Post Job Free

Resume

Sign in

Saudi Aramco Engineer

Location:
Doha, Qatar
Salary:
15000
Posted:
February 13, 2022

Contact this candidate

Resume:

MOHAMED

KHALIFA

E L V E N G I N E E R

MY BACKGROUND

ELV Engineer with 11 yrs experience in

Planning, Designing, Engineering, Installation

& Commissioning of BMS, Access Control

System, Public Address System, Fire Alarm

System, CCTV, IPTV & IPClock for high-rise

buildings (Hospitals, Hotels & Banks). Good

Skills in construction management and

leadership, team building, effective

communication and conflict resolution.

PROFESSIONAL SKILLS

Expert in: Auto CAD 2021, BMS, Access Control

System, Public Address System, Fire Alarm

System, CCTV, Engineering, Installation &

Commissioning

REACH ME AT:

Mobile: +974********

Address: Dammam 32242, Saudi Arabia

Email: adp7tz@r.postjobfree.com

WORK BACKGROUND

*Access Control System, Public Address System, Fire Alarm System, CCTV, IPTV, IPClock System & BMS

* Obtained tender Proposal from client to BMS, Access Control System, Public Address System, Fire Alarm System, CCTV, IPTV & IPClock System

* Liasioned with Contractors and Sub-contractors regarding the proposal and to meet the client's scope of work.

* Designed BMS, Access Control System, Public Address System, Fire Alarm System, CCTV, IPTV & IPClock System field devices in the necessary locations as per MOI recommendation and produced to review of Client's Consultant Team for approval.

* After the design approval, prepared riser to BMS, Access Control System, Public Address System, Fire Alarm System, CCTV, IPTV & IPClock System according to the plan.

* As per the consultant requirements, Planned new device addition (variation order) to BMS, Access Control System, Public Address System, Fire Alarm System, CCTV, IPTV & IPClock System in the missing location for any architectural change.

* Then Generated BOQ (conduits, wires & device Quantity) for client approval as per site requirements for to BMS, Access Control System, Public Address System, Fire Alarm System, CCTV, IPTV & IPClock System.

* Trenching for laying new cable for BMS, Access Control System, Public Address System, Fire Alarm System, CCTV, IPTV & IPClock System.

* Organized materials and manpower to oversee the smooth installation at site.

* Prepared, Scheduled, Co-ordinated, and monitored all site installation works related to BMS, Access Control System, Public Address System, Fire Alarm System, CCTV, IPTV & IPClock System.

* Monitored project progress complied with desgin specifications.

* Directed engineering activities, assigned tasks, provided training and support regarding BMS, Access Control System, Public Address System, Fire Alarm System, CCTV, IPTV & IPClock System field devices Installation.

* Maintained quality control in every phase of installation in terms of scheduling, planning, personal performance and team dynamics.

* Installed Outside and Inside field devices to BMS, Access Control System, Public Address System, Fire Alarm System, CCTV, IPTV & IPClock System as per installation and quality standards.

* Encoding the analog to digital through co-axial to IP adapter inside the data center.

* After installation, tested and commissioned BMS, Access Control System, Public Address System, Fire Alarm System, CCTV, IPTV & IPClock Systemand the electronics integrated with the Database Servers.

*Certainly prepared System Overview, System architecture, Datasheets, Installation Manual, Standard operating Procedure, Equipments Schedule, BMS, Access Control System, Public Address System, Fire Alarm System, CCTV, IPTV & IPClock System - Controller Components, Field devices and Central Software & Hardware Pheripherals.

* Weekly Inspection & Testing for BMS, Access Control System, Public Address System, Fire Alarm System, CCTV, IPTV & IPClock System Browsers were conducted to verify the resolution of image in each cameras.

* Every 3 months datas were exported from BMS, CCTV, Access Control System, Public Address System, Fire Alarm System,IPTV & IPClock System servers for Quality Inspection to check the integrated system & Incident.

* Annual Checking of BMS, CCTV, Access Control System, Public Address System, Fire Alarm System,IPTV & IPClock SystemDatabase Servers & Hard Disk were done to check system comply with Industry Installation Standards.

ELV Engineer

INoora Waqian Al Dossary Est, Dammam, Saudi Arabia Aug 2013 - Present

MOHAMED

KHALIFA

E L V E N G I N E E R

MY BACKGROUND

ELV Engineer with 11 yrs experience in

Planning, Designing, Engineering, Installation

& Commissioning of BMS, Access Control

System, Public Address System, Fire Alarm

System, CCTV, IPTV & IPClock for high-rise

buildings (Hospitals, Hotels & Banks). Good

Skills in construction management and

leadership, team building, effective

communication and conflict resolution.

PROFESSIONAL SKILLS

Expert in: Auto CAD 2021, BMS, Access Control

System, Public Address System, Fire Alarm

System, CCTV, Engineering, Installation &

Commissioning

REACH ME AT:

Mobile: +966*********

Address: Dammam 32242, Saudi Arabia

Email: adp7tz@r.postjobfree.com

WORK BACKGROUND

* Responsible for Saudi Aramco Medical Service Organization's Fire Alarm System Installation, Repair

& Maintainence as per NFPA 72 - Chapter 10.

* Every week, Fire Panel push buttons (Supervisory, Trouble, Acknowledge, Reset & Alarm) checked for normal operating condition.

* Voltage Ratings (24Vdc) measured across the Power Supply Card of Honeywell Fire panel every 2 weeks to avoid voltage drop during Fire Incidents.

* Fire Devices displaced during refurbishment were re-arranged to maintain 20 ft. distance between Fire Detector.

* Smoke Detectors with high dirty level were Observed from the Trouble History of the Fire Panel.

* As a reactive maintainence, Smoke Detectors were disconnected, cleaned & reconnected for proper polling of device with Fire Panel.

* Periodical Check for Notification Appliance Circuit (Sounders & Paging System) were done.

* On Monthly Testing, Smoke, Heat Detectors and Manual pull station were intiated & active address confirmed in BMS.

* Quarterly Inspection done to confirm Fire Detectors were away from Electrical Hazards & AHU Diffusers.

* Half-Yearly Fire Drill conducted to alarm all Sounders connected to the Fire Panel to confirm occupants notified during Fire Incident.

*During Annual Testing & Inspection, fire devices(Smoke, Heat Detectors, Flow Switch and Manual pull station) were intiated and all anxillary output (AHU, Pressure Fan, Exhaust Fan, Fire Dampers, Fire Doors & Elevators) activation were checked along with Notification Appliance Circuit .

* Inspected fire systems and Worked in all project stages from design to commissioning according to Saudi Aramco G.I. standards.

* Developed solutions and formulated the design by collecting data related to operation requirements and process.

* Estimated cost for engineering, labor, equipment and materials based on design & expenditure request.

* Upgraded Fire Alarm System in Saudi Aramco Medical Service Organization.

* Improved economic factors to support proposals for new construction, modifications or maintenance to equipment

Fire Suppression System

* Weekly Inspection & Testing for Fire, Sprinkler & Booster pumps were conducted to calibrate Cut-in

& Cut-off pressure settings.

* Every 3 months Remote Inspector Test Valve for Fire Sprinkler System were activated to check the mechanical Bell Gong response incase of Fire Incident.

* Annual Cleansing for Fire Hose Reel, Hydrants, Fire Water Tanks & Sprinkler System were done. Building Management System

* Obtained Standard Operating Procedure (SOP) to all MEP Equipments to be interlocked with BMS from responsible site Engineers inorder to provide Schematics for ease understanding to Consultant

& Client.

* As per the approved Schematics & SOP from Client/Consultant, request was given to the client to provide CAD drawings for Mechanical, Electrical & Plumbing System .

* After receiving CAD drawings, Seggregated MEP System interlocked withBMS @ each Floor individually inorder to display in the riser.

* As per the seggregation, designed riser with all MEP Equipment connected to each DDC and located DDC inside Mechanical Room (to save wiring cost).

* Certainly prepared IO points referring SOP, Schematics & Riser to each Floor Individually. Project Engineer

IBadr H. Al Hussaini & Sons Co., Dhahran, Saudi Arabia Mar 2011 - Apr 2013

MOHAMED

KHALIFA

E L V E N G I N E E R

MY BACKGROUND

ELV Engineer with 11 yrs experience in

Planning, Designing, Engineering, Installation

& Commissioning of BMS, Access Control

System, Public Address System, Fire Alarm

System, CCTV, IPTV & IPClock for high-rise

buildings (Hospitals, Hotels & Banks). Good

Skills in construction management and

leadership, team building, effective

communication and conflict resolution.

PROFESSIONAL SKILLS

Expert in: Auto CAD 2021, BMS, Access Control

System, Public Address System, Fire Alarm

System, CCTV, Engineering, Installation &

Commissioning

REACH ME AT:

Mobile: +966*********

Address: Dammam 32242, Saudi Arabia

Email: adp7tz@r.postjobfree.com

WORK BACKGROUND

* Trained team of 7 members to operate, maintain, troubleshoot & repair facility components as per manufacturer procedures (Controls/Start-up/Shutdown/Emergency Over-Ride/Seasonal Changeover).

* Executed maintainence plans to maximize equipment operational availability, while minimizing equipment downtime.

* Gave oversight for Energy Process Controls, facility components, system database servers, networking devices and supporting structures, Automation & BuildingManagement/MonitoringSystem(CMMS) to include design, integration, operation and routine/emergency maintenance service.

* Documented PM (Preventive Maintenance) program for entire BMS system to ensure all components are properly operating, inspected, cleaned, tested and calibrated on a routine basis, and that all software is upgraded as needed.

* Made inspections and troubleshooted problems in the event of equipment failure and recommended necessary parts for effective repair.

* Generated and reviewed daily system alarm logs & ensured critical alarms were properly investigated and reported. Analysed periodic system monitoring reviews to ensure all required points are being monitored.

Operation Maintainence & Control Room Engineer

SKYTEL TELECOM PVT. LTD., Tamil Nadu, India

Nov 2008 - Feb 2011

* Conducting Site Audit - Azimuth/ Tilt/ BCCH/ BSIC/ Height. Identifying BCCH/ BSIC Clash. Optimizing BCCH without Co-Channel & Adjacent Channel Interference.

* Performing Short Call/ Long Call, GPRS, Idle Mode Drive Test while analyzing DTX/ TA/ MS Power Control/ Frequency Scanning & Locking/ Forced HO.

* Identification of Call Drop/ type/ Properties/ Identification/ Solution. HO failure/ Reason/ Type & Solution

* Conducted WiMAX Drive test on External Band Interference & Indoor Penetration Loss during Radio Continous Wave Testing (RCWT) for Noise and interference.

* Handled Commissioning and integration of NEO Pasolinck, SDH and PDH, Indoor unit and Outdoor unit, system syncronization and MW equipment system line-up.

* Operated & Maintained both IDU and ODU to Rx level upto 35dBm for 8dBm Tx Level. Telecom Engineer

Al Habib Trading & Cont. Co., Dammam, Saudi Arabia May 2007 - Jul 2008

MOHAMED

KHALIFA

E L V E N G I N E E R

MY BACKGROUND

ELV Engineer with 11 yrs experience in

Planning, Designing, Engineering, Installation

& Commissioning of BMS, Access Control

System, Public Address System, Fire Alarm

System, CCTV, IPTV & IPClock for high-rise

buildings (Hospitals, Hotels & Banks). Good

Skills in construction management and

leadership, team building, effective

communication and conflict resolution.

PROFESSIONAL SKILLS

Expert in: Auto CAD 2021, BMS, Access Control

System, Public Address System, Fire Alarm

System, CCTV, Engineering, Installation &

Commissioning

REACH ME AT:

Mobile: +966*********

Address: Dammam 32242, Saudi Arabia

Email: adp7tz@r.postjobfree.com

WORK BACKGROUND

* Maintenance of BSS Network of Trichy SSA with minimum interruption - E1 testing, Hardware Verification through OMCR.

* Performance Analysis & traffic monitoring (Drop call rate, Handovers and TCH congestion) - Half & Full E1 bypass.

* Extending of external alarms to OMC-R and periodical checking of alarms by creating alarm conditions manually - Making Cross connections on RRI, E1/T1, FIFA and FIPA transmission cards.

* Periodical measurement of radiating power & VSWR using ANRITSU and necessary efforts to maintain the values as per the standard - VSWR/RSSI Rectification.

* Carried out BTSs swapping (Motorola BTS to Nortel BTS) in Trichy SSA during Phase IV expansion BSNL GSM network - SWAPING, SEGMENTATION, CABEX, TRX-ADDITION.

* Carried out integration of Nortel BTSs and BSC during Phase IV expansion BSNL GSM network. O&M Engineer

Integrated Wireless Solutions Pvt. Ltd., Tamil Nadu, India Apr 2005 - Apr 2007

EDUCATION BACKGROUND

Syed Ammal Engg. College., Anna University, India

Bachelor in Engineering (Electronics & Communication)



Contact this candidate