RESUME

Boiler Operator ( *st & *nd class License )

BALAJI.V

NO.107 /- 1st Pillayarkoilstreet, Lakshmipuram

Chromepet, Chennai.

Mob +91-908*******

D.O.B : 26 - 05 - 1985

mail : adrctq@r.postjobfree.com

Objective

To obtain a career challenge, Where my experience and capabilities Will enable me to bring the best outputs which will beneficial for the belonged Organization as well as my future.

Work Experience

Post Held: ITI Boiler operator

Period: 2007 Jan to 2009 June

Name of the Organisation: Augustan Textile Colours Limited

Kanjikode,Palakkad.

Employee Profile:

Pretaining to troubleshooting preventive and breakdown maintenance of boiler and relative equipments, perform cost-cutting modifications that improve safety

and boost mechine productivity.

Operated and maintained System

Boilers

8 TPH (2Nos), Horizondel Packaged, 3-Pass Smoketube boiler

Working pressure 10.5Kg/cm2 and Heating surface area 190 square metres

Make : Sterling strips Ltd, Mumbai.

42 TPH two-drum water tubes boiler, 25kg/cm2 Working pressure, heating surface area 1511 sq.meters Make : Chittar Vessels Ltd, Trichy.

Valves

Manually operated,Globevalve, Gatevalve, Pressure control valvesBlowdownvalve,Safetyvalve,Butterflyvalve

Air blowers

Singlestage centrifugal blowers

Lub system

Grease lube, Oil lube

Leak arrested system

Veriable sizes metallic glandropes, metallic gaskets, conewashers

Pumps

Horizontal multistage, Centrifugal pumps,Condensate recovery system

Gear pump

Controls

Electric, electronic controls, Manuel controls, Float regulator

Water treatment plant

Multigrade filter, Carbon filter, Resin filter

Heaters

Furnace oil Electric pre-heater, Steam coil pre-heater

Storage Tanks

Furnace oil storage tanks 2 No's, Capacity of tanks each 25000 LTS, Feed water storage tank capacity of 20 kilo liters ( 2No's )

Post Held: Boiler operator

Period: 2010 Aug to 2012 Sep

Organisation: Diamond Food Products,

Perumbavoor, kerala.

Water wall with Steam drum, Fludeised bed combustion boiler Capacity is 16 TPH/hr, Heating Surface Area is 730 sq.meters, and pressure is 35 kg/sq.cm

Make : Industrial Boilers Ltd,

Vapi, Gujarat.

Water :

it's using de- mineralized water and deaerator

Blow down :

Continuous blow down, intermediate blow down

Heat recovery :

Economiser, Air-preheater, Condensate return

Blowers :

Forced draft, induced draft, Primary air draft

Fuel :

husk and coal

Ash handling system :

Mechanical dust collectors, multi cyclone ash collectors and ash silo

Post held : Technical asst ( Boiler Operater )

Department : Engineering department

Period:2012 Sep to 2013 Dec

Organisation : kuwait flourmills & bakery Co S.A.K.

safat-13007,kuwait

Horizantal packaged 3-Pass multi smoke tube boilers.

purpose of steam 'Daily food kuboos products, wheat processing,biscuit bakery products, food Oil refines,cattle feed ect

Make :VKK - STANDARDKESSEL KOTHEN GmbH-Germany

Capacity : 15000 kg/hr ( 2 No's )

Pressure:14 bar

Volume:28.3 m3

Burner type : Pressure jet

Make : Max Weishaupt GmbH,schwandi, Germany

Oil spply : 160 - 1012 kg/hr

Pressure : 100 - 4000 mbar

Feedpump :

Make : KSB - Aktiengesellschaft, D - 67227 Frankenthal

Vertical multistage centrifugal pump, Q : 20.40 m3/hr

Make: SKG-STANDARDKESSEL DUISBURG-Germany

Capacity:10000KG/hr ( 2 no's ) Pressure:12 bar

Burer Type : Rotarycup burner

Make : Saacke bremen Germany

Oilpressure : 3 bar

Oilsupply : 64 - 645 kg/hr

Burner oilspray motor : 3500 rpm F.D. Fan : 2800 m3/hr

Feedpump :

Make : KSB Aktienkesselschaft Germany

Horizondal multistage centrifugal pump Q : 13 m3/hr

Capacity:1600KG/hr( 1 no )

Make : ASK - S.A.R.L. FANAR-LEBNON Operating Pressure : 10 bar TestingPressure :15 bar Heating surface area :40m2

Burner type : Pressure jet

Make : Weishaupt monarch

Oil supply : 15 - 100 kg/hr Vertical Grundfos multi stage feedpump 1 No

Control systems :

Programable logic control

Magnatic float regulating,Thermostatic sensor control

Capacity of Feedtanks : 42000 lits, 12000 lits

Capacity of Dieseltank :

30000 lits ( 6 No's )

COOLING TOWERS SYSTEM :

Oilrefinery purpose coolingwater supply using coolingtowers,condensers using steam create vacume and another one is seawater pumps heat exchangers reduced softwater temp below 20c.

Accessories :

softwater singlestage pumps,coolingwatertank,return water tank Water Treatment :

Sand filter

Carbon filter

Resin filter (COMPOSITE with PE inner shell)

output quantity of water 1000 m3

maintaining ph,tds,hardness.

Post held : Boiler operator

Department : Engineering Department

Organization : Oman National Engineering Investment Company

Site : Ministry Of Health, Al-Sur

Period : 2014 Oct to 2017 April

Horizontal multi tubuler, diesel firing smoke tube boilers, Purposes of hot water, laundry purpose, kitchen use and sterilizing medical equipments

Make : Donnelly, U.K

Boilers Capacity : 6040 lbs/hr (2no's)

Type : Horizontal Multi Smoke Tubes

Pressure : 150 psi

Maintaining of boiler :

Check water level in the boiler

Check the water level in feedwater tank

Blowdown boiler water

Blowthrough gauge glass

Check mobery low water safety cut out for working

Check high pressure cut out for workings

Keep the feedpump in auto

Check blowdown water,feed water for pH and Hardness throw lab

Abserve for any steam leake and rectify

All water tank level and pumps condition

Record above reading in the boiler logbook

Check level of furnace oil main storage tanks and daily usage tank

Incase of initial firing airvent valve open at upto 1kg/cm2 pressure of steam

Post held : Boiler Operater

Department : Engineering department

Period : 2017 may to till

Organisation : Par formulation Ltd, Chennai.( UNIWAY ENGINEERS PVT LTD)

Horizontal multi fire tubes boilers

Make : Thermax ltd, Pune,

Capacity - 8000 kg/hr,

Pressure - 10.5 kg/sq.cm,

Daily report maintaining is a boiler control panel operation and maintaining parameters of pressure, steam flow, water flow, fluegas temparature etc

Quality maintaining of feed water, Softner water, Blow down water, flue gas temperature, Steam pressure and related parameters.

Water plant : sand filter, Carbon filter, Resin filter, Regeneration of resin filter is using sodium chloride,

Fuel Diesel tank capacity is 1000 lits ( 2 No's )

Pumps: Vertical multi stage feed water pumps, Diesel gear pumps, Condensate water return pump, hot water circulation pump, hot water high-level return pumps

Filters : Diesel Primary filters, and valve stainers, Feed water stainers

Valves : globe valve, pressure reducing valve, gate valve and steam condensate traps