EXECUTIVE PROFILE
** ***** ** ********** ** Maintenance of Oil & Gas, Power & Desalination and chemical plants.
A dedicated team player with ability to build excellent inter-personal relations.
Resourceful with excellent analytical, problem solving and decision making skills.
Possess experience to work efficiently in a fast-pace, professional environment.
Strong work ethics, multi-tasking, excellent correspondence, communication & coordination skills.
EDUCATIONAL QUALIFICATION
3 Years Bachelor in Electrical and Electronics Engineering. Year-March 2007.
Sathyabama University,Chennai, India.
3 Years Diploma in Electrical and Electronics Engineering. Year-March 2004.
Velankanni Polytechnic, Villupuram, India.
Good knowledge in AUTOCAD and MS office package.
WORK EXPERIENCE
Organization : QATAR LIQUEFIED GAS OPERATING COMPANY LTD (QATARGAS), RAS-LAFFAN, QATAR.
Designation : LEAD ELECTRICAL TECHNICIAN. (CEP)
Tenure : 10th April 2011 to still.
Reporting to : Foreman and supervisor
In Qatar Gas LNG plant Worked in the following areas:-
LNG process trains : 2 x 7.5 million metric tons per annum.
Utility power generation : 2 x 33 MW 11KV Gas turbines Generator.
: 3 x 43 MW 11 KV Steam turbines Generator.
: 2 x 55 MVA 11/66 KV, 3 x 58 MVA 11/66 KV,
4 x 112 MVA with OLTC 66/33 KV, 10 x 30 MVA
33/6.6 KV, 4 x 5 MW Emergency diesel generator.
JOB DESCRIPTION:
Involved with the Maintenance group to carryout maintenance as per planning schedule and breakdown maintenance as per work orders in the Gas Receiving Area, Utilities, Process Plant, Tank Farm and Loading Jetty’s.
Familiarized in Qatar Gas Electrical Safety Policies and Procedures and Authorized to CEP (Competent Electrical Person) level to perform Low Voltage Switching, isolation and De-Isolation within the Electrical Safety Rules.
Got familiarized in Hazardous area Classification and Applicable Codes and Standards.
Familiar with ELIECS (electrical integrated control system), EPDCS (essential power distributed control system, PMS (power management system), DCS (distributed control system).
Have considerable experience in construction, testing, commissioning and startup of electrical equipment’s. Like inspection for construction activity, walk down and punch list preparation.
Transformer testing, transformer alarm and trip testing, stability test for 87L, 87T, ATS function test for switch gear incomers, oltc runthrough test,ctr troubleshooting,online monitoring for motor,earth pit resisance,earth loop impeadence for cable, relay testing as per check sheet, LCS function test, LV and MV motor solo run test, cable hi-pot test, ELIECS i/o test, Generator protection test, HVAC function test, Battery charging discharging test, IR test.
Equipment’s handled:
Distribution Transformers 11kv/66kv, 66kv/33kv, 33kv/6.6kv, 6.6kv/440v make ABB of various capacities.
11kv Gas turbine generator (33 MW) make by GE Energy, 11kv Steam turbine generator (43MW) make by MITSUBISHI and 11kv - 5MW Diesel generator make by AVK.
HT Motors (6.6kv- Capacity 390kw to 3.2 mw) make by ABB type of Explosion proof, LT Motor, DC Motors, and Auxiliaries motors for Gas Turbine driven Generators.
Heat tracing system
Cathode Protection Transformers.
Motor Operated Valves Rotorqe Make.
Switch Gears:
Panels
66kv SIEMENS – Metal Clad SF6 Gas Insulated Switchgear.
33kv SIEMENS – Metal Clad SF6 Gas Insulated Switchgear.
6.6kv ABB Korea- Metal enclosed switch gear.
415v ABB Malaysia Switchgear with INSUM MCU2 motor Management system
Breakers
66kv, 33kv SIEMENS SF6 Breakers and Contractors.
6.6kv ABB vacuum circuit breakers and Contractors.
415 v ABB air circuit breakers and Molded case circuit breakers.
Protection System
Protective Relays ABB REF542plus integrated multifunctional device for transformer protection and SIEMENS SOLKAR relay and for 87T protection.
Protective Relays ABB REM543 microprocessor-based relay for MV motor protection.
Protective Relays GE SR489 generator management relay for Generator protection.
UPS Systems and Battery Charger System of Make GUTOR.
Protective Relays SIEMENS SIPROTEC for 87L protection
Organization : ACWA POWER BARKA S.A.O.G. OMAN.
Designation : Electrical Technician.
Tenure : 29th October 2007 to 28th March 2011.
Reporting to : Electrical Engineer (Operation & Maintenance).
ACWA POWER BARKA S.A.O.G. is the Power & Desalination Station, Power Generation (456 MW) & desalination Station (20 MIPGD).
JOB DESCRIPTION:
I worked as Technician – Electrical, in this 456 MW Power Station & 20 MIPGD Desalination Station. Combined cycle Power Station comprising of Two (2) numbers of V94.2 Gas Turbines & One (1) Steam Turbine of ANSALDO make and Three Desalination units each having a capacity 6.67 MPIGD of HITACHI make.
Equipment’s handled:
Responsible for the Power Station & Desalination Station Operation & Maintenance of all SIEMENS / ABB / TOGAMI Make: MV(11KV) & LV(415V) Switchgears
GUTOR Make: Battery chargers & Battery Banks of 220V & 110V DC, Inverters (240V AC)
ANSALDO Generators (2 X 159 MVA, 15.75 KV & 1 X 280 MVA,19KV)
ABB Make: Generator Transformers(280 / 210 MVA, 225/19KV & 159/120 MVA, 225 /15.75 KV)
ABB Make: Unit Transformers (55/44MVA, 15.75/11KV),OCERVE Make: Auxiliary Transformers(1MVA, 11/0.415KV),15.75 KV, 19KV GCB(s) : ABB Make (Type HGC 3 & HEC 3) 11 KV & 415V VCB’s & ACB’s of SIEMENS / ABB / TERASAKI Make, Various Protection
Relays of Make: SIEMENS / ABB / MITSUBISHI / ALSTOM / AREVA- MICOM,Motor(s) (11 & 0.415 KV) of ANSALDO / ABB / SIEMENS / WEG make, MOV of Make: AUMA and Navigational buoys, Make: TIDE LAND.
TESTING INSTRUMENTS:
Having proficiency in using the following testing instruments:
Digital low resistance ohm meter (DLRO) (Make: AVO - Biddle instruments)
Megger (Model: BM223 & BM25) Make: AVO Megger Test kit
Earth leakage clamp meter (Model: DCM 300E) Make: AVO Megger
Ground loop tester (Make: HEME GEO 15)
Power quality meter (Make: MEGGER) – (MODEL NO: DCM 1000P)
Secondary injection test kit (Make: AVO Pulsar universal test system )
Clamp meter (Make: AVO MEGGER) – (MODEL NO: DCM 2039)
Earth tester: (MODEL: DET4TCR2 + KIT 2,3 & 4 terminal earth tester)
(Make: Megger UK).
Planning the Schedule for maintenance activities of the Power Station & Desalination
Station electrical equipments such as Switch Gears, Motors, Transformers, etc.
PERSONAL DETAILS
Date of Birth : 26th May 1983
Sex : Male
Languages Known : English, Hindi and Tamil
Fathers Name : Arumugam
Mothers Name : Jothi
Nationality : Indian
Passport No. : P0491461
References : Depending on Request.