Post Job Free

Resume

Sign in

Electrical Maintenance

Location:
Abu Dhabi, United Arab Emirates
Posted:
October 09, 2020

Contact this candidate

Resume:

K.MOHAN Email id: adgsyd@r.postjobfree.com

Mobile No: +971-*********)

• Post Applied For : Electrical Maintenance foreman(Permit Holder)

• Total Experience : 26 Years ( 14 Years in Oman)

Technical Educational Qualification:

Course Name of Institution Board / University Year of passing National Trade

Certificate

Electrical,(Diploma Two

years)

Govt. I.T.I Vellore

Tamil Nadu, India.

Industrial Training

Institute

July 1979

National Apprenticeship

Certificate,(Diploma

one year)

GEC of India, Chennai,

Tamil Nadu, India.

Electrical Technician December 1982

Academic Educational Qualification:

Course Name of Institution Board / University Year of Passing Pre University course

Muthurangam Govt Arts

College

University of Madras March 1978

Secondary School

Certificate

Sri Venkateswara High

School

Board of Secondary

Education, Chennai

March 1977

Other Certificates:

• CEP Certificate Of Electrical Authorization Person Issued by PDO

• Holding Permit Holder License issued by PDO.

• Electrical License Issued by TNELB (Tamil Nadu Electrical Licensing Board) India Summary of Service Executed:

Sl. No Employer Position Held Duration

1)

SEEH AL SARYA ENGINEERING

LLC, Oman

Electric

Foreman(Permit

Holder and Competent

Electrical Person)

Apr 2017 to Apr 2020

(3 Years)

2)

RAS GAS – INVENSYS

PROJECT. Qatar – Madina

Group W.L.L

Electrical

Foreman

Mar 2016 to April 2016

For Shut down job

3)

Petroleum Development Of

Oman Seconded by Special

Electrical

Foreman

Jan 2008 to Nov 2015

Technical Services - Oman (8 Years)

4)

Petroleum Development Of

Oman Seconded by Larsen &

Toubro Electromech LLC,

Oman

Electrical

Technician

Aug 2005 to Aug 2007 (2

Years)

5)

Ministry of Electrical and

Water Seconded by Global

Chemicals & Maintenance

Systems LLC, Oman

Elect. Tech.

Apr 1997 to Sep 1999

(2 Years)

6)

The Ambur Co-operative

Sugar Mills Ltd, TamilNadu,

India

Elect. Tech.

Mar 1983 to Mar 1995 (12

Years)

Nature of Works:

• Operation, maintenance and troubleshooting works for all Kinds of Electrical Equipment’s In Petroleum Development Oman Crude Oil Gathering Station, Gas Wells and Power Grid Station.

• Operation, maintenance and troubleshooting Works for all kinds of Electrical Equipment’s in Ministry of Electrical and Water, Oman

Working With Following Electrical Drives System and Controls:

• 132/33KV,33KV/415V Power and Distribution Transformers

• Generators: 2000KW, 800KW Turbo Generators, 250KW Diesel Generators.

• 33KV,11KV,6.6KV, 415V Switch Gears and Panels

• 11KV,6.6KV,415V Motors

• High, Medium and Low Voltage Power and Control Cables & Glanding

• 11KV,6.6KV, 415V Motor Control Center Panels and Starter

• Protection Relays

• Grid Earthings

• VSD ( Variable Speed Drive) Motors

• CT and PT

• Batteries and Battery Chargers

• UPS System ( Uninterrupted Power Supply System )

• Power and Control Circuit

• Industrial Lightings

• PDB and LDB

• MOV

• Cathodic Protection Rectifier (CPR)

• Fire and Gas

• Electrical Testing Equipment’s

• Zone 0,Zone1,zone 2 Hazardous Area Classification and PTW

• Plant Start up and Shut down Activities

Nature of Job Responsibilities:

• MAINTANENCE BACKGROUND: Carried out day by day preventive, corrective and break down maintenance activities on Electrical Systems, Plant And Equipment’s Assigned Field Covering Generators And Controls, LV/HV Motors and Control Circuits, Transformers, MVSG HVSG Cables, 33KV Overhead Lines, Electrical Submersible Pumps, VSD Motors, UPS System, Batteries and Battery Chargers, Lightings.

• To Perform Troubleshooting, Identifying, Isolating, Repairing and Testing of Faulty Electrical Components and Circuits. To Respond To Emergency Call Outs, Troubleshooting the Problem and Take action to ensure the correct operation of the Electrical Equipment.

• Reporting of Hazardous and Near Miss to HSE Department and Regularly Participate in HSE meetings.

• ELECTRICAL SYSTEM ISOLATION: Carried out Electrical System 33KV and 11KV out door and in door substation isolation and De-Isolation for Log out, Tag out and Multi lock System for Operation, Instrument, Mechanical, and Electrical as per HSE Policies and Maintain log book.

• TRANSFORMER: Preventive, corrective and breakdown Maintenance activities and troubleshooting of 33KV, 11KV, 415KV indoor and outdoor type up to 20MVA Power transformer and Distribution Transformers.

• GENERATOR: Maintenance, and Troubleshooting of Generators, Control Panel Parameters, Automatic Changeover Switch, Mechanical Changeover Switch Interlocking system, AVR and alternators up to 250KVA Kirlosker make.

• H.T AND L.T MOTORS: Preventive, corrective and breakdown maintenance activities, Installations, Commissioning, Testing, Overhauling, Maintenance and Troubleshooting of HV,MV,LV Motors, Breakers, DOL and Star Delta Starters 11KV,6.6KV and 415V.

• HV MV and LV POWER AND CONTROL CABLES GLANDING: Cable Laying, glanding, Testing

,loop Checking, Termination and using Cable Lugs of cables up to 200 sq mm, MICC PVC XLPE, PILC, Multi Core and Single Core Cables etc.

• CT AND PT: Installation, Testing and Maintenance of CT & VT. Measuring and Protection of Relays of the feeder Transformers, Generators and Motors etc.

• BATTERIES AND BATTERY CHARGERS: Installation, Commissioning, Testing, and Maintenance of Batteries, and Battery Chargers for Lead Acid Battery and Alkaline Battery for Soft, Knife, HBL, Alcad and Chloride for control power to HV & LV switch boards.

• UPS SYSTEM: Installation Commissioning Testing, Maintenance and Troubleshooting of UPS up to 30KVA 415V, 240V/ for DCS, instruments controls, SCADA and PLC.

• CPTR: Maintenance and Troubleshooting of Cathodic Protection Transformer Rectifier using Pipelines and vessels for avoid corrosion.

• EARTHING SYSTEMS: Installation Commissioning Testing and Maintenance of all Type of Grid Earthing Network for all Electrical Equipment, Vessels, Tanks & Neutral earthing. Testing and Measuring of resistance values.

• LIGHTINGS: Erection, Commissioning, Testing, Maintenance and Trouble Shooting of All Types of Lightings for Hazard’s Area Explosion Proof Light Fittings.

• PROTECTION RELAYS: Motors, Transformers, Generators and Feeder Relays over Current, Earth Fault, Restricted Earth Fault, and Thermal over Current Relay, Winding Temperature Relay Commissioning and Testing with primary and secondary current Injection Test Kit.

• ELECTRICAL TESTING EQUIPMENT: Using of Megger, AVO Meter, Cable Route Locator Fault Locator, Hi-Pot Test Kit, Earth Megger, Phase Sequence Meter, Taco Meter Phasing Stick Earth Stick all type of Electrical Equipment’s Testing in hazardous area using intrinsically safe meter used.

• ZONE CLASSIFICATION: - Zone 0, Zone 1 and Zone 2 Hazardous Classification Obtain Safe Work Permits like Cold and Hot.

• DRAWINGS: - ALL HIGH/LOW VOLTAGE Reading Power and Control Circuit for PCC, MCC panels Personal Profile:

Father Name : P.S. Kumbeswar

Date of Birth : 05.05.1960

Nationality : Indian

Religion : Hindu

Marital Status : Married

Passport Details:

Passport No. : M5983230

Place of Issue : Chennai, India

Date of Issue : 07.04.2015

Date of Expire : 06.04.2025

Permanent Address:

404, Fathima SuperMarket Building, Tourist Club Area, Abu Dhabi.UAE Mobile: : UAE: +971-*********

Language Known: : English, Tamil, Telugu, Malayalam and Hindi Email Id: : adgsyd@r.postjobfree.com

Declaration:

I hereby declare that all the information stated above are true and correct to the best of my knowledge and belief.

(K.Mohan)



Contact this candidate