Paul Burke
Facilties mechanic for over ** years Hvac units troubleshooting circuits
Ronkonkoma, NY
Professional Summary
• . Maintenance Mechanic at Eastern Wholesale fence Calverton NY. start date 11/14/21 end date 02/11/23 laid off do to lack of work.Manufacture of PVC fencing, six extrusion lines Maintenance maintains. .All parts of systems PVC powder delivery system pipelines are maintenance maintained. .In order to clean and or break up rock hard powder. Using hammer to hit pipe inder to break up rock hard powder All notching. Machines maintained by maintenance VFD murcury switches contactors powder delivery system .Machines. .Are maintained by maintenance. Chiller system maintenance. 11/14/21 to 02/11/23
Authorized to work in the US for any employer
Willing to relocate to: Ronkonkoma, NY - Smithtown, NY - Deer Park, NY Work Experience
machine mechanic
ISP Millwork Ronkonkoma, NY
March 2026 to April 2026
ISP Millwork bought machines at auction, but they did not work. The company makes custom wood cabinets for business or for your home. The first machine they had me work on was the main bus of power wiring to the contactors in the circuit. The power wiring was wired incorrectly. I showed my boss, and it took me a few hours to fix it. Most of the work he had me do was facilities work. After working there for 7 weeks, they sat me down to tell me I'm not a good fit for them. facilities maintenance technician
Cytiva Hauppauge, NY
June 2025 to March 2026
Facilities Maintenance Technician. I was working at Cytiva through a job agency I had no medical insurance. HVAC units: replace filters, check belts, if the motor bearing needs to be replaced, replace it, shut down the unit, remove the motor, do the repair, then reinstall. Replaced led light when they don't work, plumbing upgraded fauced system from sensors to T&S foot pedal using Milwaukee pro press no need to have boss fill out fire report. I tested the ater on steam boiler with the Myron L test kit Monday to Friday. Facilities Mechanic
Nestle-Bohemia NY
June 2025 to March 2026
Cytiva Hauppauge, NY, facilities mechanic
. Performed basic maintenance on HVAC units, including filter replacement, checking belts, and replacing them if needed
. Helped maintain the steam boiler by checking the water with the Myron tester, Monday through Friday.
. Replaced no-good LED light panels; installed a new exhaust fan on the roof. The area the exhaust fan is for is a production cleanroom setting, so you have to install a plastic curtain from the ceiling to the floor. The fan did not work because there were loose connections in the junction box
. A production clean room, when you enter, there is a sink where you wash your hands. When you see your hands, the water comes out. The manager had me install the T& S floor pedal using the Milwaukee Pro Press. I was working through job agency, so I had no medical insurance that's why I left. Facilities Mechanic
Nestle Bohemia, NY
February 2023 to November 2024
* Maintained HVAC systems across three buildings, checking and replacing filters and belts as needed
* Performed lockout/tagout (LOTO) procedures to ensure safety during maintenance
* Conducted preventive maintenance on exhaust fans and lighting systems
* Upgraded lighting to LED panels and handled plumbing and painting tasks
* Managed maintenance for approximately 126 HVAC units across multiple buildings Maintenance Mechanic
Aladdin packaging Hauppauge, NY
November 2021 to November 2021
• Basic building adding Led lights and removing old lighting and adding outlets.
•
• Ten color printing presses basic PMs grease bearing on rollers, repair pumps. Maintenance Mechanic
Aladdin Packaging Hauppauge, NY
November 2021 to November 2021
* Installed and upgraded LED lighting and electrical outlets throughout the facility
* Performed preventive maintenance on ten-color printing presses, including greasing bearings and repairing pumps Facilities Mechanic
Chembio Diagnostic Systems, Inc. Medford, NY
March 2020 to June 2021
In my first month, they moved four machines and added four more machines. One machine threephase 480 volt, 3 machines three phase 208 volt they were run BX from panel box in celling to 1900 box dropped down SO cable to twist-lock connector. The 480 volt machine EMT from electrical panel to machine. Facilities Mechanic
Chembio Diagnostic Systems, Inc. Medford, NY
March 2020 to June 2021
* Relocated and installed multiple machines, including three-phase 480V and 208V equipment
* Ran BX and EMT conduit from panel boxes to machines, ensuring safe electrical connections
* Installed SO cable and twist-lock connectors for machine power supply Senor Facilities Mechanic/Technician
A&Z Pharmaceutical Hauppauge, NY
January 2015 to February 2020
First building 180 Oser Ave they shipped all product to China Chinese based company when cov-19 happen all manufactuing stopped
• Monitor all Hvac on BMS systems record data Trane ES on shop computer 4 Trane 3 phase 480 volt, all basic maintenance filter changes as needed grease bearings as needed change belts as needed. Compressors basic maintenance filter change clean coil
• 2 Dust collectors systems basic maintenance
• Ro water system record data and add salt as needed
• 2 Hvac Trane 18.50-ton airflow output, no belts direct drive Power wash coils once a year.
• Second building 350 wireless
• 3 Dust collectors systems basic maintenance
• Second building 350 Wireless Blvd
• 3 compressors record data and basic maintenance
• 2 Cleaver brooks boilers Allen-Bradley touchscreen controls record data
• AAon hvac 50 ton airflow output, no belts direct drive replace filters as needed.
• 13 office Hvac units change filters and belts as needed
• Chiller system for compressors Fluid bed system automated. Senior Facilities Mechanic/Technician
A&Z Pharmaceutical Hauppauge, NY
January 2015 to February 2020
* Monitored and maintained HVAC systems using BMS, including Trane 3-phase 480V units
* Performed preventive maintenance on compressors, dust collectors, and RO water systems
* Maintained Cleaver Brooks boilers with Allen-Bradley touchscreen controls
* Managed chiller systems and automated fluid bed systems
* Ensured regulatory compliance and recorded operational data for all major systems Maintenance Mechanic/Technician
Luitpold Pharmaceuticals Shirley, NY
September 2010 to April 2011
•Inspect machines to locate and troubleshoot problems with equipment, then dismantle machines to replace defective parts.
•Preventive maintenance on high speed production line equipment and quality control inspections on equipment
•Troubleshoot and improvise mechanical/ electrical solutions when problems occur
•Expert knowledge of production line equipment
•Excess knowledge of Pneumatics and Hydraulics
•Performed change-over, set up and adjustments
•Work with PLC's
Maintenance Mechanic/Technician
Luitpold Pharmaceuticals Shirley, NY
September 2010 to April 2011
* Inspected and troubleshot high-speed production line equipment, replacing defective parts
* Performed preventive maintenance and quality control inspections
* Developed mechanical and electrical solutions for equipment issues
* Operated and maintained pneumatic and hydraulic systems
* Conducted equipment change-overs, setups, and adjustments
* Worked with PLCs to support production operations Lead Maintenance Technician
Time Cap Labs INC Farmingdale, NY
February 2009 to September 2010
•Completely remodeled the entire packaging lines by making them self sufficient.
•Preventive maintenance on high speed production line equipment and quality control inspections on equipment
•Added electrical eyes that controlled relays and contactors, which shut off sections automatically.
•All the production tablet press machines had major electrical issues, which I revamped to ensure proper safety and operation of the equipment.
•Preventative maintenance on HVAC units including changing air filters, adjusting belts, also troubleshooting control circuits.
•I installed an entirely new and separate service for the Shipping and Receiving department.
•As an electrician, I am knowledgeable on how to bend conduit pipe EMT 1/2 inch up to 3/4 and rigid. Lead Maintenance Technician
Time Cap Labs INC Farmingdale, NY
February 2009 to September 2010
* Remodeled packaging lines to improve efficiency and self-sufficiency
* Performed preventive maintenance on production and HVAC equipment
* Installed electrical eyes, relays, and contactors for automated shutdowns
* Revamped tablet press machines to enhance safety and operation
* Installed new electrical service for shipping and receiving department
* Bent and installed EMT and rigid conduit for facility wiring Mechanic Technician/ Electrician
Fab-Con Machinery Port Washington, NY
December 2006 to January 2008
•All components mounted parts done by drilling and tapping holes into back panels.
•Mechanical assembly of textile machines.
•Wiring on ALLEN-Bradley PLC, slc 500 and drives and Baldor motors.
•Excess knowledge of pneumatics and hydraulics
•Testing completed in one day by troubleshooting electronic circuits and programming.
•I also did all of building electrical maintenance. Mechanic Technician/Electrician
Fab-Con Machinery Port Washington, NY
December 2006 to January 2008
* Assembled and wired textile machines, including drilling and tapping for component mounting
* Wired ALLEN-Bradley PLCs, SLC 500, drives, and Baldor motors
* Maintained building electrical systems and performed troubleshooting
* Operated and maintained pneumatic and hydraulic systems
* Completed electronic circuit testing and programming Controls Technician/ Electrician
Dejana Industries INC Port Washington, NY
February 2004 to December 2006
•Repaired all electrical maintenance problems on service trucks and vehicles.
•Built control panels with PLC's and installed them onto new and old snow melting machines.
•Testing, by troubleshooting electronic circuits of PLC and component parts. I assisted in purchasing electrical supplies.
Controls Technician/Electrician
Dejana Industries INC Port Washington, NY
February 2004 to December 2006
* Repaired electrical systems on service trucks and vehicles
* Built and installed PLC control panels for snow melting machines
* Troubleshot electronic circuits and component parts
* Assisted with purchasing electrical supplies for maintenance needs Control Systems Technician
Link Control Systems Ronkonkoma, NY
May 1992 to February 2003
•Manufactured industrial control panels and systems Interpreted mechanical blue prints and schematics.
•Mounted all electronic components by drilling and tapping into back panels.
•Wired many types of PLC's, drives and electrical starters.
•Supervised production line for five years.
•Built 30 Bridge control systems throughout the United States. Control Systems Technician
Link Control Systems Ronkonkoma, NY
May 1992 to February 2003
* Manufactured industrial control panels and systems for various applications
* Interpreted mechanical blueprints and schematics for system assembly
* Mounted and wired electronic components, PLCs, drives, and starters
* Supervised production line operations for five years
* Built 30 bridge control systems across the United States Education
Electrical PC Boards, House Wiring, Commercial Wiring (High school or equivalent) Boces Bellport
June 1978 to June 1980
Electronics, Troubleshooting to Component Level, House Wiring, Commercial Wiring
(Trade school)
Boces Bellport
1979 to 1980
Upper secondary education
High school diploma or GED
Trade school
electrtronics lurning how to troubleshoot to component level also house wiring and commercial wiring (Trade schoolBoces Bellport 1979 to 1980) Skills
Mechanical systems repair Mechanic experience Leadership Safe work practices Property maintenance Regulatory compliance management Programmable logic controllers Writing skills Blueprint reading Laboratory experience Mechanical knowledge Equipment troubleshooting Manufacturing maintenance Mechanical troubleshooting Electrical systems Maintenance Construction painting AS9100 Electrical troubleshooting Organizational skills Precision measurement in machining Lift truck Calipers Facilities maintenance Teamwork Major aircraft overhauls Plumbing system maintenance and repair Computer skills Handyman experience Conveyor systems mechanical work Productivity software Decision making Renovation Microsoft Office Electrical experience Sheet metal Hydraulics Microsoft Outlook Human resources Air conditioning Regulatory compliance GMP Forklift Industrial equipment Schematics Voltmeter Boiler Soldering HVAC system installation HVAC Data entry Electrical work PLC maintenance Computer operation Equipment repair Event breakdown Electrical maintenance Machining equipment Team management Distributed control systems Manufacturing Math Vendor coordination Driving IPC 610 Electrical Management Computer networking Event cleanup Manufacturing company experience Workplace health and safety regulatory compliance NEC Vendor relationship management Cleaning Microsoft Project Multimeters Industrial equipment troubleshooting Pneumatic systems Maintenance management Construction Windows Electrical diagnostics Maintenance work Plumbing Occupational safety regulation compliance Carpentry Electrical building codes Industrial maintenance Problem-solving HVAC system repair Microsoft Word CMMS Electrical switchgear Time management Attention to detail Mechanical assembly Industrial mechanic experience Equipment testing Hand tools Service technician experience Inspection tools Assembly Variable refrigerant flow (VRF) HVAC systems Mechanical drawings Vendor compliance audits Ductwork English Pharmaceutical manufacturing facility experience Fabrication Basic math Project management Power tools Low voltage Mechanic Soldering irons Electrical equipment repair Communication skills Quality inspection Ohmmeter Electrical repair Safety regulations Drywall CGMP Electrical motors Engineering troubleshooting Equipment installation Facility inspection
Languages
English
Certifications and Licenses
Driver's License
Additional Information
Authorized to work in the US for any employer
Cytiva Hauppauge, June 2025 to March 2026
Facilities Maintenance Technician
Performed basic maintenance on HVAC units, including filter replacements and belt checks. Inspected and maintained the boiler daily
Ensuring proper operation. Handled all electrical and plumbing Issues Throughout the facility. Tested steam boiler water with Myron L test kit Monday through Friday. Upgraded faucet system from sensor-activated to T&S floor pedal using Milwaukee Pro Press. Ensured compliance with the workplace health and safety regulations Supported production by minimizing equipment downtime through timely repairs.