Post Job Free

Resume

Sign in

Power System Protection Engineer

Location:
Kuala Lumpur, 50000, Malaysia
Posted:
September 24, 2023

Contact this candidate

Resume:

Omar Salah Elsayed Atwa Resume

* * * * *

002*********** 002***********\+601*********

adzwpq@r.postjobfree.com adzwpq@r.postjobfree.com

-Malaysia,kuala lumpur,basngar south

-14 Selem Street of King Faisal Strret, Al jiza, Cairo, Egypt Professional Summary

-Skills in managing / maintaining building / site electrical systems

-Electrical power, equipment and instrumentation and energy management experience.

-Power Stations and Substation construction, testing and commissioning about 30 years Experience.

-PSG (Power System Group) IEEE-Paper Reviewer-Volunteer-US since 2008,

-Innovative Smart Grid Technologies-ISGT-IEEE- Paper Reviewer-Volunteer-US-Since 2015

- The author of Practical Power System and Protective Relays Commissioning Book published in the Elsevier US Last May 2019 Elsevier

Skills

Windows, MS Office, Internet

Power system studies

Relay setting Calculations

Testing and commissioning managements

High Voltage Substations

Power stations Facilities

Power system Technical Writing

Experience

-Lead Protection engineer in a lead windfarm company 2022 Technical advice of all power system protection aspects, and project deliverables.

-Lead technical advice protection engineer, Tengiz oil and gas field refinery, Kazakhstan, Chevron Company 2022

-commissioning of GE units protection.

Electrical Consultant, Freelance, 2019-2021

Power stations and Substation construction, testing and commissioning about 30 years Experience in Cairo, Egypt and international,Saudi,UAE,Ireland UK,Australia,Indonesia,Libia,Kiwaut,different projects, including jobs as freelance Principal Protection Engineer/Commissioning Manager/Design Manager The Omar Salah Elsayed Atwa Resume

2 P a g e

service including Design Review of Protection System for Generation and Substation, Relay Setting, Testing and commissioning,AIS,GIS,Protection Relays of Different Types. Power System Distribution Specialist, 2018-2019

In Indonesia for a April Group –Riau Power Energy Company(RPE),Paper Mill ProductionPangklan Kerinci,Indonesia-Paper and pulp producer, round 700MW power station,150kV,33kV,20kV Swithgears,Many power and service transformers 150/20kv,20/0.690kV and 20/0.4kV,Giveing advice and consultation as specialist in protective relays of power system studies, electrical maintenance of Steam and Gas turbines protections, AIS and ABB GIS 150/33/20 kV Switchgear, protection relays testing and setting calculations The services including: Design Review of Protection System for Generation and Substation, Relay setting, Testing and commissioning, AIS, GIS, Protection Relays different types and different makes,siemens,ABB,also review power system study for the mill from Poyry and Siemens consulting offices.

Electrical Consultant, 2015-2018

-In Cairo Egypt, Ireland and Oman Different Projects, including Testing and Commissioning and Design Review, Relay Setting Calculations.

Protection & Commissioning Team Leader, TLI Group Ireland, 2015- 2015

-Testing and commissioning of 220/110KV substation, 110KV GIS Switchgear is ABB ELK-04, 220KV GIS Switchgear is ABB ELK-14C,220/110KV, coupling transformers are CG Power 250MVA, protection and Control systems including using Omicron 356 test set version 3.0 and Siemens software Degsi 4.8, Over current Relays Type 7SJ611 and Distance Protection 7SA612, Busbar Differential/CBF relay is a Toshiba GRB100, Substation 220KV Sync scheme is a Synchrotact 5, Control System is a Siemens SAT250, Trafo differential relays are ABB RET670 by using Software PCM 600 also Commissioning programming and commissioning management and Resources planning. The customer was ESB Ireland Electrical Consultant, 2012-2015

-In Cairo Egypt, Ireland and Oman Different Projects, including Testing and Commissioning and Design Review, Relay Setting Calculations.

Substation Commissioning Manager GHD Consultant –Australia, 2011-2012

-In North Australia, Darwin City Manage commissioning activities at sites. Prepare testing plans. Commissioning schedules. Coordinate with stakeholders the testing activities. Attend commissioning panel meetings. 66KV Siemens GIS Testing witnessing in behave of Power Water Electrical Company North Australia.

Site Commissioning Manager, ABB UAE, 2011-2011

Eskan Abu Dhabi 132/33KV S/S-Fewa Rass Al Khema UAE 5 substations 132/33KV Supervise and manage commissioning activities, MST, commissioning team at site, this includes the following:-Manage a group of Sir-protection and commissioning engineers (about 20 engineers). -Prepare the overall commissioning program for substations to ADDC and FEWA. Prepare three weeks commissioning schedule.-Follow all commissioning activities in substation and interface work with All subcontractors. Including ABB GIS, ABB Protection Relays and ABB SCMS. Prepare Commissioning Method Statements Omar Salah Elsayed Atwa Resume

3 P a g e

as required for busbar Protection Upgrading. Manage the cost of manpower resources based on the project Requirements.

Senior Consultant Protection Engineer, Mott MacDonald Group Abou Dhabi, 2009 -2010

Sadyat Island 4 substation 132/22KV and one grid station – Abu Dhabi Commissioning Resident Engineer at Saadiyat Island following the Commissioning activities of 132/22KV Substation Protection System –Siemens Busbar Protection Type 7SS522/7SS523, Siemens Transformer Protection 7UT 513, 7SJ612, Feeder Line Protection 7SD522 and other Substation commissioning activities including GIS132KV, GIS 22KV and 132/22KV Transformers. Commissioning of Substation Control System Siemens-SICAM PAS- 6MD9. Commissioning of ABB Busbar Protection Type REB 500. Electrical Commissioning Team Leader ABB UK, 2007-2009 National Grid upgrading of protection system in central UK-Nicap-2,South Manchester Substation protection relays settings (Commissioning Management Relay Setting Approved Engineer TP141) Commissioning activities for 400 & 275KV substations including Producing test sheets for NG protection such as RED670, REC561, P545 Relays in power system division, also producing the relay setting Calculations for NG (TP 141 Relay Setting Engineer Authorizations). Assist the Commissioning Manager in the co-ordination and Management of company commissioning process (NICAP 2 project - West Burton AIS 400KV Project - South Manchester 275KV Alliance Project). Carry out fault level and protection setting - TP 141 Relay setting Authorization include Nicap 2 Relay setting, West Burton EDF Busbar Protection and Backup Directional relay for generating units, south Manchester 275/132KV Mesh corners, SGT Protection, High Impedance Busbar Protection Calculations. Up loading of Setting Sheets

(MARS) And Relay Configuration Files to NGT Live Link System. Produce NGT Thermal Rating Sheets, Protection DAR schedules. Produce NGT Switching Programs. Protection Engineer, Saudi Electric Company Western Region, GTS, 2006-2007 The Job includes the following Power Stations in West of Saudi Arabia: SHOAIBA Power Plant 7x393MW Jeddah Power Plant GT units Rabigh Power Plant ST units, GT units and CCST units Madinah & Yanbu Power Plants 6x205MW, 2x30MW, 3x45MW GT units TABOUK Power Plant, GT units Provide Technical expertise to review, update & unify Protection Maintenance procedures & standards across West Generation Region in Kingdom of Saudi Arabia. Review system disturbances & investigation all protection mis- Operations. Provide bi-weekly report to SEC Technical Service Manager; perform Related duties as assigned by the SEC Technical Service Manager. Include Generator, Step-Up Transformer Protections such As REG-216 From ABB also Multilin DGP and G60 from GE and Micom342 from Areva, 7UM61 from Siemens and other classical Static Relays from BBC Generator Protection and induction type from GE.

Senior Transmission & Maintenance Protection Engineer, Dubai Electricity & Water Authority, DEWA, 2005-2006

Testing and supervision of Protective Relays of different types for Feeders, Transformers, Busbars 400KV and 132KV systems use the More recent test equipments as Omicron, FRIJA 300. Review system disturbances & investigation all protection mis-Operations. Work with Area Protection Staff to review protection coordination issues, Provide training & guidance to all Protection Maintenance Staff. Provide Omar Salah Elsayed Atwa Resume

4 P a g e

bi-weekly report to DEWA Protection maintenance Manager; Perform related duties as assigned by the DEWA Protection Maintenance Manager.

Senior Project Protection Engineer, Toshiba/MITSUI Co, 2002-2004 Managed all drawings submission and approval with the customer SEC-CRB and fully coordinated with subcontractors ABB Saudi and SST Company, including all site activities supervision and remote end Protection modifications at 17 Remote Ends Substations. Provided technical negotiations with the customers, with full knowledge of international standard of protection relays and customer Specifications. Followed up of protection relays commissioning for the main substation and remote end substations. Senior Protection/Commissioning Engineer SIEMENS, Egypt, 2001-2002 Commissioning Protection Engineer for PT, CT, Control Circuit, Tap,Change control, power transformer testing, interface circuit for power,Transformer 220/33KV in Al Ezz factory for steel in Suez Gulf in Egypt.,Commissioning of distance relay Siemens make type 7SA513, Alstom,Make type EPAC 220KV lines in Libya.

Senior Design Protection Engineer, SIEMENS-WESTINGHOUSE, 1999-2001 Project with SCECO-E (Saudi Electric Company at Eastern region-Saudi Arabia) for modification of protection Schemes of replacement of distance relays in 3 S/S and phase Comparisons relay replacement with line differential relay type LFCB Alstom made. The project also covered distance relay settings, C.T. and P.T. sizing, SCADA point list, SOE point list, Fault Recorder point list, Single line Diagram, relay and control line diagram and testing and commissioning of the protective relays. Site Manager, SIEMENS AG,Egypt, 1998-1999

Malawi West S/S 220/66/33/11KV-Coustomer-EEA The scope of work covered complete installation and testing of S/S.

Commissioning Engineer CEGELEC, 1996-1998

Commissioning of Taba S/S 500/400/220/22KV (interconnection cable Between Egypt and Jordan) GEC Alstom Relays. Commissioning of Luxor S/S 220/66/11KV GEC Alstom Relays. Commissioning Engineer ISCOSA, SIEMENS WESTINGHOUSE,1995-1996 Covered the following job sites:

King Saudi University S/S protective relays. Modification and installation of directional over current relays and i.e. relays of 69KV grid station for SCECO-E in Saudi Arabia. Commissioning relays of gas turbine generators for low Rate radar base, Panesma Co. for Saudi Air Force. Westinghouse Kuwait (Head Office in Orlando USA). Project for Sabah El Salam ‘C’ S/S GIS SF6 132/69/11KV. Complete Testing and energization of S/S (Reyrole protections, GEC busbar Protection MBCZ 10). Omar Salah Elsayed Atwa Resume

5 P a g e

Protection Commissioning &Maintenance Engineer, Egyptian Electricity Authority

(E.E.A),Protection Maintenance Department

Cairo North I Combined Cycle Project (750MW), including all Switchgears, MCC, GIS, Batteries, Unit Transformers and Station Transformers, Scada Systems. Cairo West Thermal Power Plant 2x350MW, including all Switchgears, MCC, GIS, Batteries, PS, Unit Transformers and Station Transformers, Scada Systems. Provided supervision, installation and commissioning of power stations And substations protective relay and control systems. Basaten S/S extension third transformer 220/66/11 as representative of E.E.A. for testing and commissioning. Abu Zabal 500/220KV Mitsubishi made GEC relays. Bahtem S/S extension for the third transformer AEG made, Cairo North. Provide Technical expertise to review, update & unify Protection Maintenance procedures & standards across Cairo Electricity Zone in Transmission system. Review system disturbances & investigation all protection mis- Operations. With Area Protection Staff to review protection coordination issues; Provide training & guidance to all Protection Maintenance Staff. Work with Technical Institutes to ensure Protection Trainees follow latest Standards & procedures Provide bi-weekly report to Protection Maintenance Manager; perform related duties as assigned by the Protection Maintenance Manager. Education

-IET UK Membership IMET Since 2007

-M.SC Degree In Power System Protection

Cairo University, 1990-1995

-B.Sc Degree In Electrical Power and Equipments

Menofia University, 1983-1988

Accomplishments and Certificates

-Project Management Professional Course 2015

-Course in Protective Relays by Jack Royals and Steve Pickering Alstom- GEC (1994).

-Course in Protective Relays 66/11KV Substation and Busbar Protection RADSS-ABB made by ELECTROIMPEX Co. in Sofia – Bulgaria (1994).

-Course in Protective Relays, Cairo University (1994).

-Avantis.pro training course for CMMS (Computerized Management Maintenance System) for two weeks in Jeddah – Saudi Arabia (2006).

-CDM training, UK by SAFTY & RISK MANAGEMENT (Sep. 2007).

-Construction Design Management Regulation UK (Mar. 2008).

-Safety Rules Training by NG UK Leeds (Mar. 2009). Omar Salah Elsayed Atwa Resume

6 P a g e

-TP 141 Relay Setting Authorization UK Leeds (from 2008 valid up to 2011).

-Personal Training UK NGT EAK 17599 Energy Utility Skills Register EUSR ID EUSR105474 up to Apr. 2011.

-A course in PCM600 2.3, RED 670, RET 670, REB500 ABB Sweden at Dubai (Apr. /May 2011).

-EDSA Software for Power System Load flow and protection coordination.

-ETAP POWER STATION 12.0



Contact this candidate