.

Preparing spare parts list as per the requirement.

Maintaining all hand Tools & Power Tools.

Performing other related duties as assigned.

DUTIES AND RESPONSIBILITIES:

Responsible for operation and Maintenance of Electrical systems.

Responsible for operation and Maintenance of various types of Motors.

Responsible for maintenance, Troubleshooting and Calibration of electrical Equipments, tools and machineries.

Responsible for Maintenance of different type of UPS and Batteries.

Responsible for maintenance and servicing of Fire Alarm& fire extinguisher, smoke detector, Heat detectors etc.

Responsible for preventive and Breakdown Maintenance of Cranes.

Responsible for operation, Maintenance and maintenance of Vertical and Horizontal AC and DC Motors.

Troubleshooting and Fault Rectification of Control Panels.

Operating and Maintaining of Air Compressors.

Operating, Maintenance of all types motor Starters.

Responsible for Maintenance of Transformer.

Responsible for maintenance all type of Switchgear.

Installation, repair and maintenance of Circuit Breakers & Motor Starters like Direct On Line, Star - Delta Starters.

Responsible for maintenance of Battery & Battery Charges and UPS System.

Erection of Electrical Panels and Distribution Boards.

Responsible for Cable laying Gladding, Jointing of Cables.

Installation and commissioning of pressure Gauge & Transmitters.

Level Indicators, control valves, Thermocouples,

Good knowledge in PLC and other control Panel wiring.

Cable Joint work in telecommunication (Jelly filled cables 5pair, 10Pair, 20Pair, 50Pair, 100Pair cable).

Maintenance of Fiber Optic Cable Splicing, CCTV Networks, EPABX System etc.

Defective materials replacement and follow up.

ELECTRICAL SAFETY:-

Requirements, familiar with various Safety Equipment and Tools.

LOCK OUT & TAGOUT of Electrical Switch gear during work as per INDIA Standard.

Aware of Electrical Safety Standard.

Proper usage of Protective of Equipments.

2. METTUR THERMAL POWER STATION:-

Designation : Maintenance Engineer (Electrical)

Company : NELLAI ENTERPRISES

Location : Mettur Thermal Power Station

Duration : May 2005 to March 2007.

Job responsibilities:-

Overhauling and Maintenance of Power Plant and Sub Station.

Overhauling of Generating Transformer 15.75KV/6.6KV/433V with VCB

Overhauling work of Turbine T.G. Sets, HP & LP Heaters, Boilers.

Preventive & Breakdown Maintenance of HT Switchgear consist of VCB Breakers, PMCC/MCC, HT/MV Motors with HT Cables (11KV, 6.6KV).

LT Switchgears Consist of ACB Breakers, LT Motors with LT Cables (433v), Lighting Panels.

Hands on experience in Erection, Commissioning, Testing and Maintenance of single phase and three pahase online UPS system feeding to various accessories like DCS, PLC and other computer related systems.

Also having experience in EMS by continuous monitoring the dates like KW,KVA, KVAR, VOLTS, AMPS.

3. MADRAS CEMENTS LTD:-

Designation : Site Engineer (Electrical)

Company : BHUVANESH ELECTRICALS

Location : Madras cements Ltd

Duration : Aug 2004 to April 2005.

Job responsibilities:-

ERECTION, PRECOMMISSIONING AND MAINTENANCE:-

I had experience of Erection, Commissioning and Maintenance of following Electrical equipment/systems.

Planning of requirement of raw materials for process and maintenance needs.

Power Transformer 2500 MVA, 6.6 KV/433v, Station Transformer 1 KVA Erection, Testing & Commissioning.

6.6 KV Bus duct Erection & Commissioning.

Battery Bank & Battery Charger Panel (with UPS) Erection, Testing & Commissioning

6.6 KV Switchyard Equipment Erections, Testing & Commissioning.

HT & LT Switchgear Erection, Testing & Commissioning.

HT, LT & Control Cable Routing, Jointing & Termination.

HT, LT & Control Cable Tray Routing.

Structural Earthing & Grounding of whole plant.

Lighting system & Lightning system of whole plant.

4. GRADUATE APPRENTICE TRAINING:-

Employer : GOVT. OF ELECTRICAL INSPECTORATE

Position : Apprentice Training

Duration : July 2003 to July 2004.

Job responsibilities:-

EHV & HV Substation of TNEB

HV & MV Electrical Distribution arrangements and Maintenance and Testing during Inspection .

Scrutiny of Electrical layout Drawings of high voltage consumers, Cinema Theaters and Lift installation operations.

Electrical Accident Reporting & Investigation in various causes of accidents .

Testing of Voltmeter, Ammeter, Earth Megger, Insulation Megger and Electromagnetic Relay

5.“ MV” ADDITION & ALTERATION WORK:-

Employer : AMITH ASSOCIATES ELECTRICAL CONSULTANTS

Position : SUPERVISOR

Duration : May 2002 to July 2003.

Job responsibilities:-

“MV” Addition & Alteration Installation for the Transformer, Generator, Air Compressor, Exhaust fan, Crane, and Water Treatment Plant.

Lighting Work in Quarters, Colony, Shopping complex, Club & Auditorium, Swimming Pools.

ELECTRICAL LICENSE:-

Tamil Nadu Electrical License Board.

No: C 31055

Valid Date : 23.09.2016 to 22.09.2020

Declaration:

I hereby declare that the information furnished above is true to the best of my knowledge and belief.

Place : Vriddhachalam Yours Sincerely

Date :

(P.PRAKASH)



Contact this candidate