Post Job Free

Resume

Sign in

Electrical Engineer Aramco

Location:
Al Malaz, Riyadh, Saudi Arabia
Posted:
April 07, 2022

Contact this candidate

Resume:

MUHAMMAD IRFAN YASIN

MUHAMMAD IRFAN YASIN

Electrical Engineer

Bachelors in Technology (B. Tech)

University of Engineering & Technology Lahore

Associate Engineering (D.A.E)

EXPERIENCE: 16 years

Mobile No: +966-********* Email adds: adqpnt@r.postjobfree.com PROFILE SUMMARY:

I want to be part of a dynamic and progressive organization, which offers challenging working environment where one can utilize energies and competences in a positive direction and contributes towards overall objectives of organization. On hand working experience in construction industry specialized in review shop drawings, specification, standards, material submittal report, HVAC, Infrastructural work, Medium Voltage, Low Voltage, Low Current, Trenching, Duct Bank, Cable ladder, Cable Tray. Megger Testing, Earth Resistance Testing, Short Circuit and Continuity Test. Fruitful and well known experience of Residential and Commercial Projects with Infrastructure Work at site along with, Multi Dimensional Experience in different Organizations. DETAILED WORK EXPERIENCE:

Employer: POYRY (Switzerland)

Project Shuqaiq Ph3 Water Transmission Systems

Value: 3,080,907,766.83 (S.R)

Position Electrical Engineer

Client SWCC (Saline Water Conversion Corporation.) Duration December 2018 to January 2022

Project Shuqaiq Ph3 Water Transmission Systems

Employer: Jacobs Zate (Jacobs, Zamel & Turbag ) Consulting Company Project Yanbu2P&WProject

Position Electrical Engineer

Client MARAFIQ

Duration September 2015 to November 2018

Employer: Sinopec International Petroleum Service Corporation Project Yanbu Medina Phase 3 Water Transmission System Project Position Electrical Engineer

Client SWCC

Duration September 2012 to August 2015

Employer: Mansur Al Mussad Jeddah

Project King Abdullah Sports complex

Position Electrical Engineer/Electrical Q.C.

Client Saudi Aramco

Duration December 2009 to July 2012

Employer: Micronet / Nayatel group of companies

Project Implementation of fiber and copper network by using DSLAM & OLT Position Site Engineer

Client Pakistan Telecom Company

Duration August 2005 to November 2009

MUHAMMAD IRFAN YASIN

Responsibilities:

Review design drawings and project specifications.

Site surveillance, quality assurance for Low voltage, low current, HVAC & Earthing System.

Inspection of lighting, power, low current, Earthing and HVAC activities.

Issue site work instructions, Non Conformance reports, review change orders, variations orders, daily, weekly and monthly progress reports and invoices against work completion.

Testing and Commissioning of Electrical and HVAC system.

Review As built drawings.

Responsible for maintaining project site electronic documentation and archiving.

Review & Follow up project completion schedule and expedite site work.

Coordinating with the other departments, clients and contractors Designing and conducting tests on the products.

Installation of all type of hospital and bank equipment power and lighting distribution panels, battery bank charger, UPS for telephone, data, CCTV, Fire Alarm, etc.

Maintain records of material tests performed and executed works.

Prepare daily progress report to the RE. This includes works order, material delivery, and daily inspection.

Supervision of main electrical room's installation of MDBs, EMDBs, ATSs, Switch Gear & Generator with Megger Testing and termination.

All main electrical room work finalized for bus bar fitting, Trenching, duct bank installation, cable laying from transformer to MDP (Main distribution panel).

Including equipment with transformer as ACB (Air circuit breaker)VCB(Vaccum Circuit breakers), MCCB (moulded case circuit breaker), MCC (motor control center)for irrigation pump with irrigation control system, non potable water pumps, potable water pumps, fire pump with jockey pumps (Control from EMDP & ATS).

Finalize work for installation of generator and complete four hours load test with MDP & EMDP as per specifications testing and commissioning.

Finalize work for the laying of power and telecommunication cable in trench, direct buried cable and megger test in the duct bank UPVC conduits.

Arrangement with the suitable fitting with snap lock end bell for all size of conduits and cables. Safety warning tape for cable conduit & direct buried cable.

Finalize work for grounding network and lightning protection and earth testing and test report.

Installation of Cable trays, trunking and cable pulling and in compliance with requirements of Project.

Experienced in site supervision works for LV networks including electrical Substations.

Responsible for Installation, Testing & Commissioning, servicing and maintenance of all electrical equipment's.

Ensuring that material is properly delivered at site and received by Store at Site.

MV/LV cables, MV substations, distribution transformers 33 13.8KV, MVSG, RMU, standby diesel Genset, MCC, MDB, VFD, LV panels, fire alarm, cable ladders & trays, AC motors & pumps, instrumentation. JOB RESPONSIBILITIES IN LOW CURRENT SYSTEM:

DATA & TELEPHONE SYSTEM

Supervision for cable lying in trench, direct buried and in cable tray.

Installation of all type of telephone equipment such as TTB (Telephone Terminal Board) MDF (Main Distribution Frame) punching continuity test of 24 AWG, 22AWG, 20AWG 2 pair to 200pairs.

Splicing of Fiber Optical Cable. Pulling and termination of CAT6 and CAT6A. FIREALARM SYSTEM:

Supervision for fire alarm cable lying as per drawing.

Networking between FACP TO FACP & FACP to building device such as smoke detectors, heat detectors, gas detectors, break glasses, manual station, pull stations, interface units, sounder bells and beam Detectors.

Maintenance and testing of FM200.

SECURITY SYSTEM:

Supervision for fire alarm cable laying for networking of all reader interface module and door devices. Such as metal detector, card reader, key pad reader, electromagnetic door lock, electro magnate door strike, electromagnetic door MUHAMMAD IRFAN YASIN

contact, exit push button, sounder bell etc.

BUILDING MANAGEMENT SYSTEM:

Supervision for BMS (building management system) networking bus lying from DDC (Digital control center) to DDC. SCADA Panel DDC to all type of lighting control, pump room accessory control, and cooling unit's control, boiler control etc. CCTV AND MATV SYSTEM:

Supervision for all type of fixed, dome cameras, IP camera, outdoor and indoor camera's with illuminator infrared, multiplexer switches and video recorder for MATV installation of all types’ splitters, amplifiers and channel units. EDUCATION:

Bachelors in Technology (B. Tech)

University of Engineering & Technology Lahore (Major: Elect &Telecom)

Diploma in Associate Engineering (D.A.E)

Punjab Board of Technical Education Lahore

Secondary School Certificate (S.S.C)

Federal Board of Secondary Education (Group: Science) COMPUTER /TECHNICAL SKILLS

Good Communication Skills.

Efficient with All version of Windows

MS OFFICE All versions

Office Automation

Computer Hardware troubleshooting and management.

Electrical installation (low current, low voltage and medium voltage)

Electrical designing, Design Review, load calculation, load scheduling.

Technical Specifications & BOQ, Site Coordination. PERSONAL INFORMATION:

Name Muhammad Irfan Yasin Khan

Date of Birth 26th January 1982

Marital Status Married

Religion Islam

Nationality Pakistani

Iqama Status Transferable

Driving License Saudi Arabia Valid Driving License

Language Known English, Arabic, Urdu

STRENGTH

Easily learn and adopt the new technology.

Having good communication skill.

Innovative, co operative and highly self motivated.

Team player with excellent camaraderie.

Familiar with international HSE standards.

I certify that above mentioned information’s are true and fact as per my belief and knowledge. Muhammad Irfan Yasin

Electrical Engineer.

.



Contact this candidate