till
R.TAMILSELVAM BOILER TECHNICIAN
OBJECTIVE
I seek challenging opportunities where I can fully use my skills for the success of the organization. EXPERIENCE
KGS Nelsun paper mill pvt ltd, Thanjavur.
D.M.Plant operator & BOILER OPERATOR
Boiler Reg.no : T/6154
Type :Bi-Drum water tube (AFBC) boiler
Boiler capacity :5000(kg/hr)
Heating surface :189m^2
Feeding system :Over bed feeding System
Used for Fuel : Rice husk,G.N.S, Saw dust
MALAR paper mill pvt ltd., KARAIKUDI .
BOILER OPERATOR & Softener Plant Maintenance
Boiler Reg.no : T/7543
Type :Bi-Drum water tube (AFBC) boiler
Boiler capacity :10000(kg/hr)
Heating surface :248m^2
Feeding System :Under bed feeding system
Used for Fuel : Rice husk, Saw dust
T.V.Sundaram & group of (Tyre) Company pvt Ltd., pudukkottai. BOILER OPERATOR & RO Plant Maintenance
Boiler Reg.no : T/9034
Type :Fire tube boiler (HMT)
Boiler capacity :1000(kg/hr)
Heating surface :39m^2
Used for Fuel : Briquite & wood
SIVAS PAPER MILL Pvt Ltd., KANGEYAM.
BOILER OPERATOR & RO Plant Maintenance
Boiler Reg.no : T/9032
Type : smoke and water tube (wood boiler),
Boiler capacity :6000(kg/hr)
Heating surface :237m^2
Used for Fuel : wood
EDUCATION
Diploma in mechanical engineering and Second class boiler certiļ¬cate in Government of Tamilnadu.
SKILLS
Boiler problem solving skills, Interpersonal skills, Punctuality skills, LANGUAGES
TAMIL and ENGLISH
@
O
*************@*****.***,
S/o K.RENGAN
.218/2,SENTHIRAIPATTI,
POOVARASAKUDI(PO),
ALANGUDI(T.K), PUDUKKOTTAI (D.T)
622303
R.TAMILSELVAM BOILER TECHNICIAN