PROFESSIONAL SUMMARY
Diligent individual capable of overseeing work quality with a bachelor’s degree and experience of maintenance and operation in different industrial plants. Worked in multiple projects and upgraded existing electrical systems according to requirements. WORK EXPERIENCE
Electrical Technician Jan 2017 - Present
Pal Cooling Holdings • Abu Dhabi
• Complete installation, testing, commissioning of PV modules, string arrays, module structure, inverter, ac and dc cabling
• Installed and tested new super capacitor batteries as a test model for upcoming project to check its efficiency and credibility
• Execution, testing, and commissioning of AC and DC earthing systems complete in all aspects
• Complete cable laying, cable termination, and cable glanding (power and control) meeting all standards and according to drawings on motors, motor starting panels, MDB’s, SMDB’s, and DB’s
• Installation of Cable tray, cable trunking, and cable ladder work complete in all respects
• Executed all electrical components with respect to drawings which comprises of lighting layout, power layout, grounding layout etc
• Preventive maintenance in MV and LV soft starters including different tests i.e Power quality test, Contact resistance testing, IR test, resistance checking and meggering of SCR’s
• Testing of motors, H.V cables, LV and MV circuit breakers, and high rating cables (IR test, PI test, vlf test)
• Installation, testing and commissioning of gas monitoring system
• Installation, designing of MDB’s, SMDB’s, and DB’s as per the load schedule
• Installation of MCB’s, MCCB’s, ELCB’s, RCCB’s, ACB’s, and Isolators etc
• Ensure proper maintenance of industrial equipment and modifications required for cost saving mechanism
• Preparation of Load scheduling and single line diagrams according to consumer’s requirements
• Installation testing and commissioning of actuators (single phase + three phase) and damper actuators
• Installation, calibration and commissioning of control instruments i.e temperature sensors and temperature transmitters, flow sensors and flow transmitters, pressure switches and pressure transmitters, level sensors and level transmitters
• Installation and calibration of ultrasonic flow sensors, magnetic flow sensors, humidity sensor, temperature sensor
• Coordinated and executed all fire alarm and fire fighting preventice maintenance including testing of FM200 system, smoke sensors, heat sensors, and fire fighting cylinders
• Scheduling and implementation of preventive maintenance plans of all industrial equipments
• Supervise multiple teams at a time to achieve target on a given duration. Electrical Trainee Sep 2015 - Nov 2016
Nishat DG Cement Company Limited • DG Khan
• Cable laying and conduiting for plant lighting system
• Installation, executing, and testing of coal plant earthing system
• Installed MCC’s, capacitor banks, bus bars and cabling for LV system according to drawings
• Installation, testing, and commissioning of motor starting panels
• Responsible for HV, LV, and control cable laying and termination of motors, sensors, and panels
• Installation of DBs, SMDBs, MDBs, control panel, power panel, cable tray routes, cable tray trenches, and pathways
EDUCATION
Bachelor’s of Science in Electrical Engineering Sep 2011 - Jun 2015 University of Central Punjab • Lahore
• Certified engineer from Pakistan Engineering Council
• Degree certified from United Arab Emirates, Higher Education Council, Pakistan Engineering Council, and Ministry of Foreign Affairs
SKILLS
• MATLAB, AUTOCAD, C++, Labview
• ORACLE (Enterprise Asset Management)
• Microsoft Office
• ETAP
• Project management, Time management skills and ability to work in tight deadlines
• Highly Responsible, Problem Solving Skills, Flexible and Reliable
• Result oriented with creative thinking ability and quick learner
• Team player with Leadership qualities, Able to follow direction as well as take initiative