Post Job Free
Sign in

Sec School Wind Farm

Location:
Chandigarh, Chandigarh capital, India
Posted:
November 29, 2021

Contact this candidate

Resume:

Profile

Perform scheduled maintenance and preventative repairs on all electrical systems, equipment, and machinery.

Knowledge in Snag list, CMMS, work permit system, confined space and various types of works and shut down activities..Knowledge in LOTO. • Developed skills in international and multicultural work environment.

• Knowledge learned through HSSE, HSEQ,, HSE and CAPA .Worked in 5s and six sigma. Knowledge gained to work with sophisticated and Nondestructive electrical measuring and testing instruments.

CONTACT :+919*********

ADDRESS

10A,Ramar Madam North Street,

Velipalayam,Nagapattinam

Pin ;611001

EMAIL:

**********@*****.***

SKILLS

ELECTRICAL HT/LT,

TRANSFORMER, 132/6.6KV,11KV/415V,6.6KV/415V

SUBSTATION

POWER PANEL CONTIGENCY&SHUTDOWN SWITCHGEAR SERVICE,

BATTERY,GENERATOR,

UPS O&M ACTIVITIES, CCTV maint, MOTOR CONTROLS,

HVAC MAINT,

Quality Management

KNOWLEDGE IN SOLAR,

DOCUMENT MANAGEMENT

BUILDING ASSET MANAGEMENT,

SUB CONTRACTOR MANAGEMENT,

WORKORDER MANAGEMENT,

SAFETY.

EDUCATION

VALIVALAM DESIKAR POLYTECHNIC

AUG 1993–APRIL1997

DIPLOMA IN ELECTRICAL AND ELECTRONICS ENGINEERING (DEEE) 78.5%

V.S BOYS HIGHER SEC SCHOOL

June 1992 –APRIL1993

SSLC 82.6%

WORK HISTORY

ELECTRICAL INDIA –NAGAPATTINAM (SITE SUPERVISOR)

APRIL 2018 –TILL DATE

Site Survey,Cable route measurement.Panel erection and maintenance acivities.

Building wiring and lighting installation.

Manpower and material arrangement.

Work order and gate pass arrangement.

Material Quality approval arrangement get from quality department.

Daily and monthly report to the respective individual.

FMM-QATAR (TECHNICAL OFFICER )

JUNE 2013-March 2018 - Hammed international airport-Qatar

Airport hotel and lounge Maintenanace,l maint of MDB,SMDB,DB and UPS Panel maint,workorder followup, Asset and Document Management and assist the manpower to 11KV/415V,6.6KV/415Vcontigency activity and indoor substation shutdown maint &Switch gear Service activities of LVSS,ELVSS AND ATS .

Co-ordination with Mechanical department for HVAC Chiller,Cooling Tower,AHU Maintenance activities.

co-operation with sub-contractors.

Knowledge in first aid and firefighting

Appreciations for intelligent &hard work.

Reason for leaving:For Personel reason to take care of my Family…

SHRI VAARI ELECTRICALS PVT LTD (CHENNAI) (SITE INCHARGE ) FEB 2013-MAY 2013

Ensure the Team below him is well performing the job assigned with safe working procedure. Rectified technical issues and worked for billing issues. Escalated site requirement to management when needed.

Reason for leaving:For better prospects

EMCO ABUDHABI( musanada project) (ELECTRICAL SUPERVISOR )

MAR 2011-APR 2012 Building Electrical, Fire Alarm and CCTV,HVACMaintenance

Developed schedules to complete work within deadlines. Knowledge improved in SLA Concept.Achieved solutions for municipalities Power demand.

Reason for leaving: for better Prospectous &my family reason ..

KREMENCO ( KNPC—SHUAIBA-KUWAIT) (ELECTRICIAN&SHIFT ASSIT)

DEC 2006 –MAY 2009

132/6.6KV 31.5MVA OLTC TXR, 6.6KV/415V 1000KVA NLTC TXR &CONCRETE SUBSTATION SWITCHGEAR MAINTENANCE, ELECTOMECHNICAL, MICROPROCCESOR RELAY PANEL MAINTENANCE, Knowledge in DCS, fire extinguisher and Industrial

Battery maintenance. Achieved best switchgear maintenance practice. Reason for leaving:For better prospects and to live with my family.

BHARATHI TELEVENTERS LTD -TAMILNADU (TECHNICAL OFFICER)

JUNE 2002 TO OCT 2006 ( Chennai,Madurai&Trichy)

Electrical Auditing of power panel, Generator, battery, UPS and fire alarm of RSU&DLC,Achieved Project& Fault clearance on with in SLA. Reason for leaving:For better prospects&to meetout the family needs.

PRIME ITI KILVELUR (JUNIOR TRAINING OFFICER)

FEB 2001 To FEB 2002

Training given asper NCVT Pattern for Electrician trade.Skill development training given under ministry of India.

Reason for leaving: For better prospects &living with my Neighbours

TACKE WIND ENERGY INDIA PVT. LTD,Aralvoimozhi

ELECTICAL SUPERVISOR/OPERATOR:SEP2000 TO JAN 2001

Knowledge in Remote WIND FARM MAINTENANCE 11KV/415V Oil type Txr and earth bit Maintenance. Achieved high wind energy operation.

Reason for leaving: For Personnel reason-Living with my parents.

.

MADURA COATS VAYALLA LTD, MADURAI (ELECTRICAL TRAINEE )

JULY 1998 TO MAY 2000

Industrial electrical maintenance, Electrical motor and starter Maintenance, 11KV/415V switchgear maintenance. Electronic counting machine maintenance. Worked to avoid breakdown and Effort put for high production.

Reason for leaving: Contract abolished.

VASANTH ENERGY CONSULTANTS,UDUMALPET (WIND FARM OPERATOR)NOV 1996 TO NOV 1997

1.5MVA AMTL WIND FARM MAINTENANCE, NLTC TXR MAINT, MONITORING AND CONTROLLING ACTIVITIES DONE. Worked to avoid Reverse power. Reason for leaving: For Personnel Reason instructed to live with my Neighbours .

TOTAL WORK EXPERIENCE : 22 YEARS AND ABOVE.

RAMACHANDRAN VISWANATHAN

Supervisor-Electrical&HVAC

**********@*****.***

,+919*********



Contact this candidate