Post Job Free
Sign in

Hvac Technician Foreman

Location:
Doha, Qatar
Posted:
April 08, 2023

Contact this candidate

Resume:

Curriculam vitea

Anil Kumar bharti

Permanent Address: Vill+post salahabad distric mau 275101 u.p.(india) present Address: Al barwa labour camp 52 qatar

Skype ID. ************@*******.***

E-mail *************@*****.***

Mobile: +974-********

Nationality: Indian +918*********

Notice Period: One Month

Profile / Date of Birth: Male, Married / 10 Oct/1981 Passport No.: K8086130 (Valid till 12 August 2024) Salary Expectation: Negotiable

Prefered Locaion: (QATAR)

QUALIFICATION:

• Diploma in Refrigration and Air condition from Akash Technical Degree College UP.

• Secondary School Education from UP Board .

POSITION APPLY FOR HVAC CHILLER Supervisor OR foreman PROFESSIONAL SUMMARY:

Exceptionally dependable and well-trained Chiller Foreman with 15 Years experience and a variety of system specializations in Maintance and Project and FM.Having all experience in all kind of HVAC system centralizated air condition with air cooled chiller and water cooled chiller . CARRIER ACHIEVEMENTS:

• Managing operation and Maintanance of Air Cooled, Water cooled Chiller Named Trane,YORK,Carrier,Mcway, upto the Capacity of 30 to 400TR..To 2000 Tr

• Deep Knowledge of Chiller Troubleshooting,Chiller Operation,Chiller maintance and Repair along with PPM and CM.

• Deep Knowledge of controlling and wiring of Star Delta,V Star,Delta Part vending of Motor

(220-440V).

• Troubleshooting, Maintanance,Overhauling, Repairing and Commissioning of Reciprocating Compressor(Semi sealed,Sealed Type),Scrol Compressor,Screw Compressor,Centrifugal Compressor,Rotary Compressor.

• Maintanance and Repairing of Primary Pump,Secondary Pump,Thersary Pump and Make up water Pump, Condensor Pump.(Bearing Replacement,Sealed replacement,balancing and Alignment and Greesing )

• BMS Operation .

• Installation testing Commsioning Maintance and Repairing of collin tower AHU,FAHU,FCU,Heat Exchanger,Exhuast Fan,Pressurization Fan,Smoke Fan, Ductable AC, Package AC,DX unit,Cassete Unit and Split Unit,Floor Standing AC. Working Experience: Total work experience of 15 years with 7 years in Middle East Gulf

Company name: New Technic group

Project Handing : Sewa Bech resort & vills ( Hillton Engineering) Designation. : Chiller plants supervisor

Department. : Engeniaring

Duration. : 27 April 2022 till now

Location. : Qatar

Company Name : ENGIE Cofely Mannai Facility Management Project Handling : West Bay Tower 44,ECCH ( Qatar foundation) Designation : Chiller/HVAC Foreman

Department : Operations & Maintenance / Facilities Management Duration : Dec 2016 to 26 April 2022 Location

: Doha, Qatar

Company Name : BAHRAIN ELECTROMECHNICAL CO.

Designation : Sr. HVAC Chiller Technician

Project Handled : SHIFF TOWER & MALLS,WORLD TRADE CENTRE. Department : Facility Management

Duration : 18JAN 2014– 11FEB 2016

Location : BAHRAIN

Company Name : SIDESH AIRCONDITION COMPANY THANE INDIA Designation : HVAC CHILLER TECHNICIAN

Department : PROJECT & FACILITY MANAGEMENT

Duration : JAN 2011 – DEC 2013

Location : INDIA

Company Name : LARSEN TOURBO ELECTROMECHNICAL LLC OMAN Designation : HVAC CHILLER TECHNICIAN

Project Handled : Ministy Of Defence

Department : FACILITY MANAGEMENT

Duration : MAY 2007 8 DEC 2010

Location : OMAN

Company Name : BLUE STAR LIMITED DELHI

Designation : HVAC TECHNICIAN

Department : Installation Testing and Commision

Duration : May 2004 7 Feb 2007

Company Name : VIGNESHWAR AIRCONDITIONING PVT LTD

Designation : AC TECHNICIAN

Department : Installation Testing and Commision Duration Jan-2003–March- 2004..

Location:India

NATURE OF JOB

• Managing operation and Maintanance of Air cooled Chiller Named Trane,YORK,Carrier,Mcway, upto the Capacity of 30 to 400TR.

• MAINTENANCE AND REPAIRING OF WATER COOLED CHILLER UPTO THE CAPACITY OF 500- 2000TR • INSTALLATION TESTING AND COMMISSIONING OF PACKAGE MACHINE WITH THE CAPACITY OF 5TR-20TR.

• MAINTENANCE AND REPAIRING DUCTABLE UNIT UPTO THE CAPACITY OF 5TR-15TR.

• PPM AND CM WORK COLLING TOWER AHU AND FAHU AND FCU WITH USING PROPER PPE AND ISOLATION TAG.

• OPERATION AND MAINTENANCE OF COOLING TOWER.

• ALL KIND OF BRAZING WORK FOR COPPER TO COPPER AND COPPER TO OTHER METEL.

• CLEANED CONDENSER COILS, CHECKED ALL OPERATIONAL AND SAFETY CONTROLS, CHECKED SUCTION AND DISCHARGES PRESSURE, CHECKED FOR REFRIGERANT LEAKS, SILVER SOLDERED AND SILVER BRAZED ALL BREAKS, EVACUATED AND RECHARGED SYSTEM.

• IDENTIFY T

• HE GAS LEAKAGE USE REFREGRENT LEAKAGE DETECTOR MACHINE IN THE CONDENSOR UNIT.

• ATTENDING OF ALL BREAKDOWN CALL AND EMERGENCY CALL.

• OPERATION MAINTENANCE AND REPARING OF PRIMARY PUMP,SECONDARY PUMP AND CONDENSOR PUMP.

• OPERATION OF VFD PANELS WITH ATTENDING CM JOBS.

• OPERATION, MAINTENANCE AND REPAIRING OF ALL TYPES OF FAN (EXHUAST FAN,SMOKE FAN,VENTILATION FAN,AND PRESSURIZATION FAN).

• BASIC CALCULATION OF HEAT LOAD AREA,AIR BALANCING OF SYSTEM,KNOWLEDGE OF THERMAL INSULATION WORK FOR DUCTING .

Name :Anil Kumar Bharti

Signature :

Date :



Contact this candidate