Objective

To obtain a challenging position requiring strong organizational and leadership skills, good work ethic, and attention to detail.

Experience

2011-2022 Hines 1585 Broadway NY, NY

Engineer Manager

Day to Day operations. Preventive maintenance programs, Utility budgets, Annual Budgets and month to month variances.

Coordinate all of Morgan Stanley critical maintenance and Critical Shutdowns involving 29 ATS, 26 MTS, 40 Liebert PDU’S Two MGE 1000 KW parallel redundant UPS systems. Two MGE 1350 KW parallel redundant UPS systems Two APC 400 KW UPS system. Five Mitsubishi 1600 KW generators, One 1400 KW Caterpillar life safety generator. Diesel fuel reserve containing 24,000 gallons. Asco parallel switchgear.

Capital improvements - consisting of installation of a new 1600 KW Mitsubishi generator, Installation of three new Asco ATS, Installation of new 1200 emergency bus riser, Replacement of 10 Asco MTS, Replacement of 20 Liebert PDU,

Installation of new MGE UPS 1350 kW parallel system.

Installation of two Carrier 1600 ton chillers, One SMARDT 1000 ton chiller, and all isolation valves 78 total. Five new condenser water pumps, five chiller water pumps, all new VFD’s, while maintaining critical active communication rooms.

Tenant buildout of floors 10-27 400,000 square feet +

New amenities area café and fitness center.

2009–2011 Hines 522 5th avenue

Engineer Manager

Created preventive maintenance program to ensure maximum life, reliability and efficiency of all property mechanical systems.

Oversaw installation of new York 900 Ton Chiller, replacement of all chilled water and condenser water pumps and new VFD’s

Planning and implementation of Building Management System including development of an extensive recommended points list to final commissioning.

Launched Efficient Practices to develop staff involving Energy anagement, IAQ, Utility tracking, Refrigerant Management, Safety training, Chiller performance, Contingency plan/ Critical spare parts program.

2007–2009 Hines Interest One Pierpont plaza, NY, NY

Chief Engineer

Implementing and accounting for all preventive maintenance for base building and Morgan Stanley.

Daily supervision of tenant request and scheduling repairs in a timely fashion.

Coordinate all of Morgan Stanley critical maintenance and Critical Shutdowns involving data center and UPS systems

Coordinate Base Building Critical Shutdowns.

1998–2007 Hines Interest 1585 Broadway, NY, NY

Engineer / Assistant Chief

Operating Chiller Plant consisting of 6 Chillers with 5150 tons of cooling capacity. Chilled water system feeding 17 Buffalo Forge VPS fans and 3 secondary PFHX providing condition air to eight communication rooms.

Perform preventative and proactive maintenance

Providing immediate house-call service to tenants regarding various problems.

Education

1993–1994 Turner Refrigeration West 45th Street, NY, NY

Completion Of Local 94 Apprenticeship program

Licenses and Certificates

BA business communication Suny Albamy

NYC Refrigeration License

OSHA 10. OSHA 30

D.E.C pesticide certificate, sub-catorcory 7G

USGBC Leed AP

Additional Training Courses Completed

Powerware UPS Maintenance School S3000 1st Responder

Asco 962 Advanced Training Seminar

Advanced Insight 5-105

Advanced Apogee systems 5-625

Liebert Global Services Sitescan/Alert Training

Liebert SOE1 Environmental Training

Trane Centrivac Preventive Maintenance Seminar

I.U.O.E Water Treatment Course 30 Hours