Post Job Free
Sign in

Power Plant Engineer

Location:
Bharathiyar Nagar, Tamil Nadu, India
Salary:
40000
Posted:
February 01, 2021

Contact this candidate

Resume:

RESUME

CAREER OBJECTIVE:

I AM LOOKING FOR A SUITABLE POSITION THAT WILL BUILD ON MY SKILLS

EDUCATIONAL QUALIFICATION:

.

EXAMINATION NAME OF INSTITUTION BOARD OF

STUDY

YEAR OF

COMPLETION

MARKS%

D.E.E.E. THATHI ROEVER INSTITUTE

OF POLYTECHNIC COLLEGE,

PERAMBALUR

DOTE 2008-2011 78.5

10TH GOVERNMENT HIGHER

SECONDARY SCHOOL, THENI

STATE

BOARD

200*-****-**

EXPERIENCE

6 Years Experience

B.HARIKUMAR

Email.id: ************@*****.***

PH: 097********

089********

DOOR NO:180,R.S THEATER OPPISTE,

BHARATHIYAR STREET,

SILLAMARTHAMPATTI,

THENI-625528.

CARER PROFILE

1. ORGANIZATION : SNIPE ENGINEERS PVT, LTD.

DESIGNATION : ELECTRICAL TESTING AND COMMISSIONING ENGINEER PERIOD : OCTOBER-2018 TO TILL DATE

2. ORGANIZATION : RESONANCES POWER SYSTEM PVT, LTD. DESIGNATION : ELECTRICAL TESTING AND COMMISSIONING ENGINEER PERIOD : JUNE-2016 TO MAY-2018

2. ORGANIZATION : SODEXO TECHNICAL SEVICES INDIA PVT, LTD. DESIGNATION : SUSBSTION O&M TECHNICIAN

PERIOD : AUGUST 2014 TO MAY-2016

DESIGNATION

ELECTRICAL TESTING AND COMMISSIONING ENGINEER

CONSERVANT IN

1. TESTING & COMMISSIONING OF ALL TYPES OF STATIC & NUMERICAL RELAYS.

2. NORMAL TESTING & COMMISSIONING OF INDUSTRIAL POWER PLANT, GAS PLANT.

3. CONFIGURATION OF ALL TYPES OF NUMERICAL RELAYS AS PER SCHEMATIC.

4. NORMAL TESTING AND COMMISSIONING OF LINE PROTECTION, CABLE DIFFERENTIAL.TESTING AND COMMISSIONING OF

TRANSFORMER & MOTOR PROTECTION, FEEDER MANAGEMENT

OVERCURRENT RELAYS.

5. HAVING KNOWLEDGE AND EXPERIENCE ON FOLLOWING

COMMISSIONING ACTIVITES

A) INTEGRATING THE TOTAL SUBSTATION WITH SCADA SYSTEM THROUGH GOOSEING WITH SIEMENS, MICOM AND ABB.

B) CO-ORDIANATED WITH CT & VT PRIMARY & SECONDARY

INJECTION.

C) FACTORY RELAY TESING HAS ALSO BEEN DONE.

6. HANDLED ELECTRICAL EQUIPMENT IN MAINTANANCE LIKE BREAKERS, POTENTIAL TRANSFORMERS & POWER TRANSFORMERS. THREE PHASE SECONDARY INJECTION KIT HANDLE

1. OMICRON

2. PONOVA

SOFTWARES HANDLED

1. SIEMENS - DIGSI 5,REYDISP MANANGER AND EVOLUATION 2. AREVA - MICOM 2.1, 3.1, 3.4.

NORMAL PRIMARY INJECTION KIT HANDLE

1. CT ANALYZER

2. PT ANALYZER

3. TRUN RATIO KIT

4. TAN-DELTA KIT

EXECUTED NORMAL WORKING INDUSTRIAL

SITE NAME : 110/11KV FORD INDIA PVT, LMT- CHENNAI

DESIGNATION : O&M TECHICIAN

TIME PERIOD : AUG 2014-MAY 2016

PROJECTS HANDLED

1. SITE NAME : 2*30MW TERMINAL POWERE PLANT- RAJASTHAN CLIENT : L&T

ACTIVITIES : TRANSFORMER,HT,LT PANELS,CABLES ARE TESTING AND COMMISSIONING.

TIME PERIOD : JUNE 2016 - FEB 2017

2. SITE NAME : 11KV/415V SWITCH GEAR SYSTEM-ORISSA CLIENT : IOCL

ACTIVITIES : TRANSFORMER,HT,LT PANELS,CABLES ARE TESTING AND COMMISSIONING.

TIME PERIOD : FEB 2017 - JUNE 2017

3. SITE NAME : 100MW SOLAR POWER PLANT-MAHARASTRA

CLIENT : L&T

ACTIVITIES : TRANSFORMER,HT,LT PANELS TESTING AND

COMMISSIONING

TIME PERIOD : JULY 2107- DEC 2017

4. EXECUTED TESTING OF THE FOLLOWING RELAYS JAY 2018 – MAY 2018.

SIEMENS MAKE : 7SR1206,72R1205 –O/C&E/F,U/O PROTECTION 7SR1706 – MOTOR PROTECTION

ALSTOM MAKE : P120,P122,P127,P141- O/C & E/F PROTECTION ABB MAKE: REL670-LINE PROTECTION RELAY

5. SITE NAME : 220/33KV SAIL STEEL PLANT- ORISSA

CLIENT : L&T

ACTIVITIES :RELAY,TRANSFORMER,HT,LTPANEL,MOTORS,CABLES ARE TESTING AND COMMISSIONING.

TIME PERIOD : OCT 2018- JUNE 2020

6. SITE NAME : RAJESWARI DEEP GAS TERMINAL- RAJASTHAN CLIENT : PETROFAC UNITED LIMITED

ACTIVITIES: RELAY,TRANSFORMER,DG,HT,LTPANEL,MOTORS,CABLES ARE TESTING AND COMMISSIONING.

TIME PERIOD : JULY 2020 - TILLNOW

DECLARATION:

I here by declare that all the details and particulars furnished above are correct to my knowledge. If opportunity is given, I will prove to be worthy of your confidence and satisfaction. Place: THENI

Date: B.HARIKUMAR



Contact this candidate