K.MOHAN Email id: adgsyd@r.postjobfree.com
Mobile No: +971-*********)
• Post Applied For : Electrical Maintenance foreman(Permit Holder)
• Total Experience : 26 Years ( 14 Years in Oman)
Technical Educational Qualification:
Course Name of Institution Board / University Year of passing National Trade
Certificate
Electrical,(Diploma Two
years)
Govt. I.T.I Vellore
Tamil Nadu, India.
Industrial Training
Institute
July 1979
National Apprenticeship
Certificate,(Diploma
one year)
GEC of India, Chennai,
Tamil Nadu, India.
Electrical Technician December 1982
Academic Educational Qualification:
Course Name of Institution Board / University Year of Passing Pre University course
Muthurangam Govt Arts
College
University of Madras March 1978
Secondary School
Certificate
Sri Venkateswara High
School
Board of Secondary
Education, Chennai
March 1977
Other Certificates:
• CEP Certificate Of Electrical Authorization Person Issued by PDO
• Holding Permit Holder License issued by PDO.
• Electrical License Issued by TNELB (Tamil Nadu Electrical Licensing Board) India Summary of Service Executed:
Sl. No Employer Position Held Duration
1)
SEEH AL SARYA ENGINEERING
LLC, Oman
Electric
Foreman(Permit
Holder and Competent
Electrical Person)
Apr 2017 to Apr 2020
(3 Years)
2)
RAS GAS – INVENSYS
PROJECT. Qatar – Madina
Group W.L.L
Electrical
Foreman
Mar 2016 to April 2016
For Shut down job
3)
Petroleum Development Of
Oman Seconded by Special
Electrical
Foreman
Jan 2008 to Nov 2015
Technical Services - Oman (8 Years)
4)
Petroleum Development Of
Oman Seconded by Larsen &
Toubro Electromech LLC,
Oman
Electrical
Technician
Aug 2005 to Aug 2007 (2
Years)
5)
Ministry of Electrical and
Water Seconded by Global
Chemicals & Maintenance
Systems LLC, Oman
Elect. Tech.
Apr 1997 to Sep 1999
(2 Years)
6)
The Ambur Co-operative
Sugar Mills Ltd, TamilNadu,
India
Elect. Tech.
Mar 1983 to Mar 1995 (12
Years)
Nature of Works:
• Operation, maintenance and troubleshooting works for all Kinds of Electrical Equipment’s In Petroleum Development Oman Crude Oil Gathering Station, Gas Wells and Power Grid Station.
• Operation, maintenance and troubleshooting Works for all kinds of Electrical Equipment’s in Ministry of Electrical and Water, Oman
Working With Following Electrical Drives System and Controls:
• 132/33KV,33KV/415V Power and Distribution Transformers
• Generators: 2000KW, 800KW Turbo Generators, 250KW Diesel Generators.
• 33KV,11KV,6.6KV, 415V Switch Gears and Panels
• 11KV,6.6KV,415V Motors
• High, Medium and Low Voltage Power and Control Cables & Glanding
• 11KV,6.6KV, 415V Motor Control Center Panels and Starter
• Protection Relays
• Grid Earthings
• VSD ( Variable Speed Drive) Motors
• CT and PT
• Batteries and Battery Chargers
• UPS System ( Uninterrupted Power Supply System )
• Power and Control Circuit
• Industrial Lightings
• PDB and LDB
• MOV
• Cathodic Protection Rectifier (CPR)
• Fire and Gas
• Electrical Testing Equipment’s
• Zone 0,Zone1,zone 2 Hazardous Area Classification and PTW
• Plant Start up and Shut down Activities
Nature of Job Responsibilities:
• MAINTANENCE BACKGROUND: Carried out day by day preventive, corrective and break down maintenance activities on Electrical Systems, Plant And Equipment’s Assigned Field Covering Generators And Controls, LV/HV Motors and Control Circuits, Transformers, MVSG HVSG Cables, 33KV Overhead Lines, Electrical Submersible Pumps, VSD Motors, UPS System, Batteries and Battery Chargers, Lightings.
• To Perform Troubleshooting, Identifying, Isolating, Repairing and Testing of Faulty Electrical Components and Circuits. To Respond To Emergency Call Outs, Troubleshooting the Problem and Take action to ensure the correct operation of the Electrical Equipment.
• Reporting of Hazardous and Near Miss to HSE Department and Regularly Participate in HSE meetings.
• ELECTRICAL SYSTEM ISOLATION: Carried out Electrical System 33KV and 11KV out door and in door substation isolation and De-Isolation for Log out, Tag out and Multi lock System for Operation, Instrument, Mechanical, and Electrical as per HSE Policies and Maintain log book.
• TRANSFORMER: Preventive, corrective and breakdown Maintenance activities and troubleshooting of 33KV, 11KV, 415KV indoor and outdoor type up to 20MVA Power transformer and Distribution Transformers.
• GENERATOR: Maintenance, and Troubleshooting of Generators, Control Panel Parameters, Automatic Changeover Switch, Mechanical Changeover Switch Interlocking system, AVR and alternators up to 250KVA Kirlosker make.
• H.T AND L.T MOTORS: Preventive, corrective and breakdown maintenance activities, Installations, Commissioning, Testing, Overhauling, Maintenance and Troubleshooting of HV,MV,LV Motors, Breakers, DOL and Star Delta Starters 11KV,6.6KV and 415V.
• HV MV and LV POWER AND CONTROL CABLES GLANDING: Cable Laying, glanding, Testing
,loop Checking, Termination and using Cable Lugs of cables up to 200 sq mm, MICC PVC XLPE, PILC, Multi Core and Single Core Cables etc.
• CT AND PT: Installation, Testing and Maintenance of CT & VT. Measuring and Protection of Relays of the feeder Transformers, Generators and Motors etc.
• BATTERIES AND BATTERY CHARGERS: Installation, Commissioning, Testing, and Maintenance of Batteries, and Battery Chargers for Lead Acid Battery and Alkaline Battery for Soft, Knife, HBL, Alcad and Chloride for control power to HV & LV switch boards.
• UPS SYSTEM: Installation Commissioning Testing, Maintenance and Troubleshooting of UPS up to 30KVA 415V, 240V/ for DCS, instruments controls, SCADA and PLC.
• CPTR: Maintenance and Troubleshooting of Cathodic Protection Transformer Rectifier using Pipelines and vessels for avoid corrosion.
• EARTHING SYSTEMS: Installation Commissioning Testing and Maintenance of all Type of Grid Earthing Network for all Electrical Equipment, Vessels, Tanks & Neutral earthing. Testing and Measuring of resistance values.
• LIGHTINGS: Erection, Commissioning, Testing, Maintenance and Trouble Shooting of All Types of Lightings for Hazard’s Area Explosion Proof Light Fittings.
• PROTECTION RELAYS: Motors, Transformers, Generators and Feeder Relays over Current, Earth Fault, Restricted Earth Fault, and Thermal over Current Relay, Winding Temperature Relay Commissioning and Testing with primary and secondary current Injection Test Kit.
• ELECTRICAL TESTING EQUIPMENT: Using of Megger, AVO Meter, Cable Route Locator Fault Locator, Hi-Pot Test Kit, Earth Megger, Phase Sequence Meter, Taco Meter Phasing Stick Earth Stick all type of Electrical Equipment’s Testing in hazardous area using intrinsically safe meter used.
• ZONE CLASSIFICATION: - Zone 0, Zone 1 and Zone 2 Hazardous Classification Obtain Safe Work Permits like Cold and Hot.
• DRAWINGS: - ALL HIGH/LOW VOLTAGE Reading Power and Control Circuit for PCC, MCC panels Personal Profile:
Father Name : P.S. Kumbeswar
Date of Birth : 05.05.1960
Nationality : Indian
Religion : Hindu
Marital Status : Married
Passport Details:
Passport No. : M5983230
Place of Issue : Chennai, India
Date of Issue : 07.04.2015
Date of Expire : 06.04.2025
Permanent Address:
404, Fathima SuperMarket Building, Tourist Club Area, Abu Dhabi.UAE Mobile: : UAE: +971-*********
Language Known: : English, Tamil, Telugu, Malayalam and Hindi Email Id: : adgsyd@r.postjobfree.com
Declaration:
I hereby declare that all the information stated above are true and correct to the best of my knowledge and belief.
(K.Mohan)