Dawei Zhu (***) –***-**** c1hnx6@r.postjobfree.com
***-****, ********** ****, ********, H4B 1N6
PROFILE
Completed Bachelor and Master degree in electrical engineering with emphasis on High Voltage, Transformer Testing, System Reliability and Maintenance Management and Enterprise Asset Management Software
Expertise in Transformer testing & design, High Voltage equipment maintenance, installation and testing
Familiar with High Voltage test requirements and industry standards & methods including ISO, ANSI, CSA, IEC, Canadian Electrical Code, Health & Safety practices
Team player, highly self-motivated, welcome challenge and competition
EDUCATION
Master of Science in Electrical Engineering 2009
École Polytechnique de Montréal (Université de Montréal)
Thesis: Thermal Behaviour of Dry-Type Transformer
Bachelor of Science in Electrical Engineering 2005
North China Electric Power University (NCEPU)
Thesis: Research on the Measurement Method of Leakage Current of Composite Insulator in Laboratory
Bachelor of Arts in English language and literature 2005
North China Electric Power University (NCEPU)
COMPUTER SKILLS
MATLAB, Simulink, Labview, OPAL-RT, Protel. HFSS, ADS, EMTP, EXAKT Software Enterprise Asset Management (BE, EE and ASE version), ERP, PM Software AutoCAD, Microsoft Office Suit (Word, Excel, PowerPoint, Outlook, Viso etc.),
CAREER-RELATED EXPERIENCE
Consultant and Project Engineer, Softransfer Consulting Inc Montréal, Québec 2009-present
Provided maintenance program support for manufacturing facility to achieve plant goals for safety, quality, reliability, productivity and cost
Developed and executed plans to reduce equipment failures, reduce repair times and improve equipment performance
Provided day-to-day prioritization and decision and operational support for maintenance operations
Designed various testing circuits and protection systems for real-time electrical machinery diagnostics
Trouble shooting final product for defects
Experienced with utility metering, and circuit monitoring applications
Developed and taught training courses to Engineer group
Deal directly with customers and sponsors to resolve issues
Provided technical support to branch sales staff, assisted in the development of new procedures to ensure projects well-prepared & documented for the field
Responsible project: Condition based maintenance of wind turbine systems under varying operating conditions
Research Assistant, Laboratoire en énergie électrique (LEE), Montréal, Québec 2009
Project: Thermal behaviour of the dry-type transformer
Simulated and built transformer model with Matlab Simulink
Commissioned and utilized the test bench including the power supply and the measurement apparatus for tests on dry type distribution transformers
Supervised and performed industry standard tests including Open Circuit, Short Circuit and Back to Back tests on distribution transformers, including Induced, Core Loss and Load loss measurements and Temperature rise measurement.
Developed test circuitry and protection system
Measured and analyzed the temperature rise on dry type distribution transformers
Research Assistant, Poly-Grames Laboratory, Montreal, Quebec 2007
Project: Wireless system for elder falling detection and positioning
Simulated on the Circular Polarization RFID antenna with HFSS and ADS at 2.45Ghz
Set up the fall-down system; cooperated with the other two engineers
Research Assistant, Laboratory of Industrial Chair on Atmospheric Icing of Power Network Equipment (CIGELE), Choutimi, Quebec 2006
Project: Experimental Study and Mathematical Modeling of Flashover of EHV Insulators Covered with Ice
Designed and installed the test bench for porcelain post insulators which are typically used in the Hydro-Quebec 735 kV substations
Investigated two experimental methods -an icing regime and a melting regime- to evaluate the minimum flashover voltage of ice-covered insulators
Updated the mathematic module for EHV Insulator
Research Assistant, High Voltage Lab (NCEPU), Baoding, Hebei 2005
Project: Research on the Measurement Method of Leakage Current of Composite Insulator in Laboratory
Installed the climate room and measurement circuits
Measured the leakage current of 10kV composite Insulator;
Evaluated and analyzed data, prepared measurement reports
Participated in various high voltage testing in power transformers, insulators and cables
Electrical Engineer Assistant, China Huadian Engineering CO., LTD, Beijing, China 2005
Conducted with the test equipments related to design, responded and resolved issues
Analyzed manufacturers’ hardware and drawings
Prepared sketches and reports associated with project-related designs or generic standard designs
Verified the wiring of the protection circuits, control and instruments
Tested and maintained the DC systems and UPS systems
Prepared test measurement reports and other technical documents
LANGUAGE
English, French and Chinese
AWARDS AND HONOURS
Research Assistantships at École Polytechnique de Montreal 2007-2009
Research Assistantship at UQAC 2006
Best BS thesis, North China Electric Power University 2005
Excellent Students’ scholarship 2001-2005
PUBLICATIONS
Dawei Zhu, research on “Comportement Thermique” will be accepted by Électrotechinque, Réal-Poul Bouchard and Guy Olivier (Editor): Presses internationals Polytechnique Chapter 3.21
Zhang Zhongyuan,Li Chunyan, Zhu Dawei, Lu Fangcheng,Research on the Measurement Method of Leakage Current of Composite Insulator in Laboratory, the Seventh International Conference on Electronic Measurement & Instruments,2005,Aug.15-17, Beijing, China, Vol.1, pp: 214-217
REFERENCES AVAILABLE UPON REQUEST