CURRICULUMVITAE
K.MOHAMMEDUBAITHULLAH
KathbadaLane,Chennai
INDIA:+919*********
EmailID:********@*****.***
QUALIFICATIONS
● NationalApprenticeshipinElectrical
SouthernRailway,Chennai
● BachelorDegreeinElectricalandElectronicEngineering(4yrs) ThiruvaluvarUniversity.
CAREERSUMMARY
SeekingapositionasElectricalSupervisor/ElectricalSpecialistwhichwil makeuseofwideexperiencethecapacitytogetthejobdone.IHave16yrsof ExperienceinElectricalMaintenanceandCommissioningFieldinVariousIndustries
(Oil&Gas,Petro-Chemical,Refinery,PowerGenerations) Multilingual–English,Arabic,Tamil,Hindi.
ManagingandresponsibleforHSEmattersforassignedproject,majorHSEfocal pointinproject,home,officeandonsiteAreaResponsiblePTW,LOTO,NEARMISS, UNSAFEACT,PBO.
•RoleRepresentative:ISO/DE-ISO,EIC,EPTW,LOA
KEYSKILLS:
Experienceduseroffollowingcomputerprogramsandsystems:
MicroSoftWord,Excel,PowerPoint
TRAINING
OPITOapprovedTBOSIET(102944/2017)
OPITOapprovedBasicH2STraining
ADNOCUZ750PTWPerformingAuthority
Preparation,AuthorizationofOperatingLV/HVApparatusCertifiedbyAPAVE
IsolationandCancelationofElectricalEquipment(HV/MV/LV)approvedby MalaysianTrainingCenter(P436EE239CO22)
LeadershipandSupervisorTrainingProgramCertificateNo:NB119013473705
(ILM–TraintheTrainer,QualityControl,CulturalAwareness,HSSE,PTW&TSTI)
CompEX(CertificateNo:11/0313/3/1)OrganizedbyBASEEFA&ASA ConsultingEngineersfromU.K
BasicFirstAid,FireFighting,ConfinedSpaceEntry,HazardIdentification,Working atHeight,PTW&LOTO
Page2of2
EMPLOYMENTEXPERIENCE
July2019–Tilldate
ChennaiPetroleum CorporationLtd.(REFINERY)for
K.NPowerServices(INDIA)
ElectricalSupervisor
CarriedOutRoutineInspectiononalHV/LVElectricalEquipmentsand CorrectiondoneasperSOP
Supervisor&MonitorMaintenanceActivitiesonPowerandDistribution Transformers(33MVA–11kV/7.7kV)(2MVA-6.6kV/0.415V)
Supervise&MonitorMaintenanceofSwitchGears(11kV,6.6kV,0.415kV), Transformers(ONAN,ONAF),Motors(HV/LV),UPS,BatteryChargers,EDG’s andit’sHMIControlPanels
CarriedOutMajorOverhaulandBearingReplacementofLVMotors
TestingandCalibratingBi-MetalicOverloadrelays(OLR)
WeeklyChecksonEmergencyDieselGeneratorandCarriedoutStart&RunTest
ExperiencedonHV/LVSwitchBoards(PCC,MCC,EPMCC,ELDB,LDB)andits ProtectiveRelays(AlstomMi-Com,ABBSPAJ)
UnderstandandKnowledgeofIEC/ANSIStandards
ExperiencedonHandlingElectricalTestingEquipments(Ductor,HighVoltage Tester,DCResistanceTester,AVOmeter,Tong-tester,MovingIron/MovingCoil MeasuringMeters)
HandlingofalElectricalSafetyEquipmentsandDocumentation(Safety Padlocks,PTW’s,TRA,JSA’s,TBT,EIC)
ComplywithHSEPolicyandImplementingBOPproceduresonWorking Activities
TestedandImproveEarthResistanceofalEarthPitsandRecordingit’sValue
AuthorizedElectricalLicenseHoldertoCarryOutWorkonMV/LVEquipments issuedbyStateGovernment
Oct2017–July2019
ADNOCUZ750Project(Abudhabi–OFFSHORE)for
PetrofacInternationalCo.
ElectricalSupervisor
Experiencedon33kVGIS,6.6kVAISSwitchBoards&LVSwitchBoardsandit’s ProtectionRelay
Instalation,Commissioning&TestingofElectricalEquipmentsonHV SwitchgearsConsistsofGIS/AIS/ACB,LVMotorControlCenter,HT/LTMotors, 33kV/6.6kV&33kV/0.415kVPower/DistributionTransformers
Operation&MaintenanceSupportonHV/LVMotors,Power&Distribution Transformers,DryTransformers(33kV/6.6kV-25MVA,33kV/0.415kV– 2.5MVA)
ProvideMaintenanceSupportonBatteryChargers,UPS,BatteryBanks,VFD’s, HVACPanels,HCPPanels,AnnunciatorPanels,CathodicProtectionPanels& EDG’s
CarriedOutISO/De-ISOofLVequipmentswithLOTOProcedures Page3of3
CarriedOutPredictiveMaintenanceonCriticalequipmentsandcorrective actionstoavoidbreakdownandreducingbreakdowntime
Read&UnderstoodofElectricalProtectionRelayandMicroprocessorbased Relay(SiemensSIPROTEC,SchneiderSEPAM,GEMultilinRelay,Siemens SIMOCODEPRO)
TroubleShootingonPlantsElectricalEquipmentstodeterminetheirCauseand recommendsOptionsforeliminatingSuchProblems.IncludeCarryingouttests onequipments
Capableofguiding/leadingtheelectricalmaintenanceteamandimplementing thebestmaintenancestrategyfortheplantincludingHighVoltageof 6.6kV/0.415kVsystem
ConductingSafetyauditwithinthedepartmentandensuringthecompliance fromaltheemployeesandupdatingtheChecklistandauditreports
ISO/De-ISOdocumentation,QualityCircleformationfordetectingproblemsand solvingformshopflooremployees.
Co-ordinationwithVariousdepartmentsforSmoothfunctioningofthe equipmentbyfeedbackandsuggestionfromthem
DailyPowerMonitoring,Calculationsandreportingatmonthlybasis
AwarenessofHazardousAreaClassificationandSelectionofElectrical Equipments
Mar2017–Sep2017
CAMBODIANENERGYLIMITED(100MW)–CAMBODIA
ElectricalSupervisor
SupervisingandMonitoringtheElectricalActivitiesandAssigningManPowers totheWorkTask
CarriedOutMaintenanceandTroubleShootingofDOLStarter,Semi
/AutomaticStar-DeltaStarter,RotorResistanceStarter
CarriedOutMaintenance&TroubleShootingofDCMotorsandit’sStarters
CarriedOutInspection&OperationsofConveyors,CoalCrushers,Vibrators, AshUn-loaders,AirCompressor,AirDryers,BucketElevators,EOTCranes
ParticipateandCo-OrdinateswithVendorduringPlantShutdown.
ProvideTechnicalInputtoFacilitateandAssistVendorsduringTesting
ManageSparePartsandConsumableMaterialsandBilofMaterials
EvaluatingElectricalEquipment’sandSystemPerformanceandtaking NecessaryActions
PerformOtherRelatedJobActivitieswithOtherdisciplines
ReviewElectricalSLD,SchematicDiagram,BlockDiagrams&CivilDiagrams
ConductGeneralInspectionsandSiteReadiness
ParticipatingWeeklymeetings&discussingTechnicalIssueswith Superintendent
May2015–Dec2016
ChennaiPetroleumCorporationLtd.(REFINERY)for
JAYKRISHNAIndustriesLimited(INDIA)
ElectricalSupervisor
Page4of4
PrepareWorkPermit,TaskRiskAssessmentsandWorkProcedure
PlanandEvaluatetheElectricalManPowertoCompletetheTaskSafely
CarriedOutISO/DE-ISOonHV/LVEquipments
ProvideTechnicalSupportonMaintenanceofUPS,Motors,Transformers, EDG,SwitchBoards(PCC,MCC,PMCC,LDB&ELDB’s)VFD’s
ReviewofElectricalDrawings(Schematic,Single-Line)andKnowledgeof ProtectionRelays(Alstom Mi-comRelay,ABBSPAJRelay)
Preparing&gettingApprovalofShiftSchedules,TimesheetsandLeave SchedulesandgettingApprovalfromClient
ConductingSafetyMeetingswithTechniciansandwithManagements
GuideTechnicianonMaintenance&TroubleShootingofElectricalActivities
ConductInternalAuditwithTechniciansondocumentations,LeaveSchedules
ConductingDailyTBTandSafetyReviewofthePlantequipments Nov2013–April2015
SABIC-KEMYA(Petro-Chemical)ofJALInternational
Co.(KingdomofSaudiArabia)
ElectricalSpecialist
Plans,RepairsandOverHaulofElectricalEquipmentsandSystem
Co-ordinatesandFolowupNewElectricalEquipmentInstalationand Modifications
ProvideMaintenanceSupport&TroubleShootingofSoftStarter,AC/DCDrive, AC/DCMotors
CarriedOutMaintenanceonHighVoltagedisconnectSwitches,SwitchBoards, EmergencyDieselGenerators
Testing&CalibrationofBi-metalicOverloadRelaysandGEMotorManagement RelaysMM1&MM2
Analyses,PerformanceforElectricalServicesandProduceReportto Supervisor
InvolvedinPlantCommissioningActivitiesRFIMechanicalCompletionWalk downsofElectricalEquipmentsInstalations
WitnessingofPre-Commissioning,CommissioningandPlantStart-up Activities
InvolvedinTestingActivitiesHighVoltageTest,Stability-test,C.BContact ResistanceTest,InsulationResistanceTestofC.T,V.T,Cables&CircuitBreaker
AttendedTrainingScheduleofConfinedSpaceEntry,WorkingatHeight,PBO, LSR,SafetyRules,LOTO
WitnessingFunctionalTestofSwitchBoards(PCC,MCC)Modules,Switch- Gears
CarriedoutMaintenanceofMV/LVSwitchGears,Transformers,Motors,UPS, BatteryChargers,LVGenerators
WeeklyInspectionofSubstations,Transformers,SwitchYard,LVGenerator Rooms
AnalysesRootCauseofElectricalFaultsandTroubleShootingofElectrical Equipments
Page5of5
ConductingdailyToolBoxtalk,PBOandAttendingWeeklySafetyMeetings May2011–Sep2013
QatarShellGTLProject(GASPLANT)forQNFSCo.
Sr.ElectricalTechnician
Plans,RepairsandOverHaulofElectricalEquipmentsandSystem
CarriedoutMaintenanceofMV/LVSwitchGears,Transformers,Motors,UPS, BatteryChargersandIndustrialLightings
CarriedOutMaintenanceon6.6kVHighVoltageContactor,DryTransformer, EOTCranes,HeatTracing,JunctionBoxes,SafetySwitches
ConductBatteryDischargeTest,BatteryInspection,BatteryBankPM
AnalysesRootCauseofElectricalFaultsandTroubleShootingofElectrical Equipments
Co-ordinatesandFolowupNewElectricalEquipmentInstalationand Modifications
Analyses,PerformanceforElectricalServicesandProduceReportto Supervisor
InvolvedinPlantCommissioning&Start-UpActivitiesRFI,MCWalk-downson HV/LVMotors,JB’s,HeatTracing,PlantLightingFixtures,ElectricalDB’sand VFD’s
InvolvedinTestingActivitiesHighVoltageTest,Stability-test,C.BContact ResistanceTest,InsulationResistanceTestofC.T,V.T,Cables&CircuitBreaker
WitnessingFunctionalTestofSwitchBoardsPCC,MCC,Modules,Switch Gears,MotorSolo-RunTest
AttendedTrainingScheduleofConfinedSpaceEntry,WorkingatHeight,PBO, LSR,SafetyRules,LOTO
AttendingandConductingdailyToolBoxtalkandWeeklyHSEmeetings Mar2010–Jun2010
RASGAS&ORYX(GASPLANT)forQ-CONin(QATAR)
ElectricalSupervisor
SupervisingandMonitoringElectricalActivities
ExecuteandAssigningManPowerstoClient
PreparationforTestingElectricalEquipmentHV/LVMotors,HV/LV Transformers
ConductandInspectionwithQCPersonnelforModificationWork
InvolvedinTurn-keyShutdownofPlantSubstations
TestedandUpdatedGroundResistanceofEarthPitsinSubstations
ProvideAdequateLightingonConfinedSpaceEntryforMechanicalParty. Apr2002–Jun2007
ChennaiPetroleumCorporationLtd(REFINERY)for
ElectricalEngineeringServices(Chennai-INDIA)
Sr.ElectricalTechnician
Page6of6
CarryingOutOperation&MaintenanceofSwitchGears(11kV,6.6kV,0.415kV), Transformers(ONAN,ONAF),Motors(HV/LV),UPS,BatteryChargers,EDG’s andit’sHMIControlPanels
CarriedOutRoutineInspectiononalHV/LVElectricalEquipmentsand CorrectiondoneasperSOP
CarriedOutMaintenanceonPowerandDistributionTransformers(33MVA– 11kV/7.7kV)(2MVA-6.6kV/0.415V)
CarriedOutMajorOverhaulandBearingReplacementofLVMotors
TestingandCalibratingBi-MetalicOverloadrelays(OLR)
WeeklyChecksonEmergencyDieselGeneratorandCarriedoutStart&RunTest
ExperiencedonHV/LVSwitchBoards(PCC,MCC,EPMCC,ELDB,LDB)andits ProtectiveRelays(AlstomMi-Com,ABBSPAJ)
UnderstandandKnowledgeofIECStandardRelay
ExperiencedonHandlingElectricalTestingEquipments(Ductor,HighVoltage Tester,DCResistanceTester,AVOmeter,Tong-tester,MovingIron/MovingCoil MeasuringMeters)
HandlingofalElectricalSafetyEquipmentsandDocumentation(Safety Padlocks,PTW’s,TRA,JSA’s,TBT,EIC)
ComplywithHSEPolicyandImplementingBOPproceduresonWorking Activities
TestedandImproveEarthResistanceofalEarthPitsandRecordingit’sValue
AuthorizedElectricalLicenseHoldertoCarryOutWorkonMV/LVEquipments issuedbyStateGovernment