MOHD. ASLAM
Cell:053******* Email:****.*******@*****.***
Over 3 year of experience in Telecommunication
I have worked as DT Engineer SHAH¬¬_I _KIRMAN GROUP Srinagar Kashmir. on Aircell Project in Mumbai
SUMMARY
Over 3 year of experience in Telecommunication domain working in the area of Monitoring Daily Stats, Dealing with Network Inconsistencies, Optimization, Frequency Planning, Neighbor Planning, Drive Test, Drive Test Analysis, RF Survey and RF Site Acceptance Test. Responsibilities include drive test coordination, RF Survey, documentation and client interaction for requirement and information verification to achieve the client goals. Excellent communication skills and ability to work well in team or individual environment.
PROFESSIONAL EXPERIENCE
• Worked as a DT Engineer in SHAH_I_KIRMAN GROUP Srinagar Kashmir
From Feb – 2009 to Aug 2010
SKILLS PROFILE
DRIVE TEST TOOLS: TEMS 8.0.3, TEMS 8.0.4 .GENX probe 1.50, 1.51.
PLANNING TOOL: GOOGLE EARTH, ROMES
POST PROCESSING TOOLS: MapInfo7.0, MCOM4.2, MIPT, RF TOOL, GLOBBAL MAPPER.
PROJECTS
BSNL UTTRAKHAND ERRICSSON PROJECT
RF Engineer, (Feb 2009 to Jul 2009)
Client BSNL Operator BSNL Location : UTTRAKHAND
ROLL AND RESPONSIBILITIES IN NETWORK TEAM
• GSM RF Planning
• Coverage Planning: - Nominal planning (Search ring plan, Antenna height, orientation, tilt, site survey).
• Capacity Planning: - Increase Site configuration, capacity sites planning as per utilization of sectors & sites.
• Frequency Planning: - BCCH Planning & TCH, planning Neighbor list planning
• Lat long verification during new site survey, Nominal Plan for New sites.
• Support survey team movement & SARF submission.
• Global mapper to verify the link clearance in unconditional or conditional regions.
• Performing Drive Tests & analysis of RF Drive Test’s data on TEMS Investigation 8.0.3 (Ericsson), and RF Planning tools like MapInfo etc, to determine network Problems, Poor Coverage areas, Interference, Call drops & Handover Problems.
• Physical Testing, Check the Particular sites physically for Sector and cables swap, orientation, Tilt, Type of Antenna and all checking in BTS.
• After Doing Drive Test for particular sites clockwise and anticlockwise to check Rx level, Rx quality, swap interference and Handovers.
• Analyzing interference, Call Drops, Handover failures, Error in Connection, Channel reselections, Rx Quality, Rx level etc. and generating Rx Level & Quality Plots using MapInfo8.0,8.5 /MCOM.4.2
• Auditing of New Sites and Verifying Hardware, Tilt, Antenna height & Orientation according to the Planning Database.
AIRCEL THROUGH ZTE IN UP WEST
DT Engineer, (Jul 2009 to Sep 2009)
Roll in Network Team:-
• Analysis of Daily reports..
• Performing activities like Frequency hopping, Frequency planning, Neighbor Addition & deletion etc.
• Resolving the problem of cells having high drops by changing frequencies, Checking hardware related problems.
• Radio Frequency planning for non-hopping, Synthesizer Frequency Hopping network Channel groups
• Checking CO-BCCH for solving Handover related problems’
TATA GSM THROUGH ZTE IN ORRISA
DT Engineer, (Oct 2009 to Dec 2009)
Roll in NPI Team:-
• Carrying out coverage, Quality, Cell-Reselection, and Handover test using GENX PROBE in dedicated as well as in IDLE mode to ascertain criteria.
• Converting the Drive test results to the plote formate & to generate the report for taking action. Preparing the Drive Test Routes for Optimization. .
• Post Processing of the collected data using GENX PROBE. Optimizing the Macro Cell allocating the proper Neighbors, Handover Criteria, Cell Select/Reselect criterion etc.
• Collection of Live Network Data using GENX PROBE TOOL and analyzing the performance of their network.
Roll in Drive test
• Physical Testing ,Check the Particular sites physically for Sector and cables swap, orientation, Tilt, Type of Antenna and all Checking in BTS end.
• After Physical Testing of a particular site, check clockwise and anticlockwise Handovers.
• Analyzing interference, Call Drops, Handover failures, Error in Connection, Channel reselections, Rx Quality, Rx level, Sqi etc. and generating Rx Level & Quality Plots using MapInfo.
• Generating Log File Using GENX PROBE Software
• After That Analysis Optimize the Particular sites and Whole Network.
• Drive test & height detection for implementation of Frequency.
• Working as a drive test engineer of optimization drive.
AIRCEL THROUGH ERRICSSON MUMBAI
DT Engineer, (Jan 2010 to Aug 2010)
Roll in NPI Team:-
• Carrying out coverage, Quality, Cell-Reselection, and Handover test using GENX PROBE in dedicated as well as in IDLE mode to ascertain criteria.
• Converting the Drive test results to the plote formate & to generate the report for taking action. Preparing the Drive Test Routes for Optimization. .
• Post Processing of the collected data using GENX PROBE. Optimizing the Macro Cell allocating the proper Neighbors, Handover Criteria, Cell Select/Reselect criterion etc.
• Collection of Live Network Data using GENX PROBE TOOL and analyzing the performance of their network.
Roll in Drive test
• Physical Testing ,Check the Particular sites physically for Sector and cables swap, orientation, Tilt, Type of Antenna and all Checking in BTS end.
• After Physical Testing of a particular site, check clockwise and anticlockwise Handovers.
• Analyzing interference, Call Drops, Handover failures, Error in Connection, Channel reselections, Rx Quality, Rx level, Sqi etc. and generating Rx Level & Quality Plots using MapInfo.
• Generating Log File Using GENX PROBE Software
• After That Analysis Optimize the Particular sites and Whole Network.
• Drive test & height detection for implementation of Frequency.
• Working as a drive test engineer of optimization drive.
EDUCATION
• Bachelor of Engineering (Electronics and Communication) from Afset -faridabad, Maharshi Dayanand University, Rohtak , (Haryana) in the year 2008.
PROJECT UNDER TAKEN DURING PROFESSIONAL CURRICULUM
• One month intensive training on “mobile communication” at Reliance communications Ltd. at Lucknow in 2006.
• One month intensive training on “Networking” at reliance communications Ltd. at Lucknow in 2007.
PEROSNAL DATA
• Name Mohd Aslam
• Father’s Name: Mr Mohd Ikram
• Date of Birth: 5 Sept 1985
• Nationality: Indian
• Marital Status: Single
• Languages Known: English, Arbi , Urdu, Hindi
Is your IQAMA (working permit of Saudi) transferable, Yes/No :- Yes
Profession in Iqama :- Fanni Electroniyat
MOHD ASLAM