Post Job Free
Sign in

Quality Assurance Control

Location:
Pretoria, Gauteng, South Africa
Salary:
R 40 000.00
Posted:
April 09, 2025

Contact this candidate

Resume:

Vereeniging, South-Africa ****

+27-72-581-****

***************@*****.***

PERSONAL SUMMARY

Committed job seeker for a position

in your organization, where I can

deliver my attentive skills to ensure

the Quality work. I have experience

in a variety of practical roles

internationally in Quality Control

and Quality Assurance which is

supported by a strong work ethic

and willingness to learn new skills.

I'm experienced in supervising with

good attention to detail. I am

therefore open to employment

opportunities where my skills and

experience could be considered

useful and transferable. I feel I'll be

a great asset to your team and

company as I have a history of

meeting company needs with

consistent and organized practices.

Skilled in working under pressure

and adapting to new situations and

challenges to best enhance the

organizational brand.

SKILLS

• Welding

• Self-directed mindset

• Project management

• Training and mentoring

• Legal description interpretation

• Measurement collection

Leon Lambrechts

EXPERIENCE

July 2022 - Current

QA/QC Coatings & Corrosion Inspector (Offshore) CLC Inspections & Surveys (Akzo Nobel)

- Conduct:

September 2020 - July 2022

QA/QC 3rd party inspection & Alternative construction supervisor

(Concrete and Coatings) DPA Engineering (Sasol, Secunda) South- Africa

August 2019 - August 2020

QA/QC 3rd party inspection (Coating) M&S Corrosion Control (Sasol, Natref) South-Africa

• Inspection and surveys for whole SBM FPSO fleet offshore:

• Brazil

• Guyana

• Angola

• Equatorial Guinea

• Fabric Maintenance Planning and Management

• Inspection and Survey

• Coating Specification

Conforming to all acceptance criteria via the specification/ method statements to allow wet abrasive blasting before shotcrete and coating to be applied

• Recordings of all environmental conditions

• Recordings of Wet abrasive blasting surface profile (CSP standards)

• Witnessing of shotcrete and coating systems

• Recordings of all DFT's (Coating)

• Witnessing Phenolphthalein & adhesion testing

• Conducting soluble salt tests as required via specification

• Witnessing all core tests conducted

• Signing off on all data packs/ Reports before handing over to client

• Inspection of all scoping (Hammer Test) of cooling tower 245A

• Working at heights

• Material used on project: Concrete & Coatings

• Sika MonoTop 610

• Sika MonoTop 412 NFG

• Sikalastic 152 (Final Top Coat)

Wet Abrasive Blasting grit – Blastrite B90 grit & high pressure water jetting

• Method of application: Shotcrete (Guniting)

Reference: Daniel Ryding, Cell: +27-076-***-****, E-mail: ******@**********.**.**

Conforming to all acceptance criteria via the specification to allow blasting and then coating or lining of all tanks and pipes

• Recordings of all environmental conditions

• Civil engineering background

• Quality control

• Field surveys

• Team leadership

• Verbal/written communication

• Petrochemical

• Quality Assurance

• Engineering

• Piping

• Coatings

• Oil and Gas

• Concrete

November 2019 - February 2020

QA/QC Inspection (Coating) Stefanutti Stocks Durban, South-Africa May 2018 - December 2018

QA/QC Control JVI Services / Mutso Engineering Secunda, South- Africa

• Recordings of blasting surface profile

• Witnessing of coating or lining systems

• Recordings of all DFT's

• Recordings of all dust and debris

• Conducting soluble salt tests as required via the specification

• Signing off on all data packs beforehand overt to client

• Inspection of tank roof tops

• Working at heights

• Material used on project: STONCOR

• Carbozinc 859 (Primer)

• Carboguard 880 (Intermediate)

• Carbothane 134 (Final Top Coat)

• Blasting grit – Ecoblast & Blastrite B60

• Method of application: Conventional spray, Airless Spray Reference: Kobus Oosthuizen, Cell: +27-076-***-****, E-mail: *****@****************.**.**

Conforming to all acceptance criteria via the specification to allow blasting and then coating or lining of all tanks and pipes

• Recordings of all environmental conditions

• Recordings of blasting surface profile

• Witnessing of coating or lining systems

• Recordings of all DFT's

• Recordings of all dust and debris

• Conducting soluble salt tests as required via the specification

• Signing off on all data packs beforehand overt to client

• Inspection of tank roof tops

• Working at heights

• Material used on project: STONCOR

• Carbozinc 859 (Primer)

• Carboguard 193 (Intermediate)

• Carbothane 134 (Final Top Coat)

• Blasting grit – Ecoblast & Blastrite B60

• Method of application: Conventional spray

• Reference: Johan Kriel (Project Manager), Cell: +27-076-***-**** Conforming to all acceptance criteria via the specification to allow blasting and coating of all pipes

• Recordings of all environmental conditions

• Recordings of blasting surface profile

• Witnessing of coating system application on all flanges and spools

• Recordings of all DFT's

• Recordings of all dust and debris

• Conducting soluble salt tests as required via the specification Completion of all coating data packs (ISO's), before hand over and signing off final inspection for release and delivery to site

• Application method of paint by conventional spray Coordinating and managing of x1 team of 16 personals for the production line and quality

• Welding experience

March 2018 - April 2018

QC Control Redec Vilanculos, Mozambique

August 2016 - February 2018

QA/Quality Control Technician ATB Riva Calzoni Mozambique

• Visual inspection of the welding conducted

To confirm that weld conforms to the welding specification before coating can continue

• Material used on project: STONCOR

• Carbozinc 11 (Primer)

• Carbozinc 859 (Primer)

• Carboline 193 (Intermediate)

• Carbothane 134 (Final Top Coat)

• Blasting grit – Ecoblast & Blastrite B60

• Method of application: Conventional spray

Reference: Johann Viljoen, Cell: +27-82-855-****, E-mail: ******@***********.**.**

Conforming to all acceptance criteria via the specification to allow all sites to be coated

• Recordings of all environmental conditions

Witnessing of x3 coating system application on all welds, flanges and spools

• Recordings of all DFT's

• Completion of all painting data packs, before hand over

• Application method of paint by brush & roller

• Welding experience

• No welding responsibilities

• Only coating

All blasting and 1st coat (Primer) applied in workshop, Vanderbiljpark – Gauteng

• Material used on project: STONCOR

• Carbozinc 859 (Primer)

• Carboguard 193 (Intermediate)

• Carbothane 134 (Top Coat)

• Carbomastic 186 (Primer/Intermediate) used on site Reference: Louis Storm, Cell: +27-82-317-****, E-mail: *****@*****.**.**

Comprehensive Inspector representing ATB Riva Calzoni Contracting on the Massingir Dam water scheme project (Mozambique)

Witnessing and acceptance of Non-Destructive Testing and Destructive testing

• Inspection of welds and joints and internal linings via the QCP

• Witnessing welding via the WPS

• Assisting with TOFD

• Dye Pen Testing and MPI

• Fit up and alignment before welding commences

• Coordinating of x3 technicians

• Quality control of all documentation and data packs

• Signing off before handing over to client

• Experience: Coating systems and their application methods

• Destructive and Non-Destructive Coating tests and test procedures Good understanding and utilization of Coating thickness equipment and its limitations

• Inspection reporting

February 2014 - August 2016

Quality Control Technician Sonartech South-Africa

• Familiar with ISO, SSPC, NACE, ASTM, Codes and Standards

• Basic understanding of cathodic protection

• Co-ordination, supervision and planning

• Supervision of beveling preparation before fitting up

• Supervision of welding joints preparation

Supervision of piping fit up before welding according to the approved drawing

• Supervision of the WPS correct parameters during the welding activities

• Visual inspections to mark out defects

• Monitor repair process

• Wall thickness measurements on parent material

• Monitor consumables storage and usage

Skilled and understanding, but no certification in: Dye Pen testing, MPI, TOFD

Material used on project: Jotun – Jotamastic 87 & 90, Jotun – Hard Top Flexi

• Airless Spray

Reference: Luca Donadei, Cell: +39-338-***-****, E-mail: ****.*******@*****.***

Quality control of the whole project for external, internal work regarding coating and lining of all pipes

• Flanges, joints, Air valves and crotch plates

• Destructive testing and non-destructive testing

Monthly, weekly and daily planning with production to achieve progress targets

Managing of X3 groups with 8 people in a group for different sections with x3 super visors

All coating and lining documentation and signing of reports before handing over to the client

Material used on project: Sigma 523 & Sigma 588, Poly clad 777, Denso Primer, Bitumen Wrap

• Reference: Mervyn Shaw, Cell: 072-***-****

EDUCATION

June 2006

General Management Course Introduction to economics and management environment, Language and learning skills Unisa, South-Africa

January 2001

1st Year in Sport Management

Potchefstroom University, South-Africa

January 2000

Grade 12 / Matric Afrikaans, English, Mathematics, Geography, Economy and Accounting

Pietersburg High School, South-Africa

ACTIVITIES AND HONORS

• I play squash

• I workout

• I swim

CERTIFICATIONS

- NACE CIP Level 1 & 2 – Certified

- ISO 12944 Certificate - Certified

- Corrodere Academy – Coating Survey Level 1 - Certified

- BOSIET & CA-EBS – Certified

- PSSR – Certificate nr 24-07 And PSSR-74070 - Certified

- Personal Survival Techniques – Cert nr 24-07-PST-74176 - Certified

- CSWIP 3.1 Level 2 course attended 19th May 2017

- CBT Legal Liability OHSA - Certified 2021

- Working at Heights - Certified 2022

- Accident & Investigation – Certified 2021

- Effective contractor management – Certified 2021

- Planned task observation – Certified 2022

- OHS Act for management – Certified 2022

- OGUK Medical – Expires 05/06/2025

LANGUAGES

Afrikaans: First Language

English: C2

Proficient (C2)

Portuguese: A1

Beginner (A1)



Contact this candidate