Post Job Free
Sign in

Construction Manager Safety

Location:
Richmond, TX, 77469
Salary:
Open for discussion
Posted:
April 25, 2022

Contact this candidate

Resume:

Daniel Rodriguez

**** ** **** **. *******, Texas 77488

****************@*****.***

979-***-****

Objective:

To obtain and sustain a stable career in the Industrial electrical field where I can help Increase productivity, safely and be a part of an excellent team environment. Leading (27yrs) of field Safety and Electrical Management, my goal is to embed the culture of safety through commitment, behavior, awareness, adaptability, information, and justness. Summary:

I have 27 yrs. of experience in the safety and I/E industrial field for leading companies including Bechtel, Tepco management, Nassau Engineering, HB Zachary, Austin Industrial, Lesar Electric, Amber Electric, MMR, & Meitec. I have hands-on experience in the following: Installation of electrical equipment, transformers, switchgear, stress cone, UPS system, lighting & instrument panels, conduit & cable tray, instrument devices, reading electrical documents, blueprints, schematics, wiring diagrams and loop sheets. Point to point troubleshooting, LO/TO, JLG, fork & scissor lift trained. I am also bilingual in English & Spanish. Certifications:

• Valid TWIC Card Holder and can work in a maritime setting (renewal pending)

• NCCER Safety Certification (152992)

• OSHA 10

• First Aid CPR, AED Certified Instructor (renewal pending)

• NCCER Industrial Electrician Certified (152992)

• Electrician Apprentice License 279069

• Computer skills: Word, Excel, Power Point, & Outlook Field work Experience:

1-18- 7-21 (Bechtel) I/E General Foreman Corpus Christi, TX. • Conduct daily safety meetings and audits

• Supervise and plan all lighting, receptacles, instrumentation, and conduit installations, along with panels and junction boxes associated with these devices.

• Daily production time and reports, weekly life critical and unit safety walk down assessments.

• Interfaces with safety and general craft supervisors to work safely and be productive.

•Meet with upper management daily for general field work updates, safety expectations and support. •Order material and electrical equipment to be used and installed in the field 9/17- 1-18 (LA Nesco) I/E Superintendent Covestro Baytown, TX •Attended daily construction meetings and directed craft on assignments and installations of electrical equipment per the NEC and client drawings.

•Maintained detailed documentation through e-mails for client and internal use

• Installed a new (1000A) 24-VDC (UPS) system with (5) new 24VDC electrical distribution panels with the associated junction boxes, raceways, cables.

• Installation also included a 1000A -24 VDC battery charger/Rectifier,24 VDC battery fused disconnect switch, 24VDC battery rack, temperature sensor and a 24VDC main distribution board.

•Associated (incinerator) installation included, demolishing the existing Makolon Incinerator, associated fuel skid and burner management system.

•Replaced existing incinerator, fuel skid, junction boxes and cables and moved the burner management system to DCS/SIS. •Installed a new HIMA-SIS system and reworked motor controls for motors associated with the waste gas system which included new and existing cables to PT’s, TT’S, LT’S, PDT’s, and burner devices. 11/16-6/17 (Bechtel) I/E Foreman Exxon Baytown, TX • Installed & terminated temporary lighting for general crafts

• Terminated all welding six packs and ecard power sources throughout unit

• Installed & terminated receptacles in connexs and office trailers throughout the facility.

• Supervised Installation of power & instrument conduit, basket tray, lighting panels & inst. devices. • Witnessed loop checks, commissioning, and startup.

•9/16 -1/17 - (TGE Industrial) E/I General Foreman JX Nippon, La Porte, TX. •Walked down new and existing job packages with client

• Supervised all I/E installations, transformers’, j-boxes, conduit, general instrument transmitters etc. •Responsible for employee time and purchasing material for general job scopes.

•Red-lined drawings, kept meg sheets, grounding and bonding records for each job scope

•Walked down each job completed with client before commissioning and start-up 10/14 – 9/16 (TEPCO LLC) – E/I- QA/QC –& Safety Coordinator

•Responsibilities include in the safety department, overseeing the Safety construction aspects of the project. Overseeing the implementation of corporate health and safety procedures, and client site specifics. Conducted daily, weekly, and monthly reports of field observations and job tasks by personnel development of hazard analysis for all work activities on site. Facilitated daily, weekly, and monthly safety meetings. Lead for accident/incident investigation. HSE Manager Site tracking. Developed weekly corporate communication Safety topics & assisted other safety personnel for the new and existing projects, which included sub-contractors and plant maintenance. I also tracked weekly walk-through observations and led accident/incident investigation.

•Worked with client to set up all document controls plans for the DCS modernization project from Fisher Provox system to Honeywell Experion PKS. Also set up instrument & electrical test plans, hold points and instrument cut- over procedures. • Interface with the client project manager and key personnel on a regular basis for project updates and strategies. • Performed field inspections on all received equipment for Honeywell Experion DCS system cabinets and field mounted control panels, remote panels, distribution panels and general raceways.

• Coordinated and planned with contractors, operations, maintenance, and field coordinators for an organized, controlled, and successful startup and turnover.

• Built power, fiber, and grounding system packages. Along with all I/E loop folders. 6/14-10/14 (3-J Ryan) – I/E Supervisor & Safety Technician Kuraray, La Porte, TX. • Safety orientated all on boarding employees for general work in the Invista facility & coordinated weekly safety audit. • Responsible for overseeing all phases of I/E installations of new Honeywell DCS and Triconex cut-over upgrades. I planned and worked side by side with the client to identify any discrepancies on loop sheet drawings before construction. Ensuring that I/E installations were done correctly the first time.

• Witnessed I/E loop checks, motor runs, and insulation resistance testing of all power cables etc. Reviewed and approved turn over packages according to project specifications. Spending time in the field attending safety meetings with other I/E supervisors and being involved with craftsmanship during construction ensuring deadlines were met in a productive and safe manner finishing projects ahead of schedule. I was also responsible for doing timesheets and purchasing material for other ongoing projects. 11/13 - 6/14 (Nassau Engineering) I/E - Supervisor JX Nippon, La Porte, TX. • Responsibilities Include: Blueprint, Schematics, & wire diagram reading for electrical job scope equipment installation of transformers and switchgear.

• Installation of power & instrument conduit, cable tray, lighting panels, duct bank, and instrument transmitters. Held daily safety and production meetings for existing and new industrial construction and refinery turnaround completions. • Planned and managed several ongoing projects and purchased material.

• Witnessed loop checks, commissioning, and startup. 03/13 – 11/13 (MMR Group) Journeyman Electrician/Safety Coordinator Oneok, Mont Beliveau, TX. • . As a safety coordinator I worked with a safety team forming a strong sustainable safety culture thereby improving awareness and work ethics in the industrial construction field. This included working with the company site safety program team which ensured education knowledge of program intent and the guidelines implemented, monitored, and revised as necessary. I provided active leadership to ensure corporate policy; regional electrical practices and procedures were followed in projects. I also coordinated regular safety audits and meetings.

• On the electrical side, I mounted j-boxes, installed conduit, & cable tray. Phoned and did a continuity check on wires & cables for verification and terminated lighting and instrument panels. Work History – Continued

2004-2006: Amber Electric, Austin Industrial

2002-2004: HB Zachary, MMR

1996-2002: MMR

Reference:

Greg Felicien 281-***-**** – I/E Construction Manager - CAP

Noe Maldonado 832-***-**** - Electrical Superintendent - Enpace

Jesus Cisneros 713-***-**** – Safety Manager - Houston Controls



Contact this candidate