M.Sachudhanandham
+91-959*******, +*** 708-***-****
Succinctly
With sharp skill set and experience in the field of electrical technology and seeking for a challenging position, I bring to the table a unique yet powerful combination of expertise to meet the ever growing need in the field.
Professional Designation
Electrical Commissioning Engineer at Voltech Engineers Pvt Ltd (2014 – 2018) Technical Manager for Voltech Nigeria Operations (2018 – till date) Total Experience: 7 years.
Job Description
Testing and Commissioning of electrical equipment in both switchyard, switchgear and GIS at various voltage levels includes and also operation & maintenance, yearly shutdown maintenance projects.
Measuring and monitoring equipments like CT, CVT (PT).
Power equipments like Power Transformer, Generating transformer, Isolation transformer, Shunt Reactor, Motor and Generator.
Control equipments like Circuit breaker, Dis connector.
Protection equipments like Lightning arrestor, Surge arrestor.
Transmission equipments like Distribution transformer, Power cable
Protection relays and auxiliary relays.
Communication equipments like Wave trap.
Knowledge on control panel scheme logic checking along its correctness.
Knowledge on compiling control cable schedule for the bay equipments and its protective measures with respect to the scheme logics.
Knowledge protective relay configuration and checking.
Co-ordination with client on work and personnel safety procedures, daily meetings on work progress status updates and pep discussion
Supervision for shut maintenance works installation of HT, LV panels, and Transformer.
Project handling technical team lead for installation, testing and commissioning.
Co-ordination with the erection team, civil department for minimising the obstacles in the work progress.
Operation and Maintenance
Operation and maintenance of substation 400/220kV substation
To carry out preliminary inspection of major incidence of substation and lines
EHV spare forecast and to define the inventory level required for healthy operation.
EHV related technical change implementation tracking and support the site in implementation
Support quality team in technical due to diligence audit of O&M of HV/EHV systems.
Documented the standard operating procedures including operating and maintenance plan, work instructions and specifications.
Maintain the logbook, calibration reports, to record the operation and maintenance. Education
Under Graduation
2010 – 2014 Bachelor of Engineering
Govt college of Engineering Burgur Department of
Electrical and Electronics Engineering.
Performance acquired: 6.6 CGPA.
Schooling
2009 – 2010 Completed my Higher secondary class with 76.6% at Government Higher Secondary School, Valapandal.
2007-2008 Completed my High school with 86.6% at Government High School, Vadamanappakkam.
Projects Worked
In India
Project: IOCL Refinery Paradip, Odisha.
Client: Mukand Pvt Ltd
End Customer: IOCL
Generator Plant of capacity 366MW.
Method of statement preparation activities.
Steam turbine generator and gas turbine generator were tested and commissioned.
50MVA 66/6.9-6.9 KV Transformer Tested and Commissioned.
2MVA 6.6/0.433KV 10 no’s Transformer Tested and Commissioned.
6.6KV HT Panel 10 cubical and 415V LT Panel 15 no’s Tested and Commissioned.
6.6KV HT Motors 5 no’s Tested and commissioned.
GE650 relay tested and commissioned.
Test reports preparation activities.
Maintenance: IOCL Refinery Paradip, Odisha.
Roll: Senior commissioning engineer - Operation & Maintenance Client: Mukand Pvt Ltd
End Customer: IOCL
Operation and maintenance for 11Kv & 6.6Kv switchgear panel.
Operation and maintenance for 50MVA Generator transformer, HT Motors.
Maintain the logbook, calibration reports, to record the operation and maintenance. Project: Bhushan Power & Steel Plant Odisha Jharsuguda Roll: Senior Commissioning Engineer
Client: ABB
End Customer: Bhushan Power & Steel Plant
Method of statement preparation activities.
6.6 KV HT 42 cubicles maintenance cleaning, visual inspection, breaker manual operations, rack in rack out, ct, pt, bus bar testing, schematic check and modification.
REM650, REF650 Relay tested.
Test reports preparation activities.
Project: Gokarna – 400/220/33KV Substation, West Bengal. Roll: Senior Commissioning Engineer
Client: ALSTOM T&D INDIA
End Customer: WBSETCL
Method of statement preparation activities.
Tested and commissioned 11 nos. of 400KV bays, 4 nos. of 220KV bays, 2 nos. of 33KV bays comprising CT, CVT (PT), Circuit Breaker, LA, Wave trap and Disconnector.
Tested and commissioned 2 x 315MVA Power Transformer of voltage rating 400/220/33KV.
Tested and commissioned 2 x 15MVA Distribution transformer of voltage rating 33/0.433KV.
Tested and Commissioned 1 no. 80MVAR Shunt Reactor.
Tested and commissioned 11 nos. C&R panels for 400KV bays and 4 nos. of C&R panels for 220 KV bays comprising a double main bus and single transfer bus protection scheme.
Preparation of control cable schedule for the entire substation equipment along with scheme logic modifications and dis connector interlocks.
Tested and commissioned 2 nos. C&R panel for 33 KV bays.
Tested and commissioned ACDB, MLDB and DCDB system.
Test reports preparation activities.
Project: Gokarna – 400/220/33KV Substation, West Bengal. Roll: Senior Commissioning Engineer - Operation & maintenance. Client: ALSTOM T&D INDIA
End Customer: WBSETCL
Operation and maintenance for 400/220/33Kv Substation 3 months period after commissioning.
Annual Maintenance: 33/11/KV Switch gear Vision Spong Iron Pvt Ltd,west Bengal Roll: Senior Commissioning Engineer
Clint & End Customer : Vision Spong Iron Pvt Ltd,west Bengal.
Method of statement preparation activities.
10MVA transformer maintenance visual inspection, cleaning, cable termination end check, earthing check, insulation resistance test checked.
33KV VCB panels maintenance visual inspection, cleaning, tightness of control wires, vcb manual rack in & rack out and testing of breaker ct, pt, bus bar.
Numerical and electromagnetic relay tested like feeder and motor protection REF615
& P220.
Test reports preparation activities.
Projects Bakoro Steel Plant Jharkhand
Roll: Commissioning Engineer
Clint: S.P.Enterprises
End Customer: BSL
Method of statement preparation activities.
11 KV & 6.6 KV switch board feeder tested and commissioned.
2 no’s Auto & 2 no’s Converter Transformer tested and Commissioned.
REF615, REM615 tested and commissioned.
HT Motor tested and commissioned.
Test reports preparation activities.
Project: Rammam Hydel Plant West Bengal
Roll: Senior Commissioning Engineer
Clint: ABB India Ltd
End Customer: WBSEDCL
Method of statement preparation activities.
132 KV Hybrid ABB GIS tested and commissioned.
10MVA Single phase transformer 3no’s tested and commissioned.
3MVA 33/11 KV Station Transformer 2 no’s and 33KV Earthing Transformer 2 no’s tested and commissioned.
33KV GIS tested and commissioned.
11KV switch gear tested and commissioned.
Test reports preparation activities.
Project: Rammam Hydel Plant West Bengal
Roll: Senior Commissioning Engineer – Operation and Maintenance Clint: ABB India Ltd
End Customer: WBSEDCL
Operation and maintenance for 132KV & 33Kv GIS & 11Kv Switchgear panel.
Operation and maintenance for 10MVA power transformer and earthing transformer.
Above are1months period from after commissioning. Project: IOCL Refinery Haldia
Roll: Senior Commissioning Engineer
Clint: ABB India Ltd
End Customer: IOCL
132 KV Switch Yard 2-Bay with Bus section tested and commissioned.
50MVA 132/11 KV Power transformer tested and commissioned with OLTC, RTCC Commissioned.
11KV switch gear tested and commissioned.
Test reports preparation activities.
Project: 132/33KV Switch yard Chitra, Jharkhand
Roll: Senior Commissioning Engineer
Clint: AKS Construction and Private Ltd
End Customer: JUSNL
Method of statement preparation activities.
132 KV Switch Yard 4-Bay with Transfer bus Tested and commissioned.
33 KV Switch Yard 4-Bay with Transfer bus Tested and commissioned.
20MVA 132/33 KV Power transformer Tested and commissioned with OLTC,RTCC.
Test reports preparation activities.
Project: 132/33KV Switch yard Chitra, Jharkhand
Roll: Senior Commissioning Engineer - Operation & Maintenance Clint: AKS Construction and Private Ltd
End Customer: JUSNL
Operation and maintenance for 132/33Kv Substation 1 months period after commissioning.
Onsite Projects:
Project: Turn Around Preventive Maintenance 2018
Roll: Supervisor
Client: AARKAY International
End Customer: Salalah Methonal Company (SMC) - Oman
Method of statement preparation activities.
Preventive Maintenance Activities of Switch Board 415V, 3.3KV, 11KV.
Preventive Maintenance Activities of 415V & 3.3KV Motors.
Preventive Maintenance Activities of Generator NGR and LBS. Project: 1X 133.97MVA, 17.75 KV,50 Hz, Sapele Power Plc Roll: Erection Supervisor and site coordinator
Customer: M/s Sapele Power Plc, Delta State, Nigeria
Installation and commissioning done for new Rivex Digital Static Excitation System with replacement of old excitation.
Retrofit of mechanical governing system to Woodward free electronic Governing system Installation and commissioning done.
Operation and Maintenance for above system 3 months from the date of commission. Project: 33kv/11kv/415 V Substation
Roll: Senior Commissioning Engineer
Customer: M/s Olam Animal Feed, Ilorin
Retrofit of Alstom P642 Differential Relay installation and commissioning done.
Installation and commissioning of VMC 100 O/C, E/F Relay
Installation and commissioning of Schneider Vamp 11 V U/V O/V Relay. Project: 11KV/415V Substation, Lagos
Roll: Senior Commissioning Engineer
Customer: M/s PZ Wimar, Ikorodu, Lagos, Nigeria
Annual maintenance for 3MVA 11/415V transformer.
Annual maintenance for 11KV HT Panel and 415V LV Panel.
Annual maintenance for Siemens 7sj8011 transformer protection relay Project: 11KV/415V Dikko Farms, zaira, Kaduna, Nigeria Roll: Supervisor
Customer: Olam Dikko Farms
Supervision for Installation of new plan retro fitting project like cables installation and termination, 681KVA and 500KVA Generator installation, Overhead line pole erection and commissioning the whole system.
Project: 11KV VCB Panel
Roll: Commissioning Engineer
Customer: M/s Aspira Nigeria Ltd, Kano, Nigeria
Testing and commissioning of 11KV VCB Panel
Project: Steam turbine Generator Assessment
Roll: Commissioning Engineer
Customer: M/s Egbin Power Plant – Ikoroadu Lagos.
Assessment test for Unit-3 Steam turbine generator, transformer, AVR and control panels to conform the equipment’s working condition & healthiness. Other Activities:
BOQ, SLD, Costing preparation for the projects and technical/commercial meeting between customer, clients and sub-contractors.
Kits Handled
High Potential Injection : Prayog, Sudharson
Insulation Resistance Tester : Kyoritsu
Loading Transformer : Sudharsan
Secondary Injection
Single Phase : Sudharsan
Three Phase : OMICRON CMC 356
Contact Resistance Meter : ELTEL, SCOPE
Time Interval Meter : SCOPE
Transformer Winding Resistance : SCOPE, ELTEL
Software Handled
Micom S1Studio AGILE for ALSTOM relays
PCM 600 ver. 2.4 and Wave Win for ABB relays
Test Universe for OMICRON Kit
Numerical Relays Handled
ABB
1. Motor Protection : REM 650
2. O/C & E/F Protection : REF 615
3. Transformer differential : RET520
4. Generator Protection : REG630
ALSTOM
1. Transformer Differential Protection : P643, P642 2. Directional O/C & E/F Protection : P143
3. Voltage Protection : P141
4. Busbar Protection : P743
Personal Details
Name : Sachudhanandham M
Date of birth : 15. 06. 1993.
Gender : Male
Father’s Name : Manavalan N
Mother’s Name : Rajeshwari M
Nationality : Indian
Language’s known : English, Tamil & Hindi.
Permanent Address : No:668 A1, Ramalinga nagar, opposite housing board, cheyyar thiruvannamalai dt, Tamilnadu-604407.
E-mail : ado6nm@r.postjobfree.com
Declaration
I hereby declare the above furnished information is true to the best of my knowledge and would prove as best asset to the organisation.
Date :
Place : Chennai M.SACHUDHANANDHAM