Post Job Free

Resume

Sign in

Electrical Engineer

Location:
Chennai, Tamil Nadu, India
Posted:
July 13, 2022

Contact this candidate

Resume:

RESUME

S.SARAVANAN. BE EEE

Operation and Maintenance with 10 Year’s Experiences for Industrial Commercial Building and “C” Licenses Holder

Mobile No: +91-852*******, Email ID: adrpxw@r.postjobfree.com, Permanent Address:

No.43 North Street, Kottai Patti,

Srivilliputtur, Virudhunagar (Dt),

Pin code:626125

Tamil Nadu

Present Address:

House 7/100 Mahatma Gandhi street

Dhanalakshmi Nagar,Moulivakkam

(Bai kadai) Porur, Chennai-600089

TamilNadu

Personal Data:

Father's Name : R.Subbiah

Date of Birth : 07.06.1988

Sex : Male

Nationality : Indian

Marital Status : Married

Passport No : R3074011

Expiry Date :17.08.2027

Languages :Tamil,English,Malayalam,

Hindhi

Achievement:

Bast performance of DG

Operation Award Year 2011

Best perfoemnnce of Utility

operation Award year 2013

Zero NC maintained of Power

Plant Award year 2018

Salary Details:

Expected Salary: Negotiable

Career Objective:

To achieve a better position in Planning and Scheduling. To provide the expertise in planning and scheduling to the company to achieve the optimum utilization of available resources, with minimum down time. Current Employed:

Compass India Support Services Pvt Ltd- Chennai

Role:Sr.Facilty Engineer from May-2021 to till date Site: Flipkart Grocery Services Pvt Limited, Chennai Academic Details:

Bachelor of Technology Electrical Engineering(BEEE):2010 Tamilnadu State Anna University, First class 89%

Diploma in Electrical and Electronics Engg (DEEE):2007 N.A.M.Polytechnic College, Rajapalayam, First class 88% Summary of Experience:

CIEL HR Services Pvt Ltd - Chennai

Role:Sr.Facilty Engineer from Oct- 2018-April-2021 Site: IBM India Pvt Ltd (Block 10) DLF IT SEZ Park, Chennai

Hofincons InfoTech & Industrial Services- Chennai Role:Shift Plant Engineer (Energy Center)from Aug-2015 - Oct-2018 Site: DLF Building India Ltd,IT SEZ, Chennai.

Shabari Telecable Network Pvt Ltd, Chennai

Role: Sub station & Building Supervisor from June-2010 to June-2015 Site: CTS Sipcot IT Park,Siruseri, Chennai

Software skills:

Languages: Basic C, MS-Office, MS-Excel, Auto-Cad Electrical Certification:

Certificate Holder” by Government of TNEB Tamilnadu Electrical C Licensing (C. No: 47329)

Present Company:

Company :-Compass India Support Services Pvt Ltd

Role & Responsibility: Sr. Facility Engineer from May 2021 to Till Now Facility Maintenance – Daily facility rounds and identifies the issues and promptly makes sure A/c, Electricity, and UPS are functioning smoothly and carry out maintenance activities on regular basis. Operation and preventive Maintenance is my strength, focus on minimizing maintenance costs and optimizing plant availability, with the emphasis on safety

House Keeping – Regular facility rounds to identify issues in Housekeeping/security and Cafeteria etc. and initiate immediate rectification actions, going through the previous days log Register. Ensure proper upkeep and maintenance of entire premises and schedule preparation for housekeeping team. Vendor Management – Identify various contractors, vendors, suppliers for the required goods and services and evaluate the factors such as price, quality, verify and review of AMC, Agreements make sure avail their service at any point of time. Contract letter and evaluate their services periodically and Obtain quote, negotiate the final pricing & release PO with Implementation of well-defined Procurement Standards and check the quality

Asset Management – Maintaining inventory for all movement of assets and to carried out asset verification on every quarter and approve the Gate Pass for all Returnable and Non-Returnable materials and providing asset numbering.

Electrical Safety (knowledge of various aspects of safety and its application)t

Requirement, Familiar with various safe equipments’ and tools

Lockout, Tag out of the electrical switch gears during work as per the India standard

Issue of work permit line clearance to work on electrical distribution network

Aware of electrical safety standards

Requirement and proper usage of protective equipments

Incident and accident reporting

Suggestion and remedial action

Company :-CIEL HR Services Pvt Ltd - Chennai

Site :-IBM India Pvt Ltd,Prince Info-city II,Chennai Role :-Sr. Facility Engineer from Oct- 2018-till now Responsibility Site Operations:

Report to facilities Manager and Client building manager in the event of any major /minor breakdown which would adversely impact business operations.

Capable in handling for Technical, Housekeeping,cafeteria and vendor management

Closely work with the service provider to ensure the agreed contractual terms have been adhered to.

Studying of Electrical Drawings for SLA

Preparation BOQ and get for Qoute from vendor,Estimation and Verification of quantities with BOQ

Close monitoring of safety and security systems for fire alarm and PA System

Provide technical support in installation of Plant machinery on infrastructure part.

Lead and drive infrastructure upgrade related projects short term and long time

Identify areas of energy-saving/efficiency and implement site

Spare part’s Planning for all critical Machinery and stock maintaing in store

Monitor electrical energy, water consumption and power generation on daily basis.

Closely work with the plant management team on the facilities front.

Understand the Facilities Management scope for the facility assigned and develop specific processes and procedures in consultation with FM and ensure implementation and compliance of the processes.

Support in the implementation of short and long-term projects

Ensure factory, PCB, CEIG related Statutory compliances and do necessary followups.

Interface between the service provider and the plant management team.

Licences with the government agencies on PCB/Electrical fronts.

Follow Critical Environment processes & EHS policies laid down by the team

Cafeteria audits and Food quality audits as per standards

Support in technical audits for all installations at periodic intervals.

Processing of vendor Invoices after checking.

Participate in emergency evacuation procedures including crisis management and business continuity. Equipments:-

3*200 KVA UPS System with Amaraja 200 AH Battery Bank

2*40 KVA UPS System with Amaraja 65 AH Battery Bank

2*20 KVA UPS System with Roket 40 AH Battery Bank

15*7.8 TR PAC System and VESDA & ELD

4*5.5 TR Ductable AC

30* Various TR VRF AC Units

Fire alarm PA systems, Sprinklers, Hydrants,

Kitchen Equipments (Cold Freezer,Hot Display Unit,Baimary,Geyser)

LV Panel and related equipments(ACB,contractors,starter,relays) Company :-Hofincons Info-tech & Industrial Services- Chennai Site :-DLF Building India Ltd SEZ, Chennai (Energy Center) Role :-Shift Engineer from Aug-2015 – Oct-2018

Responsibility Site Operations:

To Provide comprehensive management of services covering all facility services to the client with the focus of continuous improvement and administrative support to FM for site teams

Ensure standard operating procedures, work permits are followed by the service provider and adheres to the defined response times

Knowledge in Operation and Maintenance of all Electrical Equipments like in HT/LT distribution systems, Transformer, DG,Electrical panels,Emergency generators, UPS, Air compressors, water treatment plants, Fire hydrant, Sprinkler systems and HVAC system.

Coordinate with vendor staff and staff on-site to ensure smooth operations on site.Ensure zero down time of utilities, Electrical distribution system to ensure smooth production operations.

Responsible for carrying out all maintenance related schedules and shutdowns in consultation with Clients / OEMs

Maintain drawings and documentation for all existing and new components of the mechanical / plumbing and electrical systems.

Daily Conducted the Tool box training and put the work permit after that will allocate the work to team (Electrician,AC technician,Plumber,Welder, DG Operators )

Monitoring the Electrical /Mechnical equipment working condtion and update the reading as per the time line ans cross check the reading as per the OME standarded

Handling of electrical load as per the requirement, Demand calculations and reporting at daily, weekly and monthly basis

Allocate the DG check (A- Check-,B- Check-,C-Check) diesel and oil consumption.

Knowledge of Safety activities include ISO operation and maintenance, LOTO and safety documents, Padlock system

Knowledge of plant Shut down activity and maintenance of electrical, mechanical machinery all break downs are attended without delay.

Awareness on hazardous area classifications and selection of electrical equipment

Maintaining &a monitoring water quantity for cooling towers, domestic drinking, and general-purpose water. Co-ordination for power distribution and control circuits for VFD, Chillers. Equipments:-

5*11KV/415V,2500KVA indoor transformer and OFF load tap change

Indoor 18*VCB 11KV/415V,850A, ABB Make

Various rating ACB of 800A to 5000A make for Schneider

DG 18*2000KVA/11KV Engine Cummins and Alternator Stamford

Heat exchanger cooling type and Cooling tower

10*1100TR water cooled chillers centrifugal type compressor

50 to 100 HP Pumps primary /secondary /condenser Pump’s and Motor’s

Battery and charger, UPS

Building activities which includes Lightning, Elevators, MS controls, Lightning Arrestor

AHU, VAV, Indoor/Outdoor System

Fire alarm PA systems, Sprinklers, Hydrants

Scrubber maintenance in polision control for DG

3*300 KL WTP

Company :- Shabari Tele communication Net work Pvt Ltd Site :- Cognizant Technology Solution, Chennai

Role :- SUB Station/Building Supervisor from June-2010 to June-2015 Responsibility Site Operations:

Handling and Operation and Maintenance of Electrical system in 33KV/433v substation

Monitoring closely the preventive & Predictive maintenance activities of all the critical and non critical equipments along with the service provider and as per the SOP.

Monitoring the Sub station critical Equipments like (Transformer,DG,UPS, HT/LT Panel ).

Instructed the DG operators to be checked the DG working condtion as per the A check list.

Instructed the electricion for monitoring the Load condtion HT panel /LT Panel and check the Panel board condtion as per the check list .If any found abnormal informe to top management.

Daily basis Switch on the Chiller as per the operation requirments daily baiss,before that check the all parameters like (Chiller,Primary/Secondary condenser Pumps cooling tower,water level).

The allocate the work daily basis for building /Equipments snge points and any maintance activity.

Alternate dates will loaded the transformer and reducer the continious running and PPM activity.

Calculate the Power consumption at builiding wise and domastic water also in daily basis.

Support in technical audits for all installations at periodic intervals.

Critical room tempetature monitoring and update the check list.

Ensure standard operating procedures, work permits are followed by the service provider and adheres to the defined response times.

Daily check the opeartion condtion for AHU and VAV, Indoor/Outdoor System.

Maintains clean, safe work area in compliance corporate/OSHA standards maintaining the 5S’s at work place.

Equipments:-

Transformer 4*2500KVA,2*2000KVA 33 KV/433 V indoor type make for kirloskar

DG 6*2000KVA/415V Engine Cummins and alternator Stamford

MD5500 KVA, at .99 power factor commercial load

3*674 TR water cooled chiller centrifugal type compressor

6*375 TR Air cooled chiller screw type compressor, AHU, CHU, VAHU

45KVA, UPS and Battery bank

350KVAR APFCR Capacitor bank

46/50V DC SMPS 6000AH

630A VCB,630A SF6,3000A Micro controlled based ACB

12V DC, 64AH DC battery charger kit maintenance

Fire Alarm PA systems, Sprinklers, Hydrants,

1 HP to 180 HP 3PHmotor

120 KVA,300 KVA UPS Emerson system

4*900 KVAR,2*750 KVAR,APFC capacitor bank

AMF Panel,UDB,PDB,LDB,ELDB

2*35 KL HSD yard auto filling and stopping system

HT/MV/LV Panel and related equipments(contractors,starter,Acb relays) Declaration:-

I consider myself familiar with Electrical Engineering, Electrical safety and management Aspects. I am also confident of my ability to work in a team. I hereby declare that the information furnished above is true to the best of my knowledge.

Place: Chennai YoursSincerely,

Date: (S.SARAVANAN)



Contact this candidate