M.VELMURUGAN
Contact : 960*******
E-mail: adjoqy@r.postjobfree.com
adjoqy@r.postjobfree.com
Assignment in Operation and Maintenance / Project Management
Executive Summary
A Competent Professional with 29 years of experiences in Maintenance, Operations and Project Management
*Present Designations as Chief Engineer in M/s E – Hotel Unit of Express Infrastructure Pvt Ltd,Chennai, TamilNadu.
*Expertise in managing the operation & maintenance of facilities and installation of new system for maximum service efficiency.
*Proficient in trouble shooting & problem resolution; train and supervise technicians in quality, adherence to Works order specification and Equipment maintenance.
*Knowledge of handling any type and range of Generators, Power, Distribution, Current & Potential Transformers, HT & LT Panel, Protective Relays, Circuit Breakers, Power Cables, Power Consumption Meters, HVAC, UPS,Fire Protection System, BMS Operation, Schematic Diagrams.
*Exceptional team building organization and analytical skills coupled with demonstrated relationship management and communication abilities.
Areas of Expertise
Maintenance & Operations: Operation & Maintaining corrective & preventive maintenance for trouble free operations with maximum machine up time & efficiency: While curtailing the cost expanses. Handling maintenance of HT Diesel Generator, Oil & Dry Type Transformer, Current & potential Transformer, HT & LT Panel, AMF, PLC, Battery Banks, Protective Relays, Circuit Breakers, Power Cables, Power Consumption Meters, HAVC, Cooling Towers, Lighting Arrester. Investors, DBs,Starters, Fire Alarm & Detection System, Public address, Access Control, VVTV with monitoring DVR recording System.
Project Management: Handling Project Activities in Express Avenue Mall of M/s. Social Rest – o – Bar Project activities involving working out various requirements with respect to utilities, Equipment, Manpower & monitoring overall Project operation for ensuring timely completion.
Man Management: Assessing the training needs of the various employees in coordination with the various department heads in the respective departments.
Organization Experience
1. Sep 12th -2012 to Till Date M/s. E – Hotel EXPRESS INFRASTRUCTURE PVT LTD, has a CHIEF ENGINEER & EXECUTIVE HOUSE KEEPER
Handling Erection, Operation & Maintenance of Express Avenue Mall and E hotel & Residence:
• 33KV/433V Indoor Substation
• 2000 KVA Transformer – 6nos
• 2000 KVA Diesel Generator – 4 nos
• 1500 KVA Diesel Generator – 1 no
• 675 TR Screw Type Chiller - 4nos
• 225 TR Screw Type Chiller – 2nos
• 130 TR Screw Type Chiller – 2 nos
• Fire alarm and Sprinkler system
• 1000Kg/Hr Boiler – 2nos
• Maintained more than 2 lac Sq.ft
• Past 5 years additionally handled HOUSE KEEPING Dept has HOD
2. Jan 16 -2012 to Sep 11th 2012 M/S PARK PLAZA .Salem As CHIEF ENGINEER
Handling Erection, Operation & Maintenance of:
• 22 KV/433 V INDOOR Sub Station.
• 22 KV – 630 A HT VCB (VOLTAMP).
• 1000 KVA – 11 KV/433 Dry Type Transformers – 1 no.
• 600 KVA/415 V Diesel Generators – 2 Nos.
• ACB 2500A, 2000A, 1000A, 800A, 400A, 200A
• APFC – 600 KVA.
• BMS Automation System and Fire Alarm System.
• Centralized A/C Plant 225Tr – 2 No’s, AHUs and FCUs.
• PCC Panel, MCC Panels, MV Panel, PDB, LDB and Starters.
• BMS Automation system.
• Fire Alarm and Sprinkler System.
• 500Kg/h Boilers ( 3 No’s )And all Hotel Equipment.
3. July 02 -2010 to Jan 09 - 2012 with M/S Taj Madras Flight Kitchen PVT. LTD. Chennai (Unit of Taj Groups) as Engineer In-Charge
Handling Operation & Maintenance of:
• 11 KV/433 V INDOOR Sub Station.
• 11 KV – 630 A HT VCB (VOLTAMP).
• 630 KVA – 11 KV/433 Transformers – 2 nos.
• 500 KVA/415 V Diesel Generator
• ACB 1250A, 800A
• APFC – 800 KVA.
• BMS Automation System and Fire Alarm System.
• Centralized A/C Plant 100 TR – 3 No’s, AHUs and FCUs.
• PCC Panel, MCC Panels, MV Panel, PDB, LDB and Starters.
• BMS Automation system.
• Fire Alarm and Sprinkler System.
• 600Kg/h Boilers ( 3 No’s )And all Hotel Equipment.
4. July 02 -2008 to June 30 – 2010 with M/S The Rain Tree Hotel Chennai (Unit of Ceebros Hotels Pvt Ltd) as ASST ENGINEER
Handling Operation & Maintenance of:
• 11 KV/433 V INDOOR Sub Station.
• 11 KV – 630 A HT VCB (VOLTAMP).
• 750 KVA – 11 KV/433 Transformers.
• 600 KVA/415 V Diesel Generator
• ACB 1250 Amp – 2 No’s.
• APFC – 800 KVA.
• BMS Automation System and Fire Alarm System.
• Centralized A/C Plant 100 TR – 3 No’s, AHUs and FCUs.
• Boilers 600 Kg/h, and All Hotel Kitchen Equipments.
In addition to O&M Involving our other new 230 rooms Project at Nandanam, Annasalai.
(The RainTree Hotel)
Handling project activities of:
• 1000KVA, 11KV/433V, Dry type Transformer-2 Nos.
• 750 KVA, 415V, Diesel Generator 2 no’s with AMF and Auto Synchronizing Panel.
• 250 TR Water Cooled Screw Chiller -3 Nos., AHU’S with different range.
• HT (11KV) & LT Panel with different range of VCB’S and ACB’S, Make: Megavin, L&T.
• AMF Panel with, Lightning Arrestors, Inverters.
• Elevators, Starters, Exhaust fan, Blowers and pumps with different range.
• Firefighting sprinkler & Hydrant system.
• Fire Alarm, Public address, Access control, CCTV with monitoring DVR recording system.
• Integrated Lighting design in Lobby (Coffee shop, Entrance lobby, Indian Restaurant & Bar) &Banquet (Conference Hall, Pre Function & Banquet Hall) Level.
• BMS, Boiler, Plumbing System, Water and Sewage treatment Plant.
Involving working out various requirements with respect to utilities, equipment’s,manpower & monitoring overall project operations for ensuring timely completion.
Co-ordination of Drawings carried out.
5. June 8th 2001 to June 31th 2008 with M/S LE ROYAL MERIDIEN CHENNAN as Assistant Manager.
Handling Operation & Maintenance of:
• 11KV/433v Indoor H.T Sub-Station.
• 11KV-630A HT VCB.( ANDREW YULE & CO )
• 1600KVA11KV/433V Transformer-2nos
• 2000KVA, 8.5-11.5KV/11KV automatic Voltage Regulator (outdoor type)
• 1250KVA, 415V diesel Generator with AMF and Auto Synchronizing Panel. (2 no’s)
• Centralized A/C plants 350Tons-3 no’s AHU’s and FCU’s
• ACB 3150 AMP (1 no) / ACB 2000Amps (4nos) / ACB 800Amps (10nos)
• APFC Panel –1000KVA
• PCC Panel, MCC Panels, MV Panel, PDB, LDB and Starters.
• BMS Automation system.
• Fire Alarm and Sprinkler System., 600Kg/h Boilers (4 No’s) And all Hotel Equipment.
6. Aug-01st 1999 to May-05th 2001 with M/S SANTHOS HOSPITAL (PVT) LTD.
As Electrical Supervisor
Handling Operation & Maintenance of:
• 11KV out Door Sub Station, 630 KVA
• Transformer, MV Panels, SSB, DB and ALL Hospital Equipment.
• Operation and Maintenance of 250 KVA KIRLOSKAR Diesel Generators.
• Operation and Maintenance of 60-TON CHILLER PLANT, AHU and FCU.
7. November-19th 1996 to July-15th 1999 with M/S AHELIA SWITCH GEAR CO Kuwait
As PRODUCTION SUPERVISOR (First ISO Company in Kuwait)
Manufacture, Assembly and Wiring of
• 11 KVA VCB, 11 KV Switch Board, LV Board, MCC, MLTB,
• SMBS, MSB, and All Type of DBs.
8. May 1st 1989 to November 10th 1996 with M/S MADRAS HI-TECH CIRCUIT LTD.
As ELECTRICAL TECHNICIAN ( Plot No C8 & C9, MEPZ, Tambaram, Chennai – 45)
Handling Operation & Maintenance of:
• 11 KV out Door Sub – Station.
• HT OCB (1 No)
• 750 KVA Transformer (1 No)
• 500 KVA DG Set (2 No’s)
• 40 Ton Chiller Plants (2 No’s)
• PCB Manufacturing Equipment.
EDUCATIONAL PROFILE:
1. SSLC at Sankar higher Secondary school, Sankari West, Salem Dt.
2. Diploma in ELECTRICAL AND ELECTRONICS Engineering
At Sankar Institute of Polytechnic, Sankar Nagar, Tirunelveli Dt.
3. B - Tech ELECTRICAL AND ELECTRONICS Engineering
At J.R.N Rajasthan Vidyapeeth ( Deemed-to-be) University. Udaipur, Rajasthan.
ADDITIONAL QUALIFICATION:
1. Electrical Supervisor Competency Certificate. C-19699.
(Issued by Tamil Nadu Licensing Board)
Work Experience: Total 29 Years.
PERSONAL DETAILS:
Name : M.VELMURUGAN
Father Name : S.R.Madasamy
Date of Birth : 15-05-1969
Address for Communication : No 4.9, Bharath Nagar 2nd cross street,
Bharath Nagar, Madipakam,
Chennai – 600 091.
Ph: 960*******, 730-***-****
DECLARATION
I hereby declare that the above furnished details are true and correct to the best of my
Knowledge
Date: Signature
Place: CHENNAI (VELMURUGAN .M)