The Thermo Scientific™ TVA****
Toxic Vapor analyzer is the only
intrinsically safe, portable field
analyzer using both Flame Ionization
Detection (FID) and Photo Ionization
Detection (PID) technologies.
Features
• Dual FID/PID technology
• Bluetooth enabled
• Lightweight and compact design
• Easy to service in the field
• No PC based software required
Introduction
The Thermo Scientific TVA2020 Toxic
Vapor Analyzer is capable of detecting
virtually all organic and inorganic
compounds. The TVA2020 analyzer
can be configured for use in diverse
applications including U.S. EPA Method
21 monitoring, site remediation, landfill
monitoring, and general area surveys.
The TVA2020 analyzer is equipped
with a Flame Ionization Detector to
measure organic compounds with high
sensitivity. The FID technology allows
for a wide dynamic and linear range
that produces stable and repeatable
responses. The analyzer can be
configured with both FID and PID
technology for simultaneous detection
and enhanced analytical capabilities.
This dual configuration is capable of
producing a more rapid reading of organic
and inorganic compounds as opposed
to a single detector technology and
provides more comprehensive gas cover-
age than comparable size devices.
After performing a primary calibration,
the TVA2020 analyzer can be customized
by activating internal logging parameters,
uploading a monitoring route, establish-
ing a bluetooth connection, setting alarm
levels, and activating response factors.
TVA2020 Toxic Vapor Analyzer
Lightweight, intrinsically safe portable FID/PID detector PRODUCT SPECIFICATIONS
Thermo Scientific™
TVA2020 Toxic Vapor Analyzer
Optional bluetooth communication
permits the streaming of concentration
data to a handheld device containing the
LDAR software database, thereby
eliminating the need to transfer files post
monitoring and provide a greater access
to route information.
The TVA2020 analyzer is 21% lighter than
earlier models and more compact than
most FID stand alone instruments. The
lightweight and compact design reduces
fatigue for true portability. In addition, a
variety of options are available such as a
basic or enhanced probe, carrying case,
and hydrogen refill assembly.
Specifications
Accuracy
FID Instrument – 10% of reading or 1.0 ppm, whichever is greater, from 1.0 to 10,000 ppm.
PID Instrument – 20 % of reading or 0.5 ppm, whichever is greater, from 0.5 to 500 ppm.
Repeatability
FID Instrument – 2% at 500 ppm of methane
PID Instrument – 1% at 100 ppm of isobutylene
Linear range
FID Instrument – 1.0 to 50,000 ppm of methane
PID Instrument – 0.5 to 2,000 ppm of isobutylene
Response time
FID Instrument – Less than 3.5 seconds for 90% of final value, using 10,000 ppm of methane
PID Instrument – Less than 3.5 seconds for 90% of final value, using 500 ppm of isobutylene
Sample flow rate 1 liter/minute, nominal, at sample probe inlet Battery
The battery operating time is 10 hours minimum at 0 C (32 F). Fully charged in less than 10 hours.
Hydrogen supply
operating time
10 hours of continuous operation, starting from a cylinder charged up to 15.3 MPa (2200 psi)
Physical dimensions 11.5" 9" 4" (29.2 cm 22.9 cm 10.2 cm) Weight
FID only—9.2 lbs
Dual—9.4 lbs
Minimum detectable limit
The minimum detectable level is defined as seven times the standard deviation of peak-to-peak noise.
FID Instrument - 0.5 ppm of methane
PID Instrument - 0.5 ppm of isobutylene
Lamp life
FID Instrument - Greater than 5,000 hours
PID Instrument - Greater than 2,000 hours, with normal cleaning Data storage interval
Auto mode – 1 per second to 1 per 999 minutes, user selectable VOC or FE Mode – 2 to 30 seconds, user selectable
Relative humidity range 15 – 95%
Find out more at thermofisher.com/tva2020
© 2019 Thermo Fisher Scientific Inc. All rights reserved. All trademarks are the property of Thermo Fisher Scientific and its subsidiaries unless otherwise specified. EPM_TVA2020_DS_0719 Thermo Scientific TVA2020 Toxic Vapor Analyzer Ordering information TVA2020 Toxic Vapor Analyzer
Choose from the following configurations/
options to customize your own TVA2020
Toxic Vapor Analyzer
1. Voltage options
A = 120 VAC 50/60 Hz (NA)
B = 220/240 VAC 50/60 Hz (Europe)
C = 220 VAC 50/60 Hz (China)
2. Detector
3 = Flame Ionization Detection (FID)
4 = Dual configured with FID and
Photo Ionization Detection (PID)
5 = FID (Made in China)
6 = Dual (Made in China)
3. Probes
N = No probe
S = Sampling probe
A = Enhanced Probe
C = Both sampling and enhanced probes
4. Outputs
1 = None
2 = Bluetooth
3 = GPS
4 = Both bluetooth and GPS
5. Shipping
N = None
C = Transportation case
R = Hydrogen refill assembly
B = Case and refill assembly
6. Certification
2 = USA: Class I, Division 1, Groups A,B,C,D T3
Canada: Class I, Zone 1, Ex db ib IIC T3 Gb
ATEX: CE0359 Ex II 2 G Ex db ib IIC T3 Gb
IECEx: Ex db ib IIC T3 Gb
3 = NEPSI / IECEx (Made in China-Chinese
Text)
4 = ATEX / IECEx (Made in China-English Text)
Your Order Code: TVA2020 -
To maintain optimal product performance, you need immediate access to experts worldwide, as well as priority status when your air quality equipment needs repair or replacement. We offer comprehensive, flexible support solutions for all phases of the product life cycle. Through predictable, fixed-cost pricing, our services help protect the return on investment and total cost of ownership of your Thermo Scientific products.
USA
27 Forge Parkway
Franklin, MA 02038
Ph: 866-***-****
Fax: 508-***-****
******.***@************.***
India
C/327, TTC Industrial Area
MIDC Pawane
New Mumbai 400 705, India
Ph: +91-22-415*-****
*****@************.***
China
8/F Bldg C of Global Trade Ctr,
No.36, North 3rd Ring Road,
Dong Cheng District
Beijing, China 100013
Ph: +86-10-841*****
****.***.*****@************.***
Europe
Ion Path, Road Three,
Winsford, Cheshire CW73GA UK Ph:
Fax: +44-160*-******
*****.***.**@************.***