LATHEESH CHANDRAN
LDAR Technician & NDT Inspection Specialist (Ultrasonic Testing & Fugitive Emission Monitoring)
Location: Kuwait City, Kuwait Phone: +965-******** / +91-952******* Email: *************@*****.*** PROFESSIONAL SUMMARY
15+ years of extensive experience in the Oil & Gas, Refinery, and Petrochemical sectors across Kuwait and Qatar specializing in NDT Inspection, Ultrasonic Testing (UT), and Leak Detection & Repair (LDAR) support activities.
Proven expertise in reading and reviewing P&ID diagrams, isometric drawings, and equipment databases to identify light hydrocarbon and gas service lines and verify fugitive emission components. Well-versed in USEPA Method 21 (EPA-453/R-95-017) guidelines, carrying out LDAR fugitive emission surveys, site-based leak rate calculations, and vapor analyzer measurements. Experienced in utilizing advanced inspection equipment including IR / Thermal Imaging Cameras (FLIR T640), Toxic Vapor Analyzers (TVA), and Ultrasonic Leak Detectors (VPAC II) for monitoring flare relief valves and gas service lines.
Strong background in field team coordination, scheduling assistant technicians, maintaining daily monitoring records, generating 15-day/30-day cycle reports, and issuing online/shutdown repair work orders under strict QHSSE standards.
CORE COMPETENCIES & TECHNICAL SKILLS
Domain Technical Capabilities & Standards
LDAR & Emission Monitoring USEPA Method 21 (EPA-453/R-95-017) Compliance, Fugitive Emission Surveys, Site-Based Leak Rate
Calculations, Leak Flagging & Route Setup,
Component Classification (Repairable Online vs.
Requires Shutdown).
Inspection & Testing Equipment VPAC II (Ultrasonic Flare Relief Valve Monitoring), Advanced IR & Thermal Imaging Cameras (FLIR
T640 / OGI), Toxic Vapor Analyzers (TVA), Ultrasonic Thickness Gauging & Corrosion Mapping.
NDT Inspection Methods Ultrasonic Testing (UT), Magnetic Particle Testing
(MPT), Liquid Penetrant Testing (LPT), Radiographic Testing (RT) Film Interpretation, Visual Testing (VT). Codes, Standards & HSE ASME Sections V & VIII, AWS, Bureau Veritas & KOC QHSSE Policies, Permit to Work (PTW)
Procedures, 24/7 Emergency Callout & Shutdown
Support.
Reporting & Software LDAR Component Database Management, Daily Electronic Activity Reporting, 15-Day Cycle & 30-Day Monthly Reporting, Repair Work Order Issuance,
P&ID Verification, MS Office Suite.
Latheesh Chandran — Curriculum Vitae (LDAR & NDT) Page 1 of 3 CERTIFICATIONS & ACADEMIC QUALIFICATIONS
ASNT Level II Certified: Ultrasonic Testing (UT), Radiographic Testing (RT), Liquid Penetrant Testing
(PT), and Magnetic Particle Testing (MT).
Diploma in Mechanical Engineering (D.M.E.)
PROFESSIONAL EXPERIENCE
International Inspection Centre W.L.L (INTREX), Kuwait NDT Coordinator / LDAR Support Specialist October 2022 – Present Client / Project: Kuwait Oil Company (KOC) – Piping Inspection Services within Production Facilities (Contract No: 22058088)
Reviewed and verified new and existing P&ID diagrams and piping isometric drawings to confirm identification of all light hydrocarbon and gas service streams, reporting discrepancies to management. Executed leak detection surveys, ultrasonic inspections, and high-precision thickness gauging/corrosion monitoring on plant equipment, relief valves, and gas service lines. Coordinated daily inspection schedules, assigned tasks to assistant technicians, and enforced compliance with client HSE and Permit to Work (PTW) procedures. Compiled monitoring records, tracked repair statuses, assisted maintenance teams with repeated on-site measurements during leak repairs, and submitted daily/periodic inspection reports. International Inspection Centre W.L.L (INTREX), Kuwait NDT Coordinator June 2016 – July 2022
Major Projects: KNPC – JGSK.JV Clean Fuel Project (CFP) KIPIC – SAIPEM ESSAR JV (Al-Zour Refinery Project) KOC – GC-32 Project
Supervised multi-discipline NDT teams, conducted daily toolbox talks, and allocated inspection routes and tasks according to daily refinery and field schedules. Monitored and witnessed UT, MPT, PT, and RT activities, ensuring full adherence to project specifications, ASME codes, and quality assurance standards.
Reviewed and approved NDT inspection reports, hardness test reports (Proceq Equotip), and post-weld heat treatment (PWHT) documentation.
Coordinated closely with client engineers and subcontractors to resolve quality deficiencies, clear inspection backlogs, and support plant shutdown activities. Applus Velosi, Bahrain
NDT Technician June 2013 – June 2015
Major Clients: BAPCO, GPIC, BANAGAS (Bahrain) RasGas & QatarGas (Qatar) Performed extensive ultrasonic thickness surveys, corrosion mapping, and weld inspections on pressure vessels, heat exchangers, boiler drums, and cross-country gas pipelines. Executed specialized non-destructive testing including magnetic particle testing (MPT), dye penetrant testing (LPT), and assisted in heat exchanger tube inspections. Latheesh Chandran — Curriculum Vitae (LDAR & NDT) Page 2 of 3 NBTC Kuwait (Naser M. Al-Baddah & Partner)
NDT Technician April 2011 – May 2013
Major Clients / Projects: KNPC, KOC, Equate Petrochemical Co. (M3 & C3 Projects), Sabiya Power Plant Conducted NDT inspections on high-pressure gas pipelines, process vessels, and structural welds across refinery and petrochemical units.
Handled pre-heating and post-weld heat treatment (PWHT) operations on process piping along with complete quality control documentation.
MAJOR CLIENTS & REFINERIES SERVED
Kuwait Oil Company (KOC) • Kuwait National Petroleum Company (KNPC) • Kuwait Integrated Petroleum Industries Company (KIPIC) • Equate Petrochemical Company • BAPCO & GPIC (Bahrain) • QatarGas & RasGas (Qatar)
PERSONAL & PASSPORT DETAILS
Attribute Details
Date of Birth & Nationality 20/05/1985 Indian
Passport Validity Valid up to 10/06/2034 (Issued in Kuwait) Languages Known English, Malayalam, Hindi, Tamil
Latheesh Chandran — Curriculum Vitae (LDAR & NDT) Page 3 of 3