CURRICULUM VITAE
Name : GANESAN KANNAN
Experience : 4 Years
Position : Testing & Commissioning Engineer(Protection)
Nationality : Indian
E mail : adizv6@r.postjobfree.com
Mobile : +917*********(India)/+973********(Bahrain)
CARREER SUMMARY
Practical site work experience in Testing & Commissioning of High Voltage, Low Voltage Switchgear, Relay Control Panels, Schemes, Transformers, Switchgear control
Interlocks at Kahramaa Substation Qatar. Witness Job for Distribution Substation at Qatar Military Troops Projects. Plant Maintenance of electrical equipment as Training Engineer at JSW steel Bellary and NTPC Farakka.
PROFESSIONAL QUALIFICATION
Bachelor of Engineering In Electrical & Electronics Engineering
Year of completion : April 2014
Post Graduate Diploma Course in Thermal Power Plant Engineering
Year of completion : April 2015
CAREER HISTORY
Organization : Winstar Electromechnical Works WLL., Qatar.
Designation : Protection Engineer (Testing & Commissioning) .
Period : August 2016 to September 2019
Organization : Voltech Engineers Private Limited., Bahrain.
Designation : Protection Engineer (Testing & Commissioning) .
Period : December 2019 to Till Now
SKILLS HIGHLIGHTS
Skilled in all types of scheme checking such as transformer protection, differential schemes, stability schemes, RTCC schemes,Load Shedding stage controls and interlocks and other control circuit schemes with various systems.
Skilled to test and commission of Protection system Relays and switch gear
equipments such as Current Transformer,Voltage Transformer, Circuit Breaker,
Isolator, Earth Switch and Unit Transformer.
Skilled to test various Numerical protection relays of Siemens,ABB,Alstom and
reyrolle make having protections such as Differential Protection,Restrictred Earth Fault, Over current, Earth fault, Thermal overload protection, Under voltage and
Over voltage protections.
Experienced to do HV Test for Power Cables and Bus bars rated up to 400kV and Knowledge of all Differential Protection such as Power Transformer,Busbar and REF Protection
Preparing inspection Schedule with consultant for system approval. Coordinating with client,consultant, contractor, subcontractor and supplier.
Working with PTW, LOA, Tag-In,Tag-Out, Padlock System, Hot Permit and Cold Permits for Safety formalities for all kind of Electrical Work.
Preparing Test packs and Ready for Inspection (RFI) schedule for consultant approval and compliance with necessary standards as per the client requirements.
Possess knowledge in Transformer protection, Transformer Differential Protection & REF Protection, Bus Bar protection, Motor protection, and synchronizing scheme.
Possess excellent interpersonal, leadership and managerial skills, commercially aware and capable of working well under pressure within a team.
Providing technical assistance to integrate Design based commissioning and Construction based implementation.
TEST KIT FAMILIARITY
• Sverker 780 Relay Test System
• Primary Injection tester various types
• Insulation Resistance Tester
• Primary Injection kit – Techno products, MEGGER 100
• Secondary injection Kit –Kocos,Omicron CMC256,CMC356
• Micro Ohm meter – Techno
• CT Analyser- Omicron
• Insulation Resistance Tester – Meggar and FLUKE
• CRM KIT-OMICRON
• Omicron Synchronizer
PROFESSIONAL EXPERIENCE - PROJECTS
Qatar Projects : 66/11 kV Museum Road Substation, 66/11 kV Maither Central Substation and 33/11kV Abu Samra Substation
Client : Kahramaa (PHASE-13)
Main Contractor : Siemens WLL
Duration : August 2018 – Until Now
Qatar Projects : 132/33kV AL BIDA METRO Substation, 132/11kV RAF SOUTH Substation and
66/11kV RAK Substation
Client : Kahramaa (PHASE-12)
Main Contractor : NCC/L&T
Duration : Sept 2017 – July 2018
Qatar Projects : 66/11 kV LUSAIL NORTH Substation, 66/11 kV LUSAIL QIS Substation and
66/11 kV LUSAIL WEST Substation
Client : Kahramaa
Main Contractor : ALSTOM
Duration : Jan 2017 – Sept 2017
Qatar Projects : 66/11kV PSS4 Substation, 66/11kV AL MERGAB Substation and
66/11kV Bu Fasila Substation.
Client : Kahramaa (PHASE-11)
Main Contractor : NCC
Duration : August 2016 – Jan 2017
Bahrain Project : 400kV Ras Legrain Grid Substation
Client : EWA
Main Contractor : Siemens
Duration : December 2019 – Till Now
FAMILIARITY OF RELAYS & TESTING
Transformer and Busbar Sensitivity & REF Stability test
Over current stand by earth fault relay checks
Directional over current relay & earth fault checks
Instantaneous over current relay & earth fault check
Under voltage & Over flux Relay
CT, CVT & PT testing. Summation CT Test
Primary Injection up to relay end
DC scheme & Trip logic Checks
Trip coil supervision circuit & Current measurement checks
Synchronize circuit operation check
Auto reclose Scheme checks
Auto Change over scheme check
Pilot wire protection relay
Busbar Differential check
Preparation of cable schedule & termination schedules
Testing & Calibration of all meters
Executing Kit Current Transfer Testing with End Client before Commissioning
Energizing HV And LV Side Transformer in Substation
Experience in Siemens Relays:
7SW – Under Voltage Relay
7SJ621 – O/C & E/F Relay
7SJ64-Syncro Check Relay
7SJ610-Line Differential Relay
7UT61 – Transformer Differential Relay
7SSD52- Cable Distance Relay
Experience in ABB Relays:
ABB –REF615 Directional & non Directional O/C & E/F Relay Protection Relays
ABB -REU 610,615 Undervoltage Relay
ABB -RED 670 Cable Differential protection relay.
Experience in AREVA/ALSTOM RELAYS:
MICOM - P122 - O/C & E/F Relays
MICOM - P922 Under voltage and over voltage
MiCOM- P111 Standby earth fault Protection Relays
And All AC & DC Auxiliary Voltage Relay
KHARAMA AUTHORITY APPROVALS:
AC/DC CHECKS
CT/VT PRIMARY AND SECONDARY INJECTION CHECKS
AUXILIARY AND BACKUP PROTECTION RELAY CHECKS
PILOT WIRE DIFFERENTIAL RELAY CHECK
BCU AND BI CHECKS
TCS CHECKS
TRIP LOGIC TEST
LOAD SHEDDING SCHEME CHECKS
BFI SCHEME CHECKS
BUS BAR TRIPPING TEST
RELAY FINAL SETTING
BUS BAR STABILITY
TRANSFORMER STABILITY
PERSONAL DETAILS
Date of Birth : 12 March,1993
Marital Status : Single
Father’s Name : Kannan
Languages Known : Tamil, English and Hindi
Passport No. : M1704964
E mail : adizv6@r.postjobfree.com
Mobile number : +917*********/+973********
Permanent address : Plot no.71,Maruthandamkuruchi,Tiruchirapalli,Tamilnadu,INDIA.
DECLARATION
I hereby declare that all above-mentioned information is in accordance with fact or truth up to my knowledge and I bear the responsibilities for the correctness of the above mentioned particulars.