With reference to the above subject, I came to know that you have few vacancies in your company. I am herewith submitting my candidature for the same for your kind perusal.

Received a certificate of “Boiler Operating Engineer (BOE)” from Government of Andhra Pradesh Boilers Department.

Received a certificate of "Energy Auditor" from Bureau of Energy Efficiency is

an agency of Central Government of India.

As regard my experience, I am working as “Control Room Engineer” in IBRI power plant for ACWA power under NOMAC O&M (OMAN) of 1509 MW since November 2018 and having a total experience of 11years and 2 months. I have good exposure at Commissioning operational and performance practices like unit start up, shut down, emergency handling, monitoring parameters in field as well as in DCS and comparing those with baseline data. I have good knowledge of protections, logics and conversant with handling emergency situations like black out, trips.

Actively involves in ALSTOM GT26 commissioning activities.

Undergone GE9FA liquid fuel commissioning upto baseload

Having experience on GE9FA,9E ALSTOM 26and 13E2 machines

Actively involved in combustion and major overhaul inspections of GE 9FA,9E gas turbines.

Worked as a Energy Manger during annual energy audit and having good knowledge in operating GATE CYCLE and EBSILON software's in creating models and calculating the performances of the cycles.

Ready to join in 15 days from the date of appointment and holding a visa for oman valid upto November 2023

Thanking you sir,

Yours Sincerely,

Date: 6/25/2021,

Place: India. (BALA KRISHNA REDDY.B)

curriculum vitae

B. BALA KRISHNA REDDY

Contact: +919********* MailId:adnl2b@r.postjobfree.com mailto:adnl2b@r.postjobfree.com

Objective:

To work for a world-class organization where I can utilize my technical knowledge and potential for the companies’ growth and fulfill organization’s goals and objectives.

Present Experience:

●Working as Control Room Engineer for a combined cycle power plant for ACWA Power under NOMAC IBRI power plant of 1509 MW from November 2018 to present.

●Actively involved in commissioning activities of ALSTOM GT-26 and ST

●Worked for ALSPA and Ovation softwares having good knowledge in ovation logics study.

●GT Machine configuration :ALSTOM 26Controgas control system(4xGTs) each of 275MW

●HRSG: Triple pressure boiler (Reheating 4XHRSG)

●ST Machine configuration : ALSTOM make(2xST)each of 302MW

Previous Experience:

●Working as Control Room Engineer for a combined cycle power plant at GentingLanco private India Limited of 390 MW from September 2017 to October 2018.

●GT Machine configuration : GE 9E (Mark 6e control system)2xGTs each of 120MW

●HRSG: Triple pressure boiler

●ST Machine configuration : ALSTOM make of 140MW

PreviousExperience:

●Working as Control Room Engineer for a combined cycle power plant at GentingLanco private India Limited of 742 MW from September 2015 to September 2017.

●Undergone GE9FA liquid fuel commissioning activities upto baseload

●GT Machine configuration : GE 9FA (Mark 6e control system)2xGT each of 240MW

●HRSG: Triple pressure boiler with HP reheating (Thermax Make)

●ST Machine configuration : Harbin Make 2xST each of 127MW

●Involved in combustion inspection and major overhaul inspections of a GE 9FA gas turbine.

●Undergone GE9FA liquid fuel commissioning upto baseload

Previous Experience:

●Worked as a Assistant Manager (control room operations) from June 15th 2015 to September 05th 2015

●Worked as a Assistant Manager (control room operations) for a combined cycle power plant at Segexoman India Private Limited (ONGC Tripura power) of 726.6MW.

●GT Machine configuration : GE 9FA (Mark 6e control system)

●HRSG: Triple pressure boiler with HP reheating

●ST Machine configuration : BHEL Make (MaxDNA control system)

Previous Experience:

●Around 5 years of comprehensive experience in the field of Power Plant Operations and performance activities in GVK Energy limited.

●Worked for a combined cycle power plant of 228 MW

●GT Machine configuration: ALSTOM-13E2 (150 MW) EGATROL 8.

●HRSG : Triple Pressure boiler (Alstom make)

●ST machine configuration : Alstom make (80MW) ALSPA 320

●Involved in HSD pre-commissioning activities as a field and control room engineer.

Achievements:

Worked as a IMS coordinator for operations

Active member in Root cause analysis Team.

Replaced the IDCT fans blade material with FRP to increase the performance.

Replaced the fire water system Jockey pump to energy efficiency pump.

Main Cooling Water pump internal parts have been coated with corro coating to increase the pump performance.

Replaced the continuous using lighting with LED lights to decrease auxiliary consumption.

Provided VFD for condensate extraction pump which decreases 50% of its power during single HRSG operation

Specializations:

●As a Active member from Association of Energy Engineers from Mercer University drive, Atlanta.

●Received a certificate of “Boiler Operating Engineer (BOE)”from Government of Andhra Pradesh Boilers Department.

●Received a certificate of "Energy Auditor" from Bureau of Energy Efficiency is an agency of Central Government of India.

Softwares Packages:

SAP and ENGICA

MS Office

GATE Cycle and EBSILON modelling and extracting the results

Power BI

Certifications:

Undergone certification for “Process safety Management” from NEBOSH

Undergone certification for “Incident Commander” from international college of Engineering and Management, Muscat.

Undergone certification for “Managing Safety” from IOSH

Undergone certification for “Fire Awareness Inducton” from international college of Engineering and Management, Muscat.

Educational background:

Pursed MBA in Power Management (78%) from University of Petroleum and Energy Studies,Dehradun.

●B.Tech in Mechanical Engineering. (73.5%), Godavari Institute Of Engineering and Technology (J.N.T.U) in April 2010.

●Diploma In Mechanical Engineering(75.5%),S.M.V.M Polytechnic (S.B.T.E.T) in April 2007

Key Highlights:

●Gas turbine 4x300 MW (Alstom 26)

●Gas turbine 2x130 MW (GE 9E,GE Make).

●Gas turbine 2 x 240 MW (GE9FA, GE Make).

●Gas turbine Alstom 13E2 (1x 150MW).

●Steam Turbine Alstom (2x302MW)

●Steam Turbine 125 MW (ALSTOM Make).

●Steam Turbine 2x127 MW, (Harbin Make).

●Steam Turbine Alstom (1x80MW)

●Relays, SF6, ACB, Vacuum Breakers .

●HRSG by Thermax and ALSTOM

●RO/DM plant.

●GIS and Open switch yard 400Kv operating system.

●MINIMAX Co2 System, Fire & Protection System,TOM CO2 system.

Personal Details:

Name : B.BALA KRISHNA REDDY

Date of Birth : 07/11/1986

Languages : English,Hindi,Telugu.

Address for Correspondence : BalaKrishnareddy

Dno:2-6-9

Antyakulavari street,

Alcott gardens,

Rajahmundry-533101

E-mail : adnl2b@r.postjobfree.com:adnl2b@r.postjobfree.com

adnl2b@r.postjobfree.com

Total experience in power plant : 11 years

Notice period : 15 days

Skype ID : bbkreddy007

Declaration:

With the above quoted experience in combined cycle power plant, I hope I would best suit to your requirement & if given a chance to prove myself. I hope you would consider my candidature and give me an opportunity to work in your esteemed organization. yours sincerely,

(B.Bala Krishna Reddy)



Contact this candidate