Post Job Free
Sign in

Facility Operating Engineer with HVAC and BMS Expertise

Location:
Boston, MA
Salary:
90
Posted:
March 29, 2026

Contact this candidate

Resume:

Nino Lamberti

* ********** ******

Everett, Massachusetts 02149

781-***-****

*******@*****.***

EDUCATION:

The Peterson School of Engineering Graduated 1989

** ******** ******

Woburn, MA 01801

. HVAC

. Building Controls

. Pneumatics

Everett High School Graduated 1979

548 Broadway

Everett, MA 02149

PROFESSIONAL EXPERIENCE:

UG2 Engineering March 2025 - Present

Facility Operating Engineer

40 Water Street

Boston, Massachusetts 02109

RESPONSIBILITIES:

. Extensive operating knowledge of the Honeywell Computer System with Burnell Controls Inc. and the

Trane Tracer Ensemble Synchrony Computer System

. Experience with Direct Digital Control Fan Power Boxes and VAV Boxes

. Maintenance of supplemental AC units and condenser water pumps

. Run generators and fire pumps on a monthly basis

. Maintain physical plant, including, the maintenance and repair of pumps, fans, motors, and

the operation of NE Trane Earthwise centra vac chillers, including 1,000 ton and 500 ton machines

. Maintenance of the Camus boilers 4.5 million BTU

. Respond to tenant requests regarding cooling and heating issues

. Air balancing of VAV systems and extensive knowledge of pneumatic controls

. Participate in electrical shut downs and fire pump float testing on an annual basis

. Act as a liaison to ensure contractors are in compliance with the building policies

. Maintaining 4 evapco cooling towers –VFD’s with bray valves

Building Technology Engineers June 1987 - March 2025

Facility Operating Engineer

One and Two International Place

Boston, Massachusetts 02110

RESPONSIBILITIES:

. Adjusted t-stat set points on direct digital control fan power boxes and interior VAV Boxes on BMS systems

. Maintained and repaired supplemental AC units and condenser water pumps

. Held sole responsibility of maintaining the physical plant in a high-rise building, encompassing

eight-two floors and covering two million square feet

. Participated in electrical shut downs and fire pump float testing on an annual basis

. Extensive knowledge of the fire alarm system, including, disabling and enabling the fire alarm and smoke detector points to

allow contractors to work on assigned floors safely without disruption

. Certified by the Boston Fire Department to disable, drain, and refill the sprinkler system

. Performed preventative maintenance on all mechanical equipment

References Furnished Upon Request



Contact this candidate