Post Job Free

Resume

Sign in

Engineer Service

Location:
Lahore, Punjab, Pakistan
Posted:
November 07, 2020

Contact this candidate

Resume:

RESUME

FARHAN MANSOOR

Email: adhmoc@r.postjobfree.com

Cell: +923*********

Objective

I want To be a part of your prestigious organization where I could apply my knowledge and skills to exert and enhance the image and goodwill of the organization, that also satisfy my instincts for professional and career development to build and nurture long lasting employee and employer relationship. I have Experience Health Care IT PACS, CPACS, RIS HIMS, and Radiology Medical Equipment.

Professional Experience

TechnoMedics Pvt Ltd Feb – 2018 – Oct-2020

Distribution Manager / Advance Service Engineer

Training: CARERAY

Care View Maintaince Engineer, Calibration, Installation, CareCom Software Installation. 17 January, 2019

CHINA

Training: Millensys HealthCare and Technology Program 24-9-2018 to 26-9-2018

Egypt Cairo

Training: Millensys Installation and Technical Maintenance for Vision Tool Work Space (VNA / PACS / Reporting / Teleradiology) and Information Systems (MiRIS, MiBroker, MiClinic – EMR) October 04-2018

Egypt Cario

Radiant Medical Pvt.Ltd Assistant Technical Manager Carestream Health Sep -2014 - Feb - 2018 Service Training: CR Classic Elite CR Vita CR Max, Mammography Calibrations DR and Calibration, Image Suite, Direct View, Image View, Mammography Workstation, AT Lahore

23-28 Feb15

Service Training: DV6850, DV5950, DV5700 DV6950, MIM AT Lahore

2nd March 15 to 7th March 15

Carestream Vue PACS Training 1st Week Technical training AT DUBAI

17 April 16 to 21 April 16

- Installation and configuring OS/storage for installation of a workflow manager (PACS) - Installation and configuring OS for installation of a speech server for Vue Reporting - Installation of VMware ESXi,vSphere and configurations.

- PACS application training

Week 2nd: Application training

AT DUBAI

24th April 16 to 28th April 16

- Overview of advanced PACS features - Vue Reporting

- Database admin functionalities - IS Link - Vue explorer overview Monitoring and controlling Supervision National wide engineers and providing Support for problem escalation, visit customer site and support sales team on Technical sales matter Agfa HealthCare Pakistan Pvt.Ltd (Field Service Engineer) March 2012 - Aug 2014 HealthCare, Computed Radiography, DICOM interface, DICOM Printer, PACS. RIS Interface. 1. CR Installation CR 10X, CR 12, CR 15, CR 30X, CR 30xM 2. DICOM Printer Dry Star 5302, Dry Star 5300, Dry Star AXYS, Dry Star 5503 3. NX workstation Acquisition Software Installation Troubleshooting 4. QS Workstation Acquisition Software Installation Troubleshooting 5. Web PACS 1000

Medical Equipment and System (MES) Medequips Toshiba Medical System July -05-2010 _ Oct 2011 Service Engineer -II

CT scan Group work as Service Engineer –II, Toshiba Ct scan Single Slice to 64 Slice. 1. Installation of CT Scan

2. Complete DB configuration layout and Electrical Complete Working 3. Service Repair escalation of Faults

4. PPM

1. Clean Slip Ring and adjust the alignments using Jig Alignments Tools 2. Checking Electrical Breakers and Ensure Their Performance. 3. Service Power Generators and Check the IGBT Calibrate the Power Generator also. 4. Service Tube Head and Cooler, Calibrate

5. Service Detector and Check the Performance.

6. Service The Patient Couch and Center alignments 7. Service the S-Con and D-Con with Displays

8. Service Injector

9. Service Recon Box

10. All Phantom and air calibration.

Scientific Supplies Pvt (Ltd) BeckMan Coulter April 2008 – June 2010 Service Engineer

1. Beckman Coulter Full Automatic Chemical Analyzer (Snychron Series 3x-7x) Repair Maintainers Calibrations PPM Clean Needles Update Calibration Data 2. Beckman Coulter Full Automatic Hematology Analyzer 5 part and 3 part (5 part Hmx Mxm) PPM

1. Clean WBC Chamber

2. RBC Chamber and Platelets Electrode

3. Replace all Silicon Tubing’s

4. Clean LASER and Calibrate LASER

5. Clean Flow Chamber

6. Clean Aspiration Needle

7. Adjust and Calibrate Rocker Bed

8. Calibrate Pneumatic and adjust the follow level 9. Run QC Level –I and Level –II and Level – III

Education

Preston Institute of Management Sciences & Technology Lahore Campus

BS.Tech Electronics) Honors

(Aug 2012)

CGPA 3.5

AL – KHAIR University AJK

Lahore Campus

B.Tech Pass 2 Year Program, ELECTRONICS

2007 - 2009

”A” Grade

PUNJAB BOARD OF TECHNICAL EDUCATION Lahore

Associate Diploma of Electronics,

Aug 2003 - Sep 2006

”A” Grade

BOARD OF INTERMEDIATE AND SECONDARY EDUCATION Lahore SCIENCE, Sep 2001

1st Division

OPTICAL FIBER TRANSMISSION SYSTEM & CABLE JOINTING Optical Fiber Cable Installation, Splicing, Testing

(OTDR, Power Source)

Telecom Foundation (PTCL) Lahore.

Certificate Primavera P6. Professional R 8.3

Successfully Completed the 20 Hrs.

03-2014

Responsibilities

Commissioning, Installation, troubleshooting / Repair / Preventive maintenance, Calibration, after sales support, Contract and Management.

Projects

Mammography Computed Radiology system calibration with third part Radiology system. Pakistan first National wide Tele Radiology and PACS setup Implantations Installation, Configuration, after sales service with Support. Health Care IT Consultancy. Skills

1. Network / Hardware Desk Support Service

2. LAN / WAN Monitoring, Maintain, Troubleshooting, VPN, Remote Access, Firewall 3. SQL Database,Management Studio, IIS, Web Services, Windows Server 2008 – 2012R2 – 2016, Windows 10, Windows 8.1, 7,XP

4. Basic Programing Skills C++, Java, HTML, DHTML, Python 5. PACS, CPACS, RIS, HIMS, DICOM, mini PACS WorkStation, PACS Data Migration, Backup 6. Linux Installation, basic knowledge.

7. VMware ESXi,vSphere

8. RAID 0,1,5,6,10

9. DELL / HP Server, Workstation and Storage SAS / SAN / NAS VMware ESXi,vSphere 10. Cyber Security, Network Analyzer, Block Attacks, Secure Live IP and Local Address,antiviruse Server Edition / Enterprise Edition Configuration. 11. Data Recovery as per Case and Situation.

Certifications

1. Diploma in Computer Hardware 6 Month Computer Hardware Troubleshooting Repair.

2. Certificate Primavera P6. Professional R 8.3

3. Carestream Health (Dubai)

4. Millensys Health Care IT (Egypt)

5. Care Ray XFPDM (China)

RESUME SUBMITTED IN CONFIDENCE



Contact this candidate