Post Job Free
Sign in

Electrical Engineer

Location:
New delhi, DL, 110062, India
Salary:
$100/day
Posted:
December 12, 2010

Contact this candidate

Resume:

Curriculum Vitae

Manoj Kumar Sah

Testing & Commissioning Engineer

+919*********

********.****@*****.***

Currently working As a Testing & Commissioning Engineer with

M Tekpro Engineering Pvt Ltd, New-Delhi.

Project Details:

Feb-2010-till the date: M/S CAIRN ENERGY, Rajasthan

Mangala Processing Terminal (Oil Extraction plant)

Responsibility: Testing & Condition Monitoring of Electrical Equipments

FRA and Tan delta test of Transformers, Relay Coordination and Relay testing, Very low frequency (VLF) tests on cables.

Online condition monitoring of electrical equipments: Motor Current Signature Analysis, Thermography, Online cable diagnostic, Vibration Analysis through Electrical Signature.

Dec-2009-Feb-2010: M/S Kaiga Generating station(KGS), NPCIL

KGS Unit 3&4, Nuclear Power Corporation India limited.

Responsibility: Testing & Commissioning.

Verification and modification of single line diagram, control schemes and cables schedules. Relay coordination and testing of Power Transformer, circuit Breaker, and Siemens Hi-burden electromagnetic relays like CDG,CAD, VAG, Power relays, frequency relays, etc.

Sep-2009-4th Dec 2009: M/S Schneider Electric, Abu Dhabi

Abu Dhabi Polymers Company Limited (Borouge-2 Project)

Ruwais, Abu Dhabi, UAE

Responsibility: Testing & Commissioning

Preparation of relay coordination study, load studies, short circuit calculation of 11KV and 415V Incoming/Outgoing feeders and testing of Sepam 20, 40, 80 series and latest Outgoing Motor control TeSys T Relays and commissioning of all relays according to the setting values on No-load/load Upgradation of relays firmware and programming of re-acceleration type of motors.

Mar-2009-Aug-2009: M/S L&T Limited-Panipat.

MSQ UPGRADATION PROJECT.PANIPAT REFINERY

Indian Oil Corporation limited (IOCL).

Responsibility: Testing & Commissioning.

Testing and Commissioning of New 33/6.6/.433KV Sub-Station, Scheme Check, modification and verification as per in built of 33 & 6.6KV Siemens panel board and 415V L&T panel board. Testing of 31.5MVA Power Transformer, Distribution transformer, circuit Breaker, 6.6KV Bus Bar, Cables, Capacitor bank, Motors, and Siemens Siprotec Relays (7SJ series), SFU & MCCB LT feeders, and circuit breaker of L&T.

Dec.2008-Mar-2009: M/S L&T Limited-Panipat.

PANIPAT NAFTA CRACKER PROJECT (PNCP).PANIPAT REFINERY

Indian Oil Corporation limited (IOCL).

Responsibility: Testing & Commissioning.

Testing and Commissioning of New 33/6.6/.433KV Sub-Station, Scheme Check, modification and verification as per in built of 33 & 6.6KV Siemens panel board and 415V L&T panel board. Testing of 31.5MVA Power Transformer, Distribution transformer, circuit Breaker, 6.6KV Bus Bar, Cables, Motors, and Siemens Siprotec Relays (7SJ series), ABB Relays (R series), SFU & MCCB LT feeders, and circuit breaker of L&T.

May.2008-Dec.2008: M/S ABB Limited –New-Delhi.

DELHI METRO CORPORATION LIMITED (DMRC Project)

Yammuna Bank & Yammuna Bank Depot Station.

Responsibility: Testing Engineer.

Testing of Relay and Relay coordination of 33KV/415V, Incoming/Outgoing feeders and testing of ABB REM series and SPAJ 140C and testing of Transformers, Circuit Breaker and relays according to the setting values on No-load/load.

Jul.2007 -Mar.2008: Areva T&D/ L&T Limited.

Commissioning of 2 x 5 MW Generator Static & Protection relays.

TATA Steels Ltd, Tatanagar, Jharkhand

Responsibility: Testing Engineer

Relay testing and coordination study, setting values for the Generator protection relays, Simulation and commissioning the generator on No-load.

SERVICE-: System Design, Testing and Commissioning Engineer with Managerial Grade, R&D Application & testing support.

A First Class Electrical and Electronics Engineering Graduate with 3.5 years of experience as a Project Engineer-Commissioning.

Design, Calculation and Preparation of Relays Coordination, Short Circuit Fault current, and methods of testing numerical Protections and Enabling.

Commissioning of protection systems with station automation system and electromagnetic relays.

Configuration of Numerical Protection terminals as per system requirement.

Customer complaint resolution and fault analysis, Training to customers on various Protection.

Special/Diagnostic test like Flux Frequency Test(FFT/FRA), Thermography(TI), Motor Current Signature Analysis(MCSA), RLA of Electrical Equipments, AC Very Low Frequency test, Online/offline Partial Discharge test, Tan Delta AC & DC HI- POT, Dielectric Losses.

Commissioning of ABB (REX Series REM Series), SIEMENS Siprotec (7SJ series, 7UT series, and 7SD series), SCHNEIDER (Sepam series & TeSys), Areva (P-521, P-221), Mi-com, and Alstom Relays.

Commissioning of CAG, CDG, VAG, SPAM, VDG, VAG, VAA, CTUM, CCUM and more electromagnetic types relays.

Various type of protection relays like Generator protection, Cable Differential, Line protection, Transformer Protection, Transformer Differential protection with pilot wire, Motor Protection, Bus Bar protection, stability & sensitivity, and Synchronization, Feeder Differential, Motor & Generator Differential.

Feeder Protection & Control terminals: REF 543-5, REX 521, REJ 523, REJ 525, Comb flex relays & REC 670.

Cable/line Differential relay: Areva (P-521, P-221), Mi-com, and Alstom.

Configuration Tools: Digsi, Omicron, ISA, power suite, SFT2841, Micom Studio, PMC600, Simulator software and more.

PRE-COMMISSIONING AND COMMISSIONING OF:

Pre-Commissioning and Commissioning of new 220KV overhead and underground distribution network & substations, and commissioning of 33KV Gas Insulated System (GIS), 66KV AIS along with all protection System.

Pre-Commissioning of Electrical Equipments like Generators, Under ground Cables, Power Transformers, Reactors, Motors (HT & LT), Alternator, Distribution transformers, Current Transformer(400KV), potential transformers, Electrical switchgear (HT & LT).

Commissioning of numerical protection relays and electromagnetic relays.

Calibration, testing and commissioning of electrical protection relays such as o/c, instantaneous o/c relays, time delayed o/c relays, definite time relays, directional o/c relays, differential relays and reverse power relays.

Various types of system electrical equipments like isolators, capacitor banks, reactors, surge arrestor’s, breakers, Battery Charger, UPS, Battery bank.

Calibration and error adjustment of energy meters, power factor meters, ammeters, voltmeters, kilowatt meters, including digital meters.

Excellent grasping capability and understanding the concepts clearly

Ability to adjust to the situation.

Ability to work under pressure and deadline situations.

Sense of Responsibility and a smart hard worker.

A Self motivated team player, with excellent confidence & commitment

Interested to learn more about new technologies.

Like to watch and play football.

Interested in cooking and eating.

Bachelor of Engineering (Electrical & Electronics) in June 2007 from Bapuji Institute of Engineering and Technology, Davangere Bangalore, INDIA.

Higher Secondary School in July 2002 from Siddharth Residential School Vijayawada, INDIA

Secondary School in June 2000 from Gautam English Secondary School, Birgunj, NEPAL

Name : Manoj Kumar Sah

Birth : 26.01.1985

Marital Status : Single

Passport Number : 4062687

Issue Date : 09.07.2008

Expiry Date : 08.07.2018



Contact this candidate