Post Job Free
Sign in

Project Technician

Location:
United States
Posted:
July 05, 2012

Contact this candidate

Resume:

SATYANARAYANA D.V.V

FIN No.: G*******W

Present Address: Block 56#02-48, 58 Penjuru Place, Singapore Postal code - 608562.

Permanent Address : 14-75, Near Sivalayam, Tanuku(T.K), West Godhavari Dist, Andhrapradesh, S.India-534222.

Handphone number:+65-83050352(Singapore)

Email :************@*****.***

Date of Birth : 10th June,1977

Career Objective

To achieve excellence in the tasks entrusted to me and to contribute and upgrade my knowledge for the development of self and the organization concerned.

Academic Profile

1.) Diploma in Electronics Instrumentation, CR Polytechnic, Chilakaluripet,passed out 1995 Scored 63.4%

Career Profile

Total Experience: 16 Years 6 Months

Current Company: Plant Electrical Instrumentation Pte Ltd., Singapore.

(A joint venture between YOKOGAWA and PEC)

Designation : Instrument Foreman.

Period : From 02-June-2010 to till date.

Project 1 : Singapore Parallel Train Project, Olefins Recovery Project

Client : Exxon Mobil Chemical, Jurong Island, Singapore.

Main Contractor : Shaw Energy & Chemicals, USA.

Job nature :

Working under Exxon Mobil Project Management, Completions, Start-up Team for the successful Erection, commissioning and start-up of the Utility area of Olefins Recovery project.

Member of Instrument Erection, Inspection, Loop check, Commissioning & Start-up Team.

Inspection of Instrument erection as per Exxon Mobil Global Practice.

Creating punch lists for instrument field inspection, follow up with main-con and sub-con for clearing those punches.

Interpretation of all Instrument design calculations in the loop folders and verify them.

Reading P&ID, Instrument Data Sheet, ILD, Hook-up and verifying them with the field instrument installation.

Co-ordination of all documentation works related to loop folders.

Familiar with ISA, IEC, NEMA standards.

Verification of instrument installation against Hazardous area classification, Ex-proof ratings, IP ratings.

Co-ordination for the turnover of RIE (Remote Instrument Enclosure) which contains Instrument Power cabinets, Marshaling racks, DCS I/O Module Panels, Communication cabinets.

Inspection, Loop checking and commissioning of Fire & Gas System (Sanko, Italy).

Able to work in Honeywell TDC-3000 DCS system console and also in Triconex PLC systems for safety critical Instruments.

Configuration and commissioning of Rosemount Radar Level transmitters (GWT) – 3300, 5300 Series.

Able to work with Rosemount Radar Master Software.

Configuration and commissioning of FireEye Flame Scanners.

Successfully commissioned Oil Mist Generator system.

Worked with Bently Nevada Vibration Monitoring systems and loop checking the same from field using TK-3 Simulator Kit -3300 XL Series.

Testing and commissioning of Clyde Bergemann Soot blower panel for boilers.

Worked with Fisher DVC-6000 series Smart Control Valves, ROTORK MOV’s.

Well versed with Exxon Mobil Permit to Work, JSA, JHC procedures, LOTO procedures and safety standards.

Co-ordination of SAT for Vendor skids and panels with Main-contractor and Sub-contractor.

project:

Client : Singapore Refining Company,Singapore.

Job nature

Working as Senior Instrument Technician in Construction activities such as Cable laying, Panel Installation, Installation of pressure gauges, switches, temperature gauges, switches, level, thermocouple, RTD, electronic type pressure, flow, level, differential pressure transmitters, control valves, dampers, electrical actuators, analytical instrument, digital indicator and analog indicators, Electrical Control Panel.

Installation of various Instruments like transmitters, pressure gauges, temperature gauges, pressure switches, temperature switches, control valves, RTD, thermocouple as per P&ID and Instrument Location Layout drawing.

Job includes fabrication of cable Tray, Junction box installation, laying all types of cables.

Fire and gas detector installation.

Installation of panels such as 415 Volt LV panel, PLC SCADA, Flow metering, MOV panel, Fire and Gas panel and 24 V DC UPS panel.

Getting the work done as per the scope of work and standard of project procedures.

Clearing PUNCH LIST and turn in system in flow.

Involved in AS BUILT drawing preparation.

Coordination with client.

Handling manpower and reporting to superintendent.

Involved in QC documentation.

Checking of cable termination and ferruling according to the wiring diagram.

Obtaining permit to work for carrying out the installations as per client requirements.

Loop checking of field instruments from field to DCS such as Pressure, Flow, Level, Speed and Temperature Transmitters. Make: Rosemount, Yokogawa.

Calibration of all field instruments according to the customer standards.

Worked with Dresser Leveltrol and Masoneilan Smart Control Valves.

Preparation & Submission of Loop folders and Test package folders to Customer as per SRC standards.

Performing QA & QC Checks such as Continuity checking of cables from Marshaling cabinet to JB and JB to field instrument, Hydro test of instrument impulse lines, and airline flushing and test for pneumatic lines.

Past Company 1: THE ANDHRA SUGARS LTD

Designation : Instrument Technician

Period : From Feb 2005 to May 2010 (5 Years & 3 Months)

Job Nature :

Maintenance job for Instruments like Pressure Transmitters, Temperature

Transmitters, Flow Transmitters.

Did troubleshooting, data logging for above Instruments.

Past Company 2: G.M.R.Industries and technologies

Designation : Instrument Technician

Period : From Nov 1999 to Nov 2004 (5 Years)

Job Nature :

Closely worked with the engineers to complete the job within the schedule.

Performed I/O Checking for the PLC Panels.

Troubleshooting of all types of transmitters.

Loop checking & commissioning of all field instruments.

Past Company 3: The Andhra Sugars Ltd

Designation : Instrument Technician

Period : August 1998 to July 1999 ( 1 Year)

Job Nature :

Maintenance job for Instruments like Pressure Transmitters, Temperature

Transmitters, Flow Transmitters.

Did troubleshooting, data logging for above Instruments.

Past Company 4: The Andhra petro chemicals Ltd

Designation : Instrument Technician

Period : August 1995 to July 1998 ( 3 Years)

Job Nature : Calibration of Pressure gauges, Pressure switches, Flow, Pressure,

Temperature, Vacuum – TX’s checking, general maintenance and

calibration- Checking work, recalibration work

Test Instruments Handled

Emerson HART Communicator 275,375.

Druck Pressure Calibrator.

Fluke Processmeter

Yokogawa CA-100 Multi-function Calibrator.

Dead Weight Tester, High Pressure Pump.

Field Instruments – Yokogawa, Honeywell, Rosemount

Control Valve - Masoneilan Dresser, Fisher, Samson

I/P Converters _ Masoneilan

ON-OFF Valve _ Metso, Rotex

Level _ Dresser Masoneilan, Fisher

Technical skills

Can able to read and understand P&ID, ILD, Loop Diagrams.

Good knowledge in HART and FF communication protocols.

Skills in PLC and DCS systems.

Calibration of field instruments as per the standards.

Fathers Name : Mr. Divi Gopalam

Sex : Male

Age : 34

Language Known : English, Telugu

Passport No : GO180358

Expiry date : 15.11.2016

Available notice period : 1month

Expected salary : 2800 SGD

Declaration

I hereby declare that all the details furnished above are true to the best of my knowledge.

Place: Singapore

Date: 14-FEBRUARY-2012

SATYANARAYANA D.V.V



Contact this candidate