Post Job Free
Sign in

Electrician Apply

Location:
United States
Salary:
300 euro /day
Posted:
September 18, 2012

Contact this candidate

Resume:

Name: Gheorghe

Surname: Valentin

Birth date: * September 1962

Nationality: Romanian

Marital status: married

Address: No.3 Poporului Street, Bl.36, Ap.10, Medgidia, Romania.

Phone: +40-729-***-***, +40-766-***-***

Email: ********@*****.***

Specialization: Electrical Technician

Known languages: English - medium

French - medium

Experience: 30 years of professional activity

Professional training:

The industrial High School “Dragomir Hurmuzescu”, Medgidia, electrical profile.

Basic Offshore Safety Induction & Emergency Training Included Huet and EBS (5700) at Training Center of Bornasco (Pavia) – Italy

Date of issue: 26.10. 2008

Date of Expiry: 25.10.2012

SKILLS AND APTITUDES:

I am a fast learning, resourceful and trustful person and I have the ability to work well in a team.

I have the ability to work under pressure and handle difficult situation.

Availability: On request

Period from/until:

• July 2011 – August 2012: I worked at Tozzi Sud S.p.A. for Agip Kazakhstan North Caspian Operating Company – the KASHAGAN FIELD development project (experimental programme), on D Island.

- I held the supervisor position and the team I had in coordination consisted of 20 workers.

- trails cables, cable brackets, JB connections, lighting equipment, mountings fire detection equipment, mountings telecommunication systems, U.P.S connections, medium voltage power cells, support for trails cables, Roxtec – Multi – Diameter Cable, punch list solving for the equipments and systems with erection nonconformities (wrong connections, wrong cables – selection not according to the prescriptions, damage terminals or connectors, damage trails cables, damage earthing connection, megger test (insulations resistance) for the low, medium voltage cables and instrumentation, cable mountings, commissioning - measuring currents and tensions, connections checking, current and voltage measured electro-motors, verification for warning signal systems, smoke detector systems, gas extinguished system, valves - equipment used: Unilap Iso 5 KV norma insulation tester, Megohmmeter Fluke 1520, Clamp Meter 337 Fluke, Ground Fault Detector, Multimeter Fluke, has been installed and checked EEx Cables Glands.

- install industrial instruments and equipment such as control panels, sensors, transmitters and controllers, montage in positions of instruments assembling metallic beams for supports, work shop activities, including large steel structures manufacturing.

August 2010 – June 2011: I worked at PETROSERV SA for PETROM OMV-GROUP offshore repairs and maintenance (Black Sea). I held the technician electrician position.

- trails cables (300x100, 500x100, 600x100), cable brackets, cable mountings, JB connections (fire resistent cables 3x2,5), lighting equipment (lamps EEx with 125 W), fire detection equipment, engines repair and overhaul, electrical panels equipped with ventilation systems, with kitchen appliances, with Moeller and Schneider devices.

January 2010 – July 2010: I worked at Fincantieri - Site naval Italy S.p.A. - Genoa for Automation System Service (APSS). I held the technician electrician position

- trails cables, valve system, cable pulling (2x0,75), limit switch box, Roxtec - Multi-Diameter Cable, megger test, terminal ends, 3M technology, connections electric system, mountings fire detection and gas system,mountings door limiters.

November 2008 – August 2009: I worked in Italy at Global Energy – Aker Solutions, for EXON MOBILE, on a L.N.G platform. I held the position of foreman electrician.

- trails cables (dimension: 50x35, 100x35, 300x35, 300x100, 500x100, 600x100), cable brackets, JB connections (4x1,5, 3x2,5, 3x6, 5x16, 5x25, fire resistent cables) lighting equipment (lamps EEx with 125 W, 250 W, 400 W), mountings fire detection equipment, mountings telecommunication systems, U.P.S connections, medium voltage power cells, support for trails cables, Roxtec – Multi – Diameter Cable, punch list solving for the equipments and systems with erection nonconformities (wrong connections, wrong cables - selection not according to the prescriptions, damage terminals or connectors, damage trails cables, damage earthing connection, inter cell loops not according to the connection diagram), megger test (insulations resistance) for the low, medium voltage cables and instrumentation (4x1,5, 3x2,5, 5x25, 5x16), cable mountings (19x1, 21x1, 30x1,5, 5x16, 5x25, 4x1,5, 3x2,5, 3x6), commissioning - measuring currents and tensions, connections checking, current and voltage measured electro-motors, verification for warning signal systems, smoke detector systems, gas extinguished system, valves - equipment used: Unilap Iso 5 KV norma insulation tester, Megohmmeter Fluke 1520, Clamp Meter 337 Fluke, Ground Fault Detector, Multimeter Fluke, has been installed and checked EEx Cables Glands (M16x1,5, M20x1,5, M25x1,5, M32x1,5, M40x1,5).

July 2008 – September 2008: I worked in Spain for Global Energy – Aker Solutions on a L.N.G platform. I held the technician electrician position.

- I have been installed and checked EEx Cables Glands (M16x1,5, M20x1,5, M25x1,5, M32x1,5, M40x1,5), trails cables (dimensions: 50x35, 100x35, 300x35, 300x100, 500x100, 600x100), cable brackets, JB connections (4x1,5, 3x2,5, 3x6, 5x16, 5x25, fire resistent cables), lighting equipment (lamps EEx with 125W, 250W, 400W), mountings fire detection equipment, mountings telecommunication systems, U.P.S connections, medium voltage power cells, Roxtec – Multi – Diameter Cable, commissioning: punch list solving for the equipments and systems with erection nonconformities (wrong connections, wrong cables – selection not according to the prescriptions, damage terminals or connectors, damage trails cables, damage earthing connection, inter cell loops not according to the connection diagram, to repair the cable outer insulation was used Raychem Technology and 3M Technology), megger test (insulations resistance) for the low and medium voltage cables, cable mountings (19x1, 21x1, 30x1,5, 5x16, 5x25, 4x1,5, 3x2,5, 3x6).

• 2006 – 2008: I worked for Chevrone Oil, Kazakhstan, Tenghiz (petroleum refinery).

- I held the team leader position.

- trails cables (dimensions: 50x35, 100x35, 300x35, 300x100, 500x100, 600x100), cable brackets, protection pipes, JB connections (4x1,5, 3x2,5, 3x6, 5x16, 5x25, fire resistent cables), lighting equipment (lamps EEx with 125W, 250W, 400W), fire detection equipment, telecommunication systems, medium voltage power cells, support for trails cables, punch list solving for the equipments and systems with erection nonconformities (wrong connections, wrong cables – selection not according to the prescriptions, damage terminals or connectors, damage trails cables, damage earthing connection, inter cell loops not according to the connection diagram), megger test (insulations resistance) for the low voltage cables, cable mountings, commissioning - measuring currents and tensions, connections checking, current and voltage measured electro-motors, verification for warning signal systems, smoke detector systems, gas extinguished system, valves - equipment used: Unilap Iso 5 KV norma insulation tester, Megohmmeter Fluke 1520, Clamp Meter 337 Fluke, Ground Fault Detector, Multimeter Fluke.

• 2004 – 2006: I worked at S.C Elcomex I.E.A, for the Italian-Canadian group A.E.C.L. ANSALDO - Nuclear Power Headquarters Cernavoda. I held the team leader position

- trails cables (dimensions: 50x35, 100x35, 300x35, 300x100, 500x100, 600x100), cable brackets, protection pipes, JB connections (4x1,5, 3x2,5, 3x6, 5x16, 5x25, fire resistent cables), lighting equipment (lamps EEx with 30 W, 125 W, 250 W, 400 W), fire detection equipment, telecommunication systems, U.P.S connections, medium voltage power cells, support for trails cables, megger test for the low, medium voltage cables and instrumentation cable (5x16, 5x25, 3x120, 3x150, 3x185, 1x2x0,75, 19x1, 30x1,5) commissioning - measuring currents and tensions, connections checking, current and voltage measured electro-motors, verification for warning signal systems, smoke detector systems, gas extinguished system, valves - equipment used: Unilap Iso 5 KV norma insulation tester, Megohmmeter Fluke 1520, Clamp Meter 337 Fluke, Ground Fault Detector, Multimeter Fluke.

2000 – 2004: I worked for Sursal S.A. Salygni (manufacture of mechanical assembling equipment). I held the position of foreman electrician.

- electrical equipment, medium and low voltage, lighting equipment (lamps EEx with 125 W), panels and electrical motors connections, telecommunication systems, cable brackets, trails cables (dimensions: 300x100), commissioning, megger test (insulations resistance) for: low and medium voltage cables, low and medium voltage motors (0,75 132Kw), switchboards, power transformer (20/04Kv, 6/04Kv) voltage and current transformers, cable mountings (5x16, 5x25).

• 1981 – 2000: I worked for Lafarge Romcim Concern, Medgidia. I held the team leader position

- electrical equipment (switchboards), medium and low voltage, electrical panels, electrical connections, trails cables (dimensions: 300x100, 500x100, 600x100), cable brackets, cable mountings (3x120, 3x150, 3x185, 5x16, 5x25) fire detection equipment, gas detection equipment, smoke detection equipment, electrical transformers 110/6 kV, 20/04 kV, 6/0.4 kV, commissioning, megger test (insulations resistance) for: low and medium voltage cables, low and medium voltage motors 0,75 1600 Kw (connection cable, measuring currents), switchboards, power transformers (110/6Kv, 6/0,4Kv, 20/0,4Kv), changing current transformers.



Contact this candidate