Post Job Free

Resume

Sign in

Electrical engineer

Location:
Sikkim, India
Salary:
8lac
Posted:
February 07, 2022

Contact this candidate

Resume:

CBSEBoard

CurriculumVitae– Kaushal Sharma.

EDUCATION

ADDRESS Mandir Line

Behind SNOD Petrol

Pump,S-152 Singtam

East Sikkim,India

MOBILE

+919*********

E-MAIL

adp5qz@r.postjobfree.com

MSMT

Mangalam School of

Management &Technology

New Delhi

CCCT

Centre for Computers

&Communication

Technology South Sikkim

Singtam Govt. Senior

Sec. School East Sikkim

B-TECH

Bachelor of Technology in Electrical &

Electronics

Diploma

Diploma in Engineering in Electrical

& Electronics

10th

Secondary School Certificate Examination

COMPETENCIES

Hydro Power

Electrical Equipment

Maintenance

Operation

&Maintenance

Testing

& Commissioning

Project Management

WORK-EXPERIENCE(7YEARS)

Present Profile: Feb-2021 to Dec-2021.

Company Name: TRANSGUARD GROUP

Project Name: Emirates Flight Catering, Terminal - 1 Dubai International Air Port.

Designation: Security Officer

Responsible for performing all security related duties as assigned on a daily basis by the management.

SKILLS Making accurate administrative records of any security related incidents. MSProject

AutoCAD

MSOffice

Keil,Proteus,Step7Lite

Circuit Layout Design

PLC ladder Programming

Monitoring and responding to CCTV, intruder detection and fire alarm. systems.

Previous Profile : Feb-18 to Jan-2021

Company Name: GREENKO GROUP

Project Name: Sneha Kinetic Power Projects Private Ltd. (Dikchu 2 x 48 MW, H.E.P East Sikkim).

Designation: Officer (O&M) HYDRO

• To carryout testing, maintenance, trouble shooting & modifications for following components of project:

• Generator step-up transformers 11 KV/ 132 KV, 132 KV/11 KV Power Transformers, Unit Auxiliary transformers & Excitation Transformers and132/400kv GIS Substation.

• 132/400 KV Line Protection system (MICOM relays), Control systems

(Field devices, networking, SCADA & Automation), PLCC system, HVAC system, Fire Fighting System, cooling water system, Illumination system, LP supply air system, EOT crane, draft tube gate gantry and Drainage & Dewatering systems at Power House.

• Conducting testing of Protection panel of Generator,Turbine Auxiliary with instrumentation and compile with electrical system.

• To carry out Start-up & Shut-down operations of machines as per the Schedule & reservoir level.

• Leads & supervise the electrical section in maintenance related jobs, provide assistance in troubleshooting, issue reports on major failures & recommends suitable actions to minimize or eliminate reoccurrence of problems

• Documentation of Energy and Generation Reports, Import and Exports power, River Water Discharge and Break down analysis report.

• Preparation of Daily, Weekly & Monthly Generation Progress report and submit to Head Office & all concern agencies.

• Arrangement and planning of everyday schedule e man power and material arrangement for execution of project as per schedule.

• Making changes in the scheduled plant generation as per the changes in the river inflow and taking approval from SLDC.

• Ensure that all the parameters are being monitored & recorded in logbooks at control room & different locations of the plant.

• Co-ordinate with personnel stationed at DAM, De-silting Basin,

• Forebay & Switchyard to ensure smooth operations. Past

Ex Past

Experience:

Electro-Mechanical

Department

Dec-16to Dec.17.

@ TeestaUrja

Stage-III –

H.E.PPRO

JECT-1200

MW H.E.P

NorthSikkim

perience:

Electro-Mechanical

Department

Dec-16to Dec.17.

@ TeestaUrja

Stage-III –

H.E.PPRO

JECT-1200

MW H.E.P

NorthSikkim

Previous Experience:

Hydro Operation &

Maintenance,Feb2018 to

Jan2021 @GREENKO GROUP

• Ensure all the equipment of the plant are functioning healthy by constant monitoring of different parameters.

• HT and LT overhead AC lines, preventive maintenance, planning and execution.

• Testing and commissioning of protection relays and its operational check.

• Check it’s all commissioning operation al check having:-Checking loose connection, Checking internal circuit continuity checks, Checking measuring current loops, Checking insulation level.

• Checking all PCCs, MCCs, power protection device likes. ACB, MCBs, relays contactors, fuses and its operational check.

• All relays to be checked and take non line and also to be checked the tripping condition.

• Planning and scheduling Preventive & Periodic Maintenance for O & M.

• Handling 40 man powers including contractors in-charge and safety team.

• Developed tools for scheduling based on reservoir levels & river discharges

, developed tool for cross verification of deviation account billed as per ERPC.

• Maintenance management by developing & implementation of electrical maintenance schedule for all equipment for handling breakdown

& improving uptime & keeping record of the regular maintenance activities by adhering to the daily, weekly, monthly & yearly checklists. Past

Experience:

Electro-Mechanical

Department

Dec-16to Dec.17.

@ TeestaUrja

Stage-III

H.E.P PRO

JECT-1200

MW H.E.P

North Sikkim

Company Name: Giriganga Infra solutions Private Ltd Project Name: Teesta Urja Stage-III 6 X 200 MW H.E.P North Sikkim Designation: Associate Engineer (Electrical) Electro- Mechanical Department (Dec-16 to Dec-17)

To carry out testing, commissioning, maintenance, troubleshooting & modifications as System In-charge for following components of project:

• Check the work/product of the contractors with reference to approved drawings and raising punch points if any discrepancy/non-compliance is found w.r.t erection, commissioning, operation of all the systems in powerhouse, 400 kv GIS & potyard.

• Monitored special preservation activities and maintenance of ElectroMechanical equipment during the pre-commissioning period.

• Conducting erection & testing of Protection panel of Generator step up transformers 15KV/ 400 KV, Power Transformers, Unit Auxiliary transformers & Static Excitation Transformers.

• Instrumentation and compile with electrical system.

• Erection, testing & commissioning of 15 kv busduct, current transformers

& potential transformers.

• Erection, testing &commissioning of400 kv potheadyard.

• Erection, testing & commissioning of service station transformer and auxiliary transformers.

• Installing electrical panel like UCB, UAB, SAB, DC battery charger, NGT and LAVT,knowledge in PLCC protection &data/ speech panel.

• Co-ordination with PGCIL officials/ engineers at remote end substations with respect to line protection, PLCC, special protection scheme, voice & data communication issues.

• Carrying out the installation of Cable Tray for Control and Power cables in Power House and Potheadyard.

• Testing of 11KVsynchronous generators(Alternator)&11KVswitchgear.

• Performing erection of Lighting system and communication system in Power House Complex and Street Lighting, Cooling water system, D & D System and fire fighting system, HP Injection system, Accumulator, OPU system and oil Leakage unit.

• Analytical thinking with effective talent to identify, improve and can work incomplex stage.

• Ability to work with a team of dedicated professionals for achieving the deadlines for the execution of work.

Past

Experience:

Electrical Department

Aug-13toDec.16

@ Teesta

UrjaStage-III–

H.E.PPROJECT

-1200MW

H.E.P North

Sikkim

Company Name: Abir Infrastructure Private Ltd

Project Name: TeestaUrjaStage-

III 6X200MW H.E.P North Sikkim.

Designation:Jr.Engineer(Electrical)

• Planning & scheduling assignments to achieve pre-set goals with in time parameters. Formulating long term/short term strategic plans to enhance operations.

• Arrangement and planning of everyday schedule manpower and material arrangement for execution of project as per schedule.

• Trouble shooting and maintenance of Tamrock (SANDVICK), Meyco Potenza, grout machine, diesel generators with AMF Panel, Crusher plant

(Make: SISCO), batching plant (Make: Graves and Gammzen), concrete pump, welding machines.

• Troubleshooting and calibration of load distribution panels, V.F.D, vibrator

(C.G), Mody sludge pump, R/O plant, Hilti, load cell & batch controller.

• Function & selection of T.P.N, MCB, MCCB, RCB, ELCB, MPCB, Fuse, contactor, Timer, Relay & NO, NC switch.

• Problem solving of power contactor (Siemens), auxiliary contactor, overload relay and CT & PT.

• Safe operation and maintenance of diesel power station.

• LT switchgear with protection system using numerical and electromagnetic relays & provision for interlocking (Make: AREVA).

• Safe operation and maintenance of motors and power transformers.

• Knowledge in star delta & DOL Starter Wiring & Control Circuit.

• Ability & well experience to learn, control & wiring diagram.

• Maintenance of Tube Lights, HPSV lamps, Halogen Lights & MH lights.

• Both practical as well as theoretical knowledge of different electrical & electronic Instruments.

• Selection of power & control Cable base don (1core, 2core, 3core,3. 5 cores, 4 core etc. Alu & Cu)

• Responsible in checking all the fire fighting system particularly in the electrical matter.

• Importance of safety in underground works & working places.

• Provide the proper preventive maintenance of machines.

• Maintaining of logbook, checklist & daily site progress.

• Analytical thinking with effective talent to identify, improve and can work in complex stage. Declaration

I, Kaushal Sharma, hereby declare that the information contained herein is true and correct to the best of my knowledge and belief. Thanking You!

KAUSHAL SHARMA.



Contact this candidate