To work in pragmatic way in an organization, where I can show my talent and enhance my skills to meet company goals and objective with full integrity and zest.
Professional Summary:
•Twelve years of experience in the field of Testing & Commissioning of electrical equipment’s from 415V to 400KV system.
•Testing and commissioning of LT,HT panels, Auxiliary relays,motors CT, PT, CVT, VCB, SF6, ECB, isolater and Power Transformer.
•Expertise in installing, Testing & commissioning of various Electrical equipment’s.
•Knowledge of Transformer Stability & Differential Protection, Motor protection, and studying Control & protection drawings of all electrical system.
•Providing Engineering and Technical support to clients at site.
•Adept at preventive and breakdown maintenance work.
Academic Qualifications:
Sri Sasthainstitute of engineering and technology – CHENNAI
•B.E. in Electrical and Electronic Engineer–2004 to 2007
Meenakshi ammal polytechnic college- UTHIRAMERUR
•Diploma in Electrical and Electronic engineering- 2002 to 2004
Employment Highlights:
Experienced as an electrical testing and commissioning engineer around twelve years
EMPLOYER
•HIVELEM Industry Alandur, CHENNAI
Position: quality testing engineer.
Duration: September 2009 –january2011
CURRENT EMPLOYER
•Voltech Engineers wll, Qatar ( for overseas projects,)
Position : Testing &Sr.Commissioning Engineer
Duration : April- 2011 to Till Date
Nature of work:
Testing & Commissioning:
Switchgears:
•Installation, Testing and commissioning of Electrical Panels ranging from LT panels (415 V) up to HT Panels (11kV & 400kV).
•Erection of HT & LT Motors with various ratings (from 0.24KW to 720KW) and Unit Auxiliary Transformers.
•Testing of various numerical non-directional relays and calculating the respective trip current value.
•Commissioning of various electrical equipment’s such as HT Motors, LT Motors, Transformers and Generators with necessary protection wiring.
Switchyards:
• Testing & Commissioning of various switchyards ranging from 132kV to 400 KV (including checking Analog & Digital signals to BCU & various relays and remote operation through SAS & complete interlock checking).
•Scheme checking of Control & Relay Panels and control wiring to the individual equipment’s such as Breaker, Isolator& Earth switches.
•Erection &Testing of Current transformer, Potential transformer, SF6 Breakers and Isolator.
•Testing of Power transformers up to 200 MVA with complete body protection wiring (Make: Siemens,ABB,BHEL, Bharat Bijlee, Hyosung, Emco, Andrew Yule, Voltamp Transformers etc)
•Local and Remote operation of Breaker, Isolator and Earth switch with respect to all the interlocks.
•Preparation of cable schedule and scheme checking with all interlocks.
Key Responsibilities:
•Understanding the Client requirements and Functionalists.
•Preparing the Erection,SLD, Testing and Commissioning Program & Procedures.
•Finding the root cause of fault in control schemes, equipment’s & Auxiliaries to avoid repeated faults.
•To co-ordinate with electrical contractor for electrification, Execution and Erection work.
•Attending technical discussion with client/consultant representative for doing any modification in design according to system requirement.
•Co-ordination of DCS interfaces with Electrical system.
•Assist in the negotiation of contracts with an optimum mix of price and quality
Project Details:
Overseas projects;
•Currently working as a testing and commissioning engineer in QATAR through M/S.Voltech engineers wll and approved by consultants to do testing and commissioning intheirGIS substations, some notable substations are
AL JAHHANIYA SUBSTATION
•Substation rating : 132/11 KV
•GIS make : SIEMENS,8DN8
AL-SAKHAMA SUPER SUBSTATION
•Substation rating : 400/132/11 KV
•GIS make : SIEMENS,8DQ1
AL DHAKIRA SUBSTATION
•Substation rating : 132/11 KV
•GIS make : SIEMENS,8DN8
AL WUKAIR-1 SUBSTATION
•Substation rating : 132/11 KV
•GIS make : SIEMENS,8DN8
AL-SHAHHANIYAH SUPER SUBSTATION
•Substation rating : 220/132/11 KV
•GIS make : SIEMENS,8DN9
RAS ABU-ABOUD-2 SUBSTATION
•Substation rating : 132 /11 KV
•GIS make : SIEMENS,8DN8
AL-SHAHHANIYAH SOUTH SUBSTATION
•Substation rating : 132/11 KV
•GIS make : SIEMENS, 8DN8
BIN MAHMOUD-2 SUBSTATION
•Substation rating : 132/11 KV
•GIS make : SIEMENS, 8DN8
GIS Projects:
•Worked with all leading GIS manufacturers such as ABB,SIEMENS,Hyosung in Qatar and successfully commissioned their substations as per the schedule drafted.
•Commissioned the relay panels and modified circuits according to the protection schemes and updated it with KAHRAMAA standards.
•Configuration as per schematic diagram & Testing of Protective Relays.
• Testing & commissioning of different Electrical equipment such as Protection Relays Protection in GIS substations.
•Co-ordination with client in As Built Scheme drawing submission. As build cable schedule submission and all site activity to satisfy the customer.
•Stability checking of power transformers, HT motors and testing of master trip relay and auxiliary relays.
Domestic projects:
1. Testing & commissioning of 6.6 KV switchgear for M/s. Tata steel Pvt Ltd IN TATA NAGAR through M/s. L&T pvt Ltd (BMHS).
2. Testing & commissioning of 6.6 KV switchgear for M/s. Tata steel Pvt Ltd IN TATA NAGAR through M/s. L&T pvt Ltd (E & I).
3. Testing & commissioning of 132/33 KV GIS for M/s. Tata steel pvt Ltd IN TATA NAGAR through M/s. Voltech Engineers Pvt Ltd.
4. Testing & Commissioning of 2*250MW Thermal power plant in 400KV switch yard for M/s Damodar valley corporation Pvt Ltd in KODARMA through M/s. BHEL Private Ltd.
5. Testing & commissioning of 33/11 KV Substation for M/s. Orissa electricity board in JAIPUR through M/s. AREVA.
6. Testing & commissioning of 132/33 KV Substation for M/s. sail pvt Ltd in BOKKARO through M/s. SIEMENS Private Ltd.
7. Testing & commissioning of 132/27 KV substation for M/s. west bengal railway board in DANKUNI through M/s.ECI engineering & costruction company Ltd
8. Testing & commissioning of 11KV/415V ATC tower project for M/s. dial in NEW DELHI through M/s. L&T Pvt Ltd(BUILDINGS & FACTORY)
9. Testing & commissioning of 110KV GIS, 33 KV and 27KV CHENNAI METRO STATIONS through Siemens Pvt.Ltd.
Personal Information:
Name : V.M. Suresh babu
Father’s Name : V.S. Manickam
Nationality : Indian.
Date of Birth : 25th/07/ 1984.
Languages Known : Tamil, English, and Hindi.
Permanent Address : 3/988 Bharathinagar,
Athimanjeripet-631202,
Pallipet (T.K),
Thiruvallur (Dist.).
Passport no :L7625842
Date of expiry 17/03/2024
Declaration:
I hereby declare that above mentioned information is correct up to my knowledge and I bear the responsibility for the any correction of the above-mentioned particulars.
Place:
Date: (V.M.SURESH BABU)