Post Job Free

Resume

Sign in

Electrical Engineer-Engineering,Protection&commissoning

Location:
Tirunelveli, Tamil Nadu, India
Salary:
12000
Posted:
July 01, 2021

Contact this candidate

Resume:

CURRICULUM VITAE

E-mail id: adng8s@r.postjobfree.com

Mobile No: +966-*********

+91-979*******

OBJECTIVE:

I can give my engineering, Project Management, Site management, Testing & Commissioning background. I can perfectly help for productivity and effectiveness of company. Beginning 2013 spanning over 8 years in EPC Projects, Transmission & Distribution, Power Plant, Substation and Oil & Gas projects. Utilize my skills and abilities to have a dynamic, challenging & rewarding career in an organization where I can have the opportunity to excel professionally. PROFILE:

A qualified Bachelor engineer with good knowledge and experience in electrical field, able to work on own initiative as a part of team. Having rich experience in Project Management and Site management for execution of Power Substation, Power plant, Distribution and Oil & Gas Projects. Having very good experience & knowledge in Testing and Commissioning of All Protection Relays/Main IED’s, Protection Panels scheme, Control Panels, Switchgear, LV Panels, Transformers, HV, MV and LV Cables for Substations (400,380,132, 33, 13.8 and 6.6 KV Levels). Operation and Maintenance of Electricity Distribution System, Testing and Maintenance of Automated Test Fixtures. PROFESSIONAL SKILLS:

Having extensive experience in project execution for successful completion of the project as per project contractual milestone

Ability to work in site execution for installation and testing and commissioning.

Experience in Testing and Commissioning of power system protection relays and control system.

Knowledge of SLD (Single Line Diagram), ANSI codes and symbols.

Design and Testing of Interlocking schemes, control and alarm schemes, OHL, Transformer and Breaker failure schemes.

Knowledge of operating the primary and secondary injection test kits like Omicron 256,Omicron 356,Doble F6150,Megger SMRT36,Punova,CPC 100,Winding Resistance Kit(SCOPE),Contact Resistance and Timing Meter(SCOPE), HV Test Kits and have some hands on experience on

Testing of Protection Functions like Distance protection, scheme communication protection, Line Differential protection, Transformer Differential protection (High Impedance/Low Impedance), REF protection etc.

Knowledge in trouble shooting of protection and control schemes as well as Functional and

Knowledge of configuring protection IED’s for Control/Alarms functions for the purpose of integrating with SAS systems and performing Local/close loop tests in co-ordination with SAS team.

Testing of CT”s, PT’s,Transducers, Multifunction meters, Energy Meters and all types of Digital Meters

EXPERIENCE DETAILS :( Starting from June 2013 till now) COMPANY: M/S WESCOSA LTD, KSA

Position Held :Sr.Electrical Engineer-Protection.

Duration: Since May 2018 to March 2021

Roles and Responsibilities:

Arrange and provide technical inputs to the Design Team, during the design phase of the project

Liaison with Client, Design Team and other stake holders of project to obtain approvals on design and NOC’s/permits during the construction.

Arranging delivery of all the equipment /materials at Project site as per base line schedule.

Arranging necessary resources (i.e.)/ sub-contractors, approved documents, drawings. Manpower, and tools/tackles at project sites.

Monitoring and supervising all site activities of the project and ensuring completion to budget and as per approved baseline time schedule.

Executing the projects according to the project plan

Monitoring the projects progress and making adjustments as necessary.

Coordinating with Testing & Commissioning Engineer for timely operation of Testing & Commissioning activity

Providing the solutions for the protection system and to enhance the support for the substation

control system.

Preparing the protection logic diagram & protection philosophy for the applicable bay along with

the interlock logics as per requirement.

Revising the scheme against client comments received from SEC/Consultants.

Preparing the Protection relay & BCU I/O list as per the application.

Review of protection relay setting calculation.

Adapting the setting calculation for the relays provided by Customer/Consultant.

Furnishing the test reports to the customer after completion of the testing & witnessing process.

Working in energized S/S during retrofit jobs without causing interruption to the system while

performing modification activities on existing schemes.

Testing of Relays,CT’s, PT’s,Transducers, Multifunction meters, Energy Meters and all types of

Digital Meters

Functional and Scheme testing of the Protection, Control and Switchgear panels.

Conducting High Voltage Tests for MV and LV Switchgear Panels, HV & MV Power Cables and

Switchgear equipment’s.

COMPANY: M/S SYNERGY POWER CO, KSA

Position Held : Electrical Engineer.

Duration: Since July 2016 to January 2018

Roles and Responsibilities:

Providing the solutions for the protection system and to enhance the support for the substation

control system.

Preparing the protection logic diagram & protection philosophy for the applicable bay along with

the interlock logics as per requirement.

Revising the scheme against client comments received from SEC/Consultants.

Preparing the Protection relay & BCU I/O list as per the application.

Review of protection relay setting calculation.

Adapting the setting calculation for the relays provided by Customer/Consultant.

Furnishing the test reports to the customer after completion of the testing & witnessing process.

Working in energized S/S during retrofit jobs without causing interruption to the system while

performing modification activities on existing schemes.

Testing of CT”s, PT’s,Transducers, Multifunction meters, Energy Meters and all types of Digital

Meters

Functional and Scheme testing of the Protection, Control and Switchgear panels.

Conducting High Voltage Tests for MV and LV Switchgear Panels, HV & MV Power Cables and

Switchgear equipment’s.

Co-ordinate and planning the testing activities with Customers (Witness) and planning the activities according to the schedules on a regular basis.

COMPANY: M/S ALFANAR CO, KSA (Short-term)

Position Held : Maintenance Engineer.

Duration: Since January 2016 to June 2016

Roles and Responsibilities:

Handling project activities involving working out various requirements with respect to utilities, manpower & monitoring overall project operations for ensuring timely completion.

Managing resources to perform project activities in cost effective manner.

Dealing with consultants/ licensors/ statutory bodies for compliance of requirements.

Ensuring proper inventory control on the spare parts and their replacement.

Identifying areas of obstruction/breakdowns and taking steps to solve the problems in an

effective manner.

Executing cost saving and energy saving techniques/ measures and modifications to achieve reduction in O&M expenditures and work within the budget.

COMPANY: M/S VOLTECH ENGINEERS PVT LTD

Position Held : Electrical Protection Engineer.

Duration: Since June 2013 to November 2015

Roles and Responsibilities:

Testing of Relays and Control Panels for various protection systems such as Line Protection, Feeder Protection, Motor Protection and Transformer Protection & Generator Protection.

Testing of Numerical and Electro-mechanical relays.

Able to read Single line Diagram and perform the testing of protection systems.

Schematic level testing of Relay and Control panels.

Incoming (QA/QC) Quality material inspection and testing.

Handling customer inspection and testing activities. TESTING AND CONFIGURATION OF RELAYS:

Testing and commissioning of following substation Protective and Control Relays. TYPE

MAKE

SKILLS

SEL 411L,311L,487Z,451,751A,710,

849.

SEL Configuration of relays using SEL

AcSELerator Quick SET Parameter

Tool.

RED670,REL670,RET670,RET615,

REF615,REF610,REF620,REF542

SPAJ140,SPAJ160,SPAU130,

SPAF140C

ABB

Configuration and Testing of ABB make

relays using Omicron Test Kits.

Configuration of relays using PCM 600 –

(Version 1.5,2.0, 2.2, 2.3,2.4,2.5 ).

7SD522,7UT612,7UT633,7UM622,

7SJ621,7SJ631,7SK802

SIEMENS Configuration of relays using DIGSI

Software

-(Version 4.81 to 4.93).

P546,P442, P443,P444,

P343,P220,P222,P243, P241,

P632,P633,P642,

P111,P123,P122,P127, P141,

P142,P143, P145, P545, P643,P921

ALSTOM/ Configuration of relays using Micom Studio, Agile software.

F650, D60, T60,MIV-II & MIV-II. GE Configuration of relays using F650,UR RELAY software.

T42, M42, S40&S42. SEPAM Configuration of relays using SFT2841 software.

-(Version 16.0).

List of Projects Completed: Saudi Arabia(OIL&GAS-ARAMCO) Project Name

Customer End Customer Nature of Job

Testing of 115KV

HV Protection

Panel& Relays for

115kV GIS

ARAMCO

substation at

DURMA,Saudi

Arabia.

M/S SEPCO M/S ARAMCO

Configuration and testing of all Bays

protective relays

( SEL 311L,L90,451,751A )

Functional Checks for all bays and LCC

panels.

Commissioning and energisation co-

ordination.

Testing of 115KV

HV Protection

Panel& Relays for

115kV GIS

ARAMCO

substation at

HOFUF, Saudi

Arabia.

M/S SEPCO M/S ARAMCO Configuration and testing of all Bays protective relays

( SEL 311L,L90,451,751A )

Functional Checks for all bays and LCC

panels.

Commissioning and energisation co-

ordination.

Testing of 115KV

HV Protection

Panel& Relays for

115kV GIS

EXPANSION CPF

ARAMCO

substation at

KHURAISH, Saudi

Arabia.

M/S SAIPEM. M/S ARAMCO Configuration and testing of two Bays protective relays (P546,L90,451,751A,710 )

Functional Checks for two bays and LCC

panels.

Commissioning and energisation co-

ordination.

Testing of MV GIS&

Protection Relays

for 33 kV GIS at

TASNEE

PETROCHEMICAL

PLANT at Jubail,

Saudi Arabia.

M/S TASNEE

LTD.

M/S TASNEE

LTD.

Configuration and testing of protective

relays (7SJ610,7SJ642&7SD610 relay )

Testing of CB,CT’S VT’S,busbar, Cable and

MFM meters.

Testing of

115/33/13.8kV

Switch gears &

Protection Relays

for JIGCC

REFINERY

PROJECT

substation at

Jazan, Saudi

Arabia.

M/S Tecnicas

Reunidas.

M/S ARAMCO Configuration and testing of all Bays

protective relays (SEL

311L,451,487Z,710&751A )

Functional Checks for all MV&LV Switch

gears.

Functional Checks for all MV&LV MCC’S

Commissioning and energisation co-

ordination.(3 substations)

Testing of

115/33/13.8kV

Switch gears &

Protection Relays

for JIGCC

REFINERY

PROJECT

M/S Tecnicas

Reunidas.

M/S ARAMCO Configuration and testing of all Bays

protective relays (SEL

311L,451,487Z,710&751A )

Functional Checks for all MV&LV Switch

gears.

Functional Checks for all MV&LV MCC’S

substation at

Jazan, Saudi

Arabia.

Commissioning and energisation co-

ordination.(3 substations)

Testing of MV

Switch Gear and

Protection Relays

for 13.8 kV and 33

kV substations at

ABU ALI ISLAND

at Abuali, Saudi

Arabia.

M/S AL-TOUKHI

COMPANY.

M/S ARAMCO Configuration and testing of protective relays (SIEMENS 7SD532&7SD532 cable

differential and GE relay )

Functional Checks for all switchgears.

Middle East - Saudi Arabia(SAUDI ELECTRICITY CO & PRIVATE UTILITIES) Project Name

Customer End

Customer

Nature of Job

Testing of 132kV HV

Protection Panel& Relays

for 8783 SEC substation

at Wadi al Dawasir,

Saudi Arabia.

M/S NOOR

COMMUNICATION

LTD.

M/S SEC Configuration and testing of protective

relays (RED670,RED615,REC670,P545 )

Functional Checks for two bays and LCC

panels.

Testing of Control panel

for 380/110/13.8 kV EHV

substation at SWCC

WATER PLANT at

Jeddha, Saudi Arabia.

M/S AL-TOUKHI

COMPANY.

M/S SEC Configuration and testing of protective

relays(REF615 ABB feeder protection

relay)

Testing of auxiliary relays

(RXMS1,RXSF,RXMD,RXKL,etc).

Testing of CT testing and loop check.

Testing of metrosils,

MCB’S,Contactors&Timers.

Scheme check for switch gear.

Testing of Control panel

for 110/13.8 kV

substation at JEDDHA

NEW PORT at Jeddha,

Saudi Arabia.

M/S NESMA

ELECTRIC

COMPANY.

M/S SEC Configuration and testing of protective

relays

(P141 ALSTOM feeder protection relay)

Testing of auxiliary relays (MVAX,

MVAJ,RXMS1,RXSF1,RXKL,etc).

Testing of CT,VT& VCB.

Scheme check for switch gear

Testing of MV and LV

Switch Gear Protection

Relays for 4.16 and 13.8

kV substation at Al

Qassim Central Power

plant at Qassim, Saudi

Arabia.

M/S NCC CO. M/S SEC Configuration and testing of protective relays (argus 7S110 feeder relay )

Testing of VCB, VT’S,busbar, Cable and

MFM meters.

Testing of MV Switch

Gear Protection Relays

for 13.8 kV Switch gear

at 8055 SEC

substation at Riyadh.

M/S Siemens. M/S SEC Testing of protective relays (MCGG11 ALSTOM feeder protection relay).

Testing of VCB.

Erection and Testing of

MV Switch Gear and

Protection Relays for

13.8 kV Switch gear at at

SAGO at Jizan, Saudi

Arabia.

M/S Schneider

Electric.

M/S SAGO Configuration and testing of protective

relays (T40 Sepam feeder relay )

Testing of VCB, VT’S,busbar, Cable and

MFM meters.

Erection and Testing of

MV Switch Gear and

Protection Relays for

13.8 kV and 33 kV

Substation at Almarai

milk farm at Alkharj.

M/S Schneider

Electric.

M/S ALMARAI Configuration and testing of protective relays (P546&T40 Sepam feeder relay )

Testing of VCB and MFM meters.

Functional Checks for all switchgears.

Testing of 13.8 kV

Capacitor bank for

115/13.8kV

Mardumah(ROYAL

COMMISSION)

substation at Jubail,

Saudi Arabia.

M/S Hadi Haider

Co

M/S ROYAL

COMMISSION

Erection & inspection of capacitor bank.

Testing of capacitors, reactors and

NCT’s (5 units)

Testing of MV Switch

Gear Protection Relays

for 4.16 kV substation at

KAPSARC at Riyadh, Saudi

Arabia.

M/S

ELSIEF(ARAMCO)

CO LTD.

M/S KAPSARC Configuration and testing of protective relays (T40,M42&MLJ SYNCH feeder relay)

Testing Cable and MFM meters.

Testing of 13.8 kV

Capacitor bank for New

33/13.8 kV skaka

industrial substation at

Al-Jouf, Saudi Arabia.

M/S TAQQAT

GLOBAL CO LTD

(ALHAITAM).

M/S SEC Erection & inspection of capacitor bank.

Testing of capacitors, reactors and

NCT’s (2units)

Testing of 33 kV

Transformers in Almarai

at milk farm at Alkharj,

Saudi Arabia.

M/S Schneider

Electric.

M/S ALMARAI Testing of Two Power transformers(AMC). Testing of MV Switch

Gear Protection Relays

for 13.8 kV Switch gear

at 8055 SEC

substation at Riyadh.

SAUDI BUILDING

MAINTANANCE

CO LIMITED.

M/S SEC Configuration and testing of protective

relays (7SK Siemens feeder protection

relay)

Testing of VCB, Transformer and Cable.

Project Name

Customer End Customer Nature of Job

Testing of MV Switch Gear

Protection Relays for 13.8 kV

substations at PRINCES

NOORAH UNIVERSITY at Riyadh.

M/S SAFARI

CO LTD.

M/S PNU

UNIVERSITY Configuration and testing of

protective relays (T40 Sepam

feeder relay )

Testing of VCB,

Transformer,busbar, Cable and

MFM meters.

Testing of MV Switch Gear

Protection Relays for 13.8 kV

substations at MILITARY OF

INTELLIGENCE CAMPUS at

Riyadh, Saudi Arabia.

M/S AN-

NASBAN

GROUP.

M/S MIC Configuration and testing of

protective relays (REF615 ABB &T40

Sepam feeder relay ) Testing of

VCB,Transformer,Cable and MFM

meters.

Testing of LV Switch Gear

Protection Relays for

Distribution substation at

Saudi Arabian Monetary

Authority at Riyadh, Saudi

Arabia.

M/S SAMA

(GOV).

M/S SAMA Configuration and testing of

protective relays (P142 Schnider

&T41 Sepam feeder relay )

Testing of ACB,Transformer and

MFM meters.

Across - India

Project Name

Customer End Customer Nature of Job

Testing & Pre

commissioning of MV

Switch Gear Protection

Relays for 66/11 kV

Substation in CAIRN

OIL&GAS PLANT at

Barmer,Rajasthan.

M/S CAIRN

ENERGY

LTD.

M/S CAIRN Configuration and testing of protective

relays (P442,141,REF615,RET642)

Testing & Pre

commissioning of HV

Control panels & Protection

Relays @ 132/33 kV

Substation in TPCIL

THERMAL POWER PLANT

at Nellore,Andhra Pradesh.

M/S BGR

ENERGY

SYSTEM

LTD.

M/S TPCIL Configuration and testing of protective

relays (P632,P442,P343,P127) in 2*660

MW Thermal Power Plant

Testing & Pre

commissioning of HV

Control panels & Protection

Relays @ 400/132 kV

Substation in

NAVABARATH THERMAL

POWER PLANT at

Pollanchi,Andhra Pradesh.

M/S NAVA

BHARAT

VENTURES

LTD.

M/S NAVA Configuration and testing of protective

relays (REL650,P444,RET615) in 4*60 MW

Thermal Power Plant

Testing & Pre

commissioning of HV

Control panels & Protection

Relays @ 132/33 kV

M/S

SIEMENS.

M/S JK TY Configuration and testing of protective

relays (7SA61,7SJ80,7SR011) in

Substation in JK TYRES

LIMITED at

Sriperampudur,Chennai.

132/33kV substation at JK TYRES

LIMITED.

Testing & Pre

commissioning of HV

Control panels & Protection

Relays @ 132/11 kV

Substation in ADITHYA

BIRLA UTKAL ALUMINA

PLANT at Dikri,Orissa.

M/S ABB. M/S ADITHYA Configuration and testing of protective relays (REM545,RET670,7UM522,7SJ80)

in 3*60 MW Capitive Power Plant

Testing & Pre

commissioning of HV

Control panels & Protection

Relays @ 132/11kV

Substation in 30 MW

SOLAR POWER PLANT at

Raipur,Chattisgarh.

M/S AMTEK

INDIA LTD.

M/S HARTEK Configuration and testing of protective relays (P442,P643,P142) in 30 MW Solar

Power Plant

Testing & Pre

commissioning of MV Switch

Gear Protection Relays @

132/33 kV at CHUZACHEN

HYDRO ELECTRIC

PROJECT at East,Sikkim.

M/S GATI

INFRA PVT

LTD.

M/S CHDP Configuration and testing of protective

relays (P741,P921,P141) in 2*55 MW

Hydro Power Plant

Testing & Pre

commissioning of HV

Control panels & Protection

Relays @ 132/33 kV

Substation in GSPC ltd,at

Yanam,Pudhucherrey.

M/S GE

POWER LTD.

M/S GSPC Configuration and testing of protective

relays (F750,MIV-2,MIF-2) in 132/33 kV

Chndel Substation at GUJRATH STATE

PETROLUM CORPORATION.

Testing & Pre

commissioning of HV

Control panels & Protection

Relays @ 132/33 kV

Substation in TATA STEELS

LTD at Jarjpur,Orissa.

M/S VOLTAS

LTD.

M/S TATA

STEELS

Configuration and testing of protective

relays (P632,P141,P127,P122) in

132/33kV Substation at TATA STEELS

INDIA LTD.

Testing & Pre

commissioning of HV

Control panels & Protection

Relays @ 132/33 kV

Substation in TECNO PARK

at Kollam,Kerala.

M/S

SIEMENS.

M/S KSEB Configuration and testing of protective

relays (7SK804,7SK802,7SJ803.7SJ802,

7SJ622,REF615,REM615,P141,P143,P241)

at INDIAN OIL CORPORATION LTD.

Testing & Pre

commissioning of HV

Control panels & Protection

Relays @ 6.6kV&11kV

Substation in IOCL at

Paradeep,Orissa.

M/S

ROHINI.

M/S IOCL Configuration and testing of protective

relays (REM545,RET670,7UM522,7SJ80)

in 3*60 MW Captive Power Plant

Testing & Pre

commissioning of MV Switch

Gear Protection Relays @

132/11 kV at TATA STEELS

LTD at Orissa.

M/S

FLAKTWOOD

LTD.

M/S TATA

STEELS

Configuration and testing of protective

relays (REF615,REM615,RET670) in

33/11 kV Substation at ZF Plant Ltd

Academic Performance:

Examination Passed Institution Year of Passing % of Marks Professional Qualification:

B.E in Electronic &

Electronics Engineering

Diploma in Electrical and

Electronics Engineering

MBA in Project

Management

Anna University,

TamilNadu,India

St.Xaviers Polytechnic

College.

Allagapa University,

Tamil Nadu By Distance

Education Mode.

April 2013

April 2010

December 2016

65%

68%

65%

Trainings Details:

Undergone one week training on Transformer Manufacturing and Testing in Alfanar

transformer factory.

Undergone one Month training on Numerical Relays Testing in VTC -CHENNAI

The training covered all the numerical relay makes: ABB, SIEMENS and ARIVA. Achievements:

I got an appreciation letter from the customer (TECNICAS RENUIDAS) by last year for successful completion of project on time for testing and commissioning of 3 NO’s substations in JIGCC ARAMCO REFINARY PROJECT.

Personal Profile:

Father's Name : M.Kaja Mydeen

Permanent Address : 54, PKP North Street, Melapalayam.Tirunelveli-627005, Tamil Nadu, India, Pho: 0091-9791868735,

Language Known : English, Hindi,Tamil, and Malayalam. Passport No : R 8929030 (Expiry Date: 14-02-2028). Driving License : Having SAUDI ARABIA Driving License DECLARATION:

I hereby declare that all the information furnished above is true to the best of my knowledge. Date : 22-06-2020 (K.Mohideen Gnaniyar)



Contact this candidate