Post Job Free

Resume

Sign in

l Hvac Engineer

Location:
Ramanathapuram, Tamil Nadu, India
Salary:
INR 32500 /Month
Posted:
August 04, 2021

Contact this candidate

Resume:

Curriculum Vitae

RAJA.E,

HVAC ENGINEER (DESIGN &SITE)

Mobile: +91-996*******

adn1jj@r.postjobfree.com

OBJECTIVES:

I have 7.5 years’ experience as a Mechanical Engineer in HVAC systems, searching a challenging position in Mechanical services with your esteemed company where I can apply my experience in your projects that will help me to translate my skills acquisition into skill application to contribute to the company’s success as well as to my personal career advancement.

EDUCATIONAL PROFILE:

S.NO

QUALIFICATION

COLLEGE /SCHOOL

YEAR OF PASSING

PERCENTAGE %

1

BE (Mechanical engineering)

P.T.R.College of engg&tech, Madurai.

2008-2012

7.70 GCPA

2

HSC

St. Josephs Hr Sec School, Muthupettai, Ramanathapuram.

2007-2008

76.83%

3

SSLC

Govt Hr Sec School, Regunathapuram, Ramanathapuram.

2005-2006

77.80%

ROLE & RESPONSIBLITIES:

Studying HVAC shop drawing and civil layout.

Material Take off Complete HVAC systems as per Drawings and Site Condition.

Allocate The Works to supervisor and team leader.

Chilled water Pipe installation as per shop drawing and site condition.

Duct Installation as per shop drawings and site condition.

AHU&FCU Installation with Valve Packages.

Chilled water pump installation with valve Packages.

Smoke Exhaust and Tunnel Exhaust Fan Installation.

Solve Site co-ordination issues with other services. Complete the given task in committed duration.

Arrange the consultant inspection for the installed air conditioning equipment’s, accessories and getting approval.

Attending Co-ordination Meeting.

Arrange the required material to complete the work.

Making as built drawing after the consultant approval.

Create the awareness about safety by conducting safety tool box talk.

Conducting duct air leakage test.

Conducting Chilled Water Pipe Leakage test.

Co-ordinate with commissioning team.

Check the sub-contractor measurement Sheets in as per site condition.

Check the Sub contractor billing for as Purchase order (PO) &Work order (WO).

Preparing DBR (Design basis report), Datasheet (DS), Technical Specification (TS), BOQ (Bill of Quantity) and MTO (Material Take off) according to design.

TECHNICAL SKILLS

Heat load Calculation using by HAP 4.31& Excel Software’s.

Ducting and pipe design using Mc Quay Software.

Air component size calculation.

Ability to design and drafting using Auto CAD.

MS OFFICE (Word, Excel,).

Ventilation system design using ACH Method (Toilet, kitchen, Transformer Room,DG Room,HT&LT Panel Room,Pump Room, Boiler Room Air Supply & Car parking Ventilation System etc.,)

Head Calculation for pump by using Darcy-Weisbach Equation.

Coordination of drawing with other services and prepares a working drawing as per site condition.

WORK EXPERIENCE:

Company : Aero Engineering,

Designation : HVAC Engineer-(Design & Site),

Duration : 24-Sep-2012 to 22-Feb-2020.

LIST OF PROJECTS DESIGN & HANDLE IN AERO ENGINEERING CHENNAI:

Project name : Anandha vikadan admin office (Plant Room Only)-Mount Road, Chennai,

Total Capacity : 300 TR-water cooled Chilled Water System,

Client : Vikadan Publishers Pvt Ltd.

Project name : Raja Muthaiah Mandram -Madurai,

Total Capacity : 161 TR-Air cooled DX System,

Client : Tamilesai Sangam.

Project name : Big Bazaar-Ampa skywalk Mall –Chennai,

Total Capacity : 208 TR-Air cooled DX System (CSU and Chilled water pipe installation only),

Client : Ampa Housing Pvt Ltd.

Project name : Aura Cinemas @Ascendas Park square Mall-Bangalore,

Total Capacity : 160 TR-Direct Return Chilled Water System,

Client : SPI Cinemas.

Project name : S2 Cinemas @Noma Flex-Hyderabad,

Total Capacity : 186 TR-Air Cooled DX systems,

Client : SPI Cinemas.

Project name : The Cinemas @Preston Mall-Hyderabad

Total Capacity : 214 TR-Air Cooled DX systems,

Client : SPI Cinemas.

Project name : Sangamitra Convention center-Puduchery,

Total Capacity : 286 TR-Air Cooled DX systems,

Client : Jayaram Marriage hall.

Project name : Vetri Cinemas-Madurai,

Total Capacity : 198 TR-Air Cooled DX systems,

Client : IVLR Developers.

Project name : The Cinemas @Providence Mall- Puduchery,

Total Capacity : 230 TR-Reverse return Chilled Water System,

Client : SPI Cinemas.

Project name : Sri Sakthi Cinemas-Trippur,

Total Capacity : 215 TR- Air cooled DX system,

Client : Sri Sakthi Cinemas.

Project name : Zeon Cinemas-Gopichettypalayam,

Total Capacity : 70 TR- Air cooled DX system & Air washer system,

Client : Zeon Cinemas.

Project name : Arul Jothi marriage hall -Ambatur,

Total Capacity : 100TR- Air cooled DX system,

Client : Arul jothi marriage developers.

Project name : Devi Marriage Hall -Chrompet,

Total Capacity : 97 TR- Air cooled DX System,

Client : Devi marriage Hall developers.

Project name : LUXE Cinemas, Phoenix market city-Vellachery,

Total Capacity : 430TR- Direct Return Chilled water system,

Client : SPI Cinemas.

PERSONAL DETAILS:

Place of Birth : India,

Date of Birth : 20.Apirl.1991,

Sex : Male,

Nationality : Indian,

Passport Number : L9297962,

Skype ID : rajaerulandi,

Marital status : Married,

DECLARATION:

I declare that all the information provided above is true to the best of my knowledge and belief.

Date: Yours Faithfully

Place: Chennai (RAJA.E)



Contact this candidate