Post Job Free

Resume

Sign in

Engineer Design

Location:
Vellore, Tamil Nadu, India
Posted:
March 08, 2021

Contact this candidate

Resume:

*

MAGESHWARAN L

TESTING ENGINEER

Mobile: +91-950*******

Email:

adkq0i@r.postjobfree.com

PERSONAL DATA

DATE OF BIRTH : 02/06/1996

NATIONALITY : INDIAN

MARITAL STATUS: SINGLE

PASSPORT NO : P1349927

LANGUAGES : ENGLISH, TAMIL,

AND HINDI

PERMANENT ADDRESS

S/O Loganathan.A

11A,1st Sengunther street,kaspa-a,

Ambur,vellore dist-635802

Tamilnadu.

CAREER OBJECTIVE

An Electrical Testing Engineer with aspiration to work and grow in all fields with eagerness, to accept challenges and contributes through my knowledge, skill and personal commitment for excellence and individual satisfaction and as a Team Player in multinational work force.

ACADAEMIC QALIFICATION

1. DIPLOMA.in Electrical and Electronics Engineering (2011-2014) from KAR Polytechnic College, Ambur (Secured 8.6% CGPA).

2. SSLC in Hindu higher secondary school,Ambur. (Percentage 80.6%). CAREER GROWTH

M/s.NEYVELI LIGNITE CORPORATION(NLC).

APPRENTERSHIP TRAINEE Feb2015 to feb 2016(1 year)

M/s. INEL POWER SYSTEM ENGINEERS (P) Ltd (Goa).

TESTING ENGINEER from Jul 2016 to Oct 2020(4 years&3 months). SKILL HIGHLIGHTS

Skilled to check various schemes of relay and control panels for all types of bus system from 6.6 kV to 765 kV.

Skilled to check all types of schemes and testing of switchgear panels.

Can able to prepare scheme for various protections using single line diagram

Can coordinate with design engineer regarding design issue and can able to correct the schemes

Skilled in all types of scheme checking such us Transformer Protection, Generator Protection, Motor Protection, Interlocks and other control circuit schemes with various systems.

Skilled to test various Numerical relays specially Siemens Relays having protection such as Differential Protection, Bus Bar.

Differential, Distance Protection, Earth fault & Over current Protection Trip circuit Supervision, Under Voltage & Over voltage Protection.

CT&PT Secondary Injection test using OMICRON and DOBLE Kit.

Liaised with client for As-Built scheme and test report submission.

Possess excellent interpersonal, leadership and managerial skills, commercially aware and capable of working well under pressure within a team.

PROFESSIONAL SUMMARY

Numerical IED Configuration and Testing

Hands on Experience:

Line Distance Protection

Line Differential protection

Generator Differential protection

Transformer Differential protection

Bus Bar Protection along with all basic Feeders& Motor protection

Scheme Checking, troubleshooting of Relay & Control panels

Configuration and testing of IEC61850 Signals for SCADA Applications.

Lead Engineer & Site coordination activities

RESPONSIBILITIES

Testing of SIEMENS, SCHNEIDER & ALSTOM relays using OMICRON UNIVERSE Test Kit.

DC logic Testing of Control and Relay panels ranging from 11kV to 765 kV.

Troubleshooting of Control and Protection Schemes.

HV Test for CB, Bus bar and Control & Relay Panel Wiring Circuits.

(QC) Testing of Control & Relay panels.

Co- ordination with Customers and Witness Testing of Control & Relay panels(FAT).

Protection scheme check with inter-locks and inter-trips. 2

NUMERICAL RELAY TESTING EXPERIENCE

SIEMENS MAKE RELAYS

6MD622 Bay-Control Unit and its all types of series

7UM61 & 7UM62 Generator Protection relay and its all types of series

7SA522, 7SA61. 7SA63 & 7SA64 Distance protection relay and its all types of series.

7UT612, 7UT613. 7UT63 Transformer protection relay and its all types of series.

7SD522 Line Differential Relay and its all types of series.

7SK80, 7SK81 Motor Protection relay and its all types of series.

7SJ80, 7SJ81, 7SJ61, Over current and feeder protection relay and its all types of series.

7RW80 & 7RW60 Voltage and frequency protection relay and its all types of series.

7SR224, 7SR242, 7SR210, 7SR220, 7SR11 & 7SR12 ARGUS relay and its all types of series.

7VK61 Breaker failure and auto reclosure relay

7SS52 Busbar protection panels

ALSTOM MAKE RELAYS

MICOM P40 Agile Overcurrent Protection relays.

MICOM P441, P443, P444 Line Protection relays.

MICOM P64X Trafo differential Protection relays.

MICOM P54X Line differential &Distance Protection relays.

SCHNEIDER MAKE RELAYS

MICOMP441,P443,P444 Line Protection relays.

MICOM P64X Trafo differential Protection relays.

MICOM P54X Line differential &Distance Protection relays. SOFTWARE HANDLED

DIGSI 4 v4.93 (SIEMENS)

DIGSI 5 v7.8 (SIEMENS)

REYDISP EVOLUTION (REYROLLE SIEMENS)

PCM 600 V2.8(ABB)

MICOM S1 AGLIE V1.3 (ALSTOM)

EASERGY STUDIO V7.1 (SCHNEIDER)

TEST UNIVERSE V4.0 (OMICROM CMC353,356,256 plus,253)

DOBLE (6150e)

IEC BROWSER

PROJECT HANDLED

1. PGCIL-GAYA EXTENSION, TUMKUR, MAPUSA, GOOTY.

Conducting FAT in Siemens Factory for testing of Transformer Differential Protection relay (Siemens-7UT613), Directional Over current relays (Siemens-7SJ804), Local Breaker Backup protection relay (Siemens-7VK61). Testing of control and relay panel as per the scheme.

2. TATA POWER 132/33kV KURLA END SUBSTATION.

Conducting FAT and Testing and configuration of numerical Line Distance Relay (Siemens-7SA522) (Alstom P444) and Bay Control unit (Siemens-6MD86), Transformer Differential Protection relay (Siemens-7UT63),Busbar Differential Protection(7SS85). Design correction in schemes as per the requirements of yard condition. 3. KPTCL 220/66kV KORAMANGALA SUBSTATION.

Conducting FAT and Testing and configuration of numerical Line Distance Relay (Siemens-7SA522) (Alstom P444) and Bay Control unit (Siemens-6MD86), Transformer Differential Protection relay (Siemens-7UT63). Design correction in schemes as per the requirements of yard condition.

4. APTRANSCO_JAMMALAMADUGU 400/220kV SUBSTATION.

Testing and configuration of numerical Line Distance Relay (Siemens-7SA522) (Alstom P444) and Bay Control unit

(Siemens-6MD66), Transformer Differential Protection relay (Siemens-7UT63) Relays. 5. TORRENT POWER 132 kV THALTEJ SUBSTATION.

Conducting FAT and Testing and configuration of numerical Line Distance Relay (Siemens-7SA522) (Alstom P444) and Bay Control unit (Siemens-6MD86), Transformer Differential Protection relay (Siemens-7UT63),Busbar Differential Protection(7SS85),Line Differential Protection Relay(7SD52). 6. PGCIL KALA 400/220kV GIS SUBSTATION.

Testing and configuration of numerical Line Distance Relay (Siemens-7SA522) (Alstom P444) and Bay Control unit

(Siemens-6MD86), Transformer Differential Protection relay (Siemens-7UT63) Relays. 7. NEPAL ELECTRICITY AUTHORITY 220/132kV UPPER TAMAKOSHI SUBSTATION. 3

Conducting FAT and Testing and configuration of numerical Line Distance Relay (Siemens-7SA522) (Schneider P444) and Bay Control unit (Siemens-6MD86), Transformer Differential Protection relay (Siemens-7UT63)(SchneiderP643),Busbar Differential Protection(7SS85).Checking Interlocks of CB,Isolaters,Earth switches. Design correction in schemes as per the requirements of yard condition.

TEST KIT HANDLED

OMICRON test kit.

DOBLE test kit

HV test kit.

Insulation Resistance tester.

CT, PT kit.

DECLARATION

I hereby declare that the details furnished above are true to the best of my knowledge. PLACE : Yours Truly,

DATE : MAGESHWARAN L



Contact this candidate