Post Job Free
Sign in

Maintenance Plant

Location:
Ramanathapuram, Tamil Nadu, India
Salary:
25000
Posted:
March 01, 2021

Contact this candidate

Resume:

Mobile: 995-***-****

Email : ****************@*****.***

RAJESH KUMAR.S

Career objective

To have a growth oriented and challenging career, where I can contribute my knowledge and skills to the organization and enhance my experience through continuous learning and teamwork. PROFILE

MECHANICAL & ELECTRICAL MAINTENANCE with Four years above of industrial experience. Adept in performing electrical installations, maintenance and repairs and plant facilities; knowledgeable in all areas of the national electrical code; and excel in analyzing and solving problems with various electrical controls and systems. Academic Qualification

Academic Project

MAIN PROJECT -- Automatic robot wall painting in horizontal and vertical movement

MINI PROJECT -- Mutiple nut remover and tighter

Course

University/

Board

Institute

Year of

passing

Percentage/

CGPA

B.E-

Mechanical

Engineering

Anna

University

Maharaja Prithvi

EngineeringCollege, Avinashi

2011-2015

6.75

(CGPA)

Higher

Secondary State Board

Syed Ammal Hr.Sec.School,

Ramanathapuram.

201*-****-**

SSLC

State Board

St.Josephs High School,

Ramanathapuram

2008-2009 86.7

PROFESSIONAL EXPERIENCE

1. Quess Corp(Hofincons) Pvt Ltd

SITE : Schneider Electric Poonamallee, Chennai

POSITION: MULTI SKILLED TECHNICIAN AUGUST 2015 T0 FEB 2018 Retained by Quess group to serve as a skilled electrician on Operation and maintenance works and implementing projects. Install new or upgrade existing systems and equipment at major manufacturing plants to achieve energy conservation goals. KEY RESULT

• Installed, maintained, repaired and tested equipment for the generation and utilization of electric energy for diverse-industry clients.

• Maintenance for Air compressor, Heat ventilation, Diesel generator, cctv camera .

• Air Compressor Atlas Copco up to 303 CFM Preventive and Breakdown Maintenance

• Power supply connection for machinery by calculating the machine load according to the requirement.

• Following the Daily check list for the utility critical equipment’s and MHE units. And reporting to the Superior if their any deviation in the Routine Activities

• 11KV yard DO fuse (100 and 125A rated) replacement incase of fuse blown out.

• Cable routing (Up to 25Sqmm) done for utility equipment’s according to the client requirement.

• Vendor Coordination for (AMC) breakdowns of equipment’s.

• Firefighting system monthly checked for fire hydrant, smoke detector, fire extinguisher, Manual call point, FM200 and installation for cctv camera.

• Daily A check for Air compressor & DG.

• To give power supply and pneumatic line for the machines in shop floor.

• Preparing weekly report and monthly MMR report of work submitted.

• Maintaining 5S in the work place.

• To Maintaining of Ro plant with the capacity of 750LPH & Stp with the capacity of 90KLD, Wtp plant with the capacity 9KL/HR

ABLE TO HANDLING MACHINE:

• Heat Ventilation and Air-conditioning up to (HVAC)-150TR Preventive and Breakdown Maintenance

• O&M of 11 KV substation with the allowed demand of 1750 KVA.

• Handle Breakers like SF6, VCB and ACB.

• Welding Chiller (W/C) – 100TR Preventive and Breakdown Maintenance

• UPS up to 200KVA Preventive and Breakdown Maintenance

• Air Compressor Atlas Copco up to 303 CFM Preventive and Breakdown Maintenance

• Kaeser compressor 550 CFM Preventive and Breakdown Maintenance

• Transformer upto 1250KVA Preventive and Breakdown Maintenance with OLTC.

• Diesel generator upto 1010KVA Preventive and Breakdown Maintenance

• Annual shutdown work planned and preventive maintenance.

• In machine side pneumatic line drop supply has been given. 2. COLDMAN LOGISTICS INDIA PVT LIMITED

POSITION : TECHNICAL SUPERVISIOR FEB 2018 TO FEB 2020 COLDMAN is one of the leading Supply Chain solution partners in the country, besides being India's market leader in cold supply chain and the only company with a pan-India network.

The comprehensive infrastructure covers end-to-end solutions from primary\ transportation, storage, inventory management and documentation to last mile retail distribution. The company offers complete and unique facilities for Temperature controlled Transportation/Storage, Handling and Retail Distribution of Frozen/Chilled Foods and also other dry goods handling

JOB RESPONSBILITIES:

• Maintained Refrigeration carrier make R-404a Plants and temperature range of

(-25.00 C)

• Can maintain Automated Doors, safety alarm systems, Hydraulic Dock systems, Battery operated Forklift, Racking systems.

• Having maintenance Knowledge on Double Deep Crown Make Reach Trucks.

• Maintenance knowledge in Air & Water cooled condensers, (Evaporative), Soprano, Evaparator coil

• Blast Freezer -40 Deg C, of 4 MT / Batch

• Expertise in servicing of hydraulic & pneumatic assets and varies assets like directional control valves, cylinders, Etc.

• Updating and maintaining the history card sheets for each machine.

• Can handle Pumps and assets in process maintenance.

• Maintenance of Water Softening Plants

• Updating and maintaining the ISO 9001 and 14001 related documents for maintenance department.

• Updating and maintaining the history card sheets for each machine.

• Maintenance of Utilities like DG, RO Plant, Refrigeration Plant (Ammonia), Air compressor, Drier, Softener Plant, Condensers, Cooling Towers Etc Operation and maintenance of below mentioned Equipment’s Equipment Name Make Capacity

HT yard 11kv

Transformer Areva 1250kva, 750kva and

500kva

DG Powerica 1010kva(2no’s) and 500kva

UPS APC and Numeric 100kva(3no’s),

60Kva,40Kva, 25kva and

10Kva

Air Compressor Atlas Copco & Kaeser 303CFM up to 7.5 psi(Max) and 550 CFM

Welding Chiller Reynold 100 TR

HVAC Dunham Bush 150TR

Maintenance of Material Handling Equipment(MHE) mentioned below Equipment

Name

Make Capacity Quantity

BT Reach Truck BT 2 ton 6nos

Stacker Maini, Vanjax 1 ton 4 nos

Ergomover BT 0.500 ton 4 nos

Fork lift Goorej 2 ton 3 nos

Dock leveller 9 ton 12nos

Achievements and Extra-curricular activities

• Sri Sathya Sai Disaster Management Team Faculty Member.

• I have participated in the seven days special camping on the theme HEALTHY YOUTH FOR HEALTHY INDIA organized at PUTHUPALAYAM.

• First Aid Trained By St.Jhon Ambulance,Tambaram.

• Active participant of NSS Special Camp and Active blood donor. Personal Profile

Date of Birth : 01.06.1993

Gender : Male

Marital status : Single

Current Salary : 22000 per month

Pass port no : N0238608

Pass port Expiry : 14.06.2025

Languages Known : Tamil, English (Read and Write)

Permanent Address S/O K.Sankaran,1/14,kozhi kottu street), Ramanathapuram (d.t)-623501

I hereby declare that all the details furnished here are true to the best of my knowledge. DATE : Your Sincerely

PLACE: (RAJESH KUMAR.S)



Contact this candidate