Post Job Free

Resume

Sign in

Stationary Engineer

Location:
Arlington Heights, IL
Salary:
union wage
Posted:
May 29, 2021

Contact this candidate

Resume:

MATTHEW G. MCALEER

*** *. ******** ***

Arlington Heights, IL. 60005

adms0c@r.postjobfree.com

773-***-****

Experience:

*-****–-5/2021 CBRE: AT&T Bldg. Englewood Co.

Mobile Engineer…..servicing AT&T buildings in Colorado and Wyoming

Perform assigned day to day repairs and preventative maintenance. 8/19—1/2020 Cushman & Wakefield Rotary Bldg. Evanston, IL

• 347,556 sq. ft

• Trane chiller 520 tons

• BAS- building automation systems Trane

• CAT generator

• Voltage Familiar with 24v, 120v, 208v, 240v

4/2015---8/2019 Murphy Elementary School Chicago, IL

• 85,287 sq. ft.

• Boiler Kewanee-Scotch Marine-steam Low Pressure boiler 150 HP Air rHandling Unit- Built Up- Multi Zone- Dual Temperature Coils - Greater than 35000 cfm

• Johnson Pneumatic Controls

• Voltage Familiar with 24v, 120v, 208v, 240v

4/2013---4/2015 Schurz High School Chicago, IL

455,800 sq. ft.

• Hurst fire Tube boilers- 500 horsepower Max working pressure 15lbs

• Heat surface – 2500

• Air Handling Unit- Built Up- Multi Zone- Dual Temperature Coils - Greater than 35000 cfm

• Air Handling Unit- Built Up- Multi Zone- Dual Temperature Coils - Greater than 35000 cfm

• Air Handling Unit- Built Up- Multi Zone- Dual Temperature Coils - Greater than 35000 cfm

• Air Handling Unit- Built Up- Single Zone- Dual Temperature Coils - Greater than 35000 cfm

• Air Handling Unit- Built Up- Single Zone w/ Air Tunnel- Dual Temperature Coils - Greater than 35000 cfm

• Air Handling Unit- Built Up- Single Zone- Dual Temperature Coils - Greater than 35000 cfm

• Air Handling Unit- Built Up- Single Zone w/ Air Tunnel- Dual Temperature Coils - Greater than 35000 cfm

• McQuay chillers, 365 tons, refrigerant 134A

• Voltage Familiar with 24v, 120v, 208v, 240v

• BAS Automated Logic

• Pool 65,000 gallons

11/2010---3/2011 Chase Elementary School

• 84,715 sq. ft.

• Air Handling Unit 35000 cfm

• Centrifugal chiller -200 tons

• Boiler Scotch Marine- Hot Water Boiler - 2000 hp

• Pneumatic System controls Johnson Controls. Johnson Controls Thermostats -

• Voltage Familiar with 24v, 120v, 208v, 240v

3/2011---4/2013 Lafayette Elementary/Chi Arts

• 175,000 sq. ft.

• Boiler Auxiliary- Scotch Marine- Steam Low Pressure Boiler - 151 - 200 HP Boiler Auxiliary- Scotch Marine- Steam Low Pressure Boiler - 300 Hp

• Voltage Familiar with 24v, 120v, 208v, 240v

Barry Elementary School July 2010- November 2010

• 92,467 sq. ft.

• Scotch Marine- Steam Low Pressure Boiler - 200 HP

• Air Handling Unit 1- Built Up- Single Zone w/ Air Tunnel- Steam Coils 25000 cfm

• Air Handling Unit 2- Package Single Zone- Indoor- Steam Coils - 8000 cfm

• Voltage Familiar with 24v, 120v, 208v, 240v

• Johnson Pneumatic Controls

Certification:

-City of Chicago Stationary Engineer

-License EPA CFC Universal

-Certification Illinois Pool Operator -

Certification OSHA -10-hour

certification Online hand tools & -

Fasteners

-Electronic Damper Actuator

-Troubleshooting Industrial Maintenance

-Belts and Pulleys system

Education:

Triton College: Facilities Engineering Technology Certificate Pursuing an associate’s degree in Facilities Engineering Technology Indoor Air Quality Commercial Heating and cooling systems 1 Commercial Heating and cooling systems 2 Electrical Facilities for Engineers 1 Electrical Facilities for Engineers 2 Pneumatic & direct digital controls Basic Boiler Operations Plumbing Repair and Maintenance Critical Systems Chief Engineer (currently enrolled) Testing and Balancing (currently enrolled)

High School:

Notre Dame High School,

References:

Linda Liflar: CBRE 720-***-****

Bill Goebig Chief Engineer Schurz High School 773-***-**** William Iacullo Chief Engineer - Lincoln Park High School 773-***-****



Contact this candidate