Objective
With an experience in the field of Testing Commissioning and
Maintenance of power system products, I look forward for an
opportunity to display my skills in the field of Testing &
commissioning, Maintenance and Execution of projects related to
power systems.
Academic Profile
2014 – B.Tech (EEE), PRASIDDHA COLLEGE OF
ENGINEERING AND TECHNOLOGY, AMALAPURAM,
( Affiliated to JNTU Kakinada) - 72%
Work Experience
Company Name
VOLTECH Engineer's
Pvt., Ltd., Chennai.
Designation
Senior-Testing &
Commissioning
Engineer
Experience
July,2014
to Till Date
Contact. No :
Mobile : +91-909*******
Home : +91-850*******
E-mail :
adgo8e@r.postjobfree.com
Address :
D No.1/1, V.Kamatchipuram,
Boduvarpatti Village, Usilampatti, Madurai district,
625537, TamilNadu.
Personal Data :
Date of Birth
: 20/02/1992
Skill Set
Having an experience and knowledge in the field of Testing,
Commissioning of LT,HT, GIS & AIS Substations. Power System
Transmission,Generation & Distribution, Electrical machines
Operation and Maintenance of Power Transformer, Circuit
Breakers and all Substation Equipment's with Knowledge of
Circuit Boards, Drawings, Electrical Equipment's and its
protection, and Computer Hardware and Software(MS Word,MS Excel & MATLAB.).
Technical Competencies
Gender
: Male
Father's Name :Raja Rao
Nationality
: Indian
Marital Status : Single
Languages Known
: Telugu, Hindi,
English & Tamil
Passport No. :M4679314
Submitted a paper Presentation Regarding on AUTOMATIC
STREET LIGHT CONTROL USING LIGHT DEPENDENT
RESISTOR at PRASIDDHA COLLEGE OF
ENGINEERING AND TECHNOLOGY,
AMALAPURAM.
Personal Competencies
Validity
: 17/12/2024
Experience
: 3 Years 4 Months
I am an adventurous and self-assured person.
Always ready to learn new things from basics.
Team spirit & Good listener.
Easily adapt to new environment, punctual and quick learner.
Work Expertise
RESPONSIBILITIES :
Deft in Testing & Commissioning of Switchyard & Switchgear, GIS.
Testing of CT, PT, CVT, LA, Circuit breaker, Isolators, AC &
DC Motors and Switch gear equipment.
Testing and commissioning of Autotransformer, Reactor, Motor with
Differential, & REF protection.
Special testing for Breaker Timing & CRM.
Scheme checking of control and relay wiring circuit, interface from yard
equipment to Control & Relay Panel with interlocks for Transformer, Bus
Coupler & Line Bays.
Scheme checking of HT< panel and auto change over scheme checking.
High Potential (Hi-POT) test for cables, bus bars and bus ducts.
Modification of the cable schedule & wiring circuit as per customer & System
requirement.
Submission of As-build cable schedule, scheme drawing & test reports.
Operation and Maintenance of Power Plant and sub-station.
Trouble shooting of all Electrical circuits, control and protection circuits.
Prepare test protocols for substation equipments & obtain customer approval.
.
Domestic Experience:
1. Project
Client
Through
: 220KV GIS JAMNAGAR (GUJARAT)
: M/s RELIANCE.
: M/s. SIEMENS INDIA LTD.
Executed Testing & Commissioning of
Testing & Commissioning of 33kV/6.6kV/415V substation
AC motor testing and Commissioning
HT cables testing and Commissioning
Testing of 800kVA and 630kVA transformer
Inter-Trip and Interlock Checking
Checking of Earth Resistance in all LA Earth Bit Chamber,
As build Cable Schedule and Scheme Drawings Preparation.
Testing and commissioning of 500MVA transformer
500MVA Transformer Protection Scheme checking.
Transformer Stability Test.
Transformer Differential Protection & REF Protection
Testing & Commissioning of 415V Switchgear
Preparation and Submission of Protocols.
2. Project
Client
Through
:
:
:
220/400KV GIS BAGHAPAT (UP)
M/s PGCIL.
M/s. PGCIL.
Executed Electrical Maintenance of
Overall Maintenance of Gas insulated systems, Transformers, Battery Panel, Relay
Panel and Control room including Lightning protection system.
Ensuring steady state and transient stability, Load shedding and prevention loss of synchronism,
Maintaining the system frequency within targeted limits,Voltage control, reducing the reactive power
flow by compensation of reactive power, tap changing, Securing the supply by providing adequate line
capacity and facility for changing the transmission paths.
Data transmission via power line carrier for the purpose of network Monitoring, control and protection,
Determining the energy transfer through transmission lines and tie-lines, Fault analysis and pin-pointing
the cause and subsequent improvement and Securing supply by feeding the network at various
points through SCADA system.
Operation of Isolators, Circuit Breaker, Current Transformer, Potential Transformer, Earthing switch to
necessary conditions with proper precautions and procedures as instructed.
3.
Project : 400/220kV GIS BAGHPAT(UP)
Client: M/s. PGCIL LTD.
Through : M/s SEIMENS Ltd.
Executed Commissioning of
4.
Testing all Electrical Equipments (CT, CVT, CB, ISOLATOR, WAVE TRAP, LA).
Isolator Switching Scheme Checking.
Commissioning of 400kV&220kV panels.
Substation SCADA Operation and maintenance,
As build Cable Schedule and Scheme Drawing Preparation.
Project : 2 600MW THERMAL POWERPLANT NELLORE (AP).
Client: M/s. NCC LTD.
Through : M/s ABB Ltd.
Executed Commissioning of
Commissioning of 11kV&415V Swithgear panels.
Testing and commissioning of Power transformers
Transformer Protection Scheme checking.
Transformer Stability Test.
Transformer Differential Protection & REF Protection
Testing & Commissioning of 415V Switch gear
Preparation and Submission of Protocols.
Checking of Earth Resistance in all LA Earth Bit Chamber,
As build Cable Schedule and Scheme Drawing Preparation
Executed Commissioning of
5. Project : 130 MW SOLAR POWER PLANT, KARNATAKA.
Client: M/s. AZURE LTD.
Through : M/s SCHNEIDER Ltd.
Executed Commissioning of
Commissioning of 11kV/415V LT panel
Transformer Differential Protection & REF Protection
220kV Transformer Stability Test.
Checking of Earth Resistance in all LA Earth Bit Chamber,
6. Project : 765/400 KV GIS KANPUR (U.P).
Client: M/s. PGCIL LTD.
Through : M/s PGCIL LTD.
Overall Maintenance of Gas insulated systems, Transformers, Battery Panel, Relay
Panel and Control room including Lightning protection system.
Ensuring steady state and transient stability, Load shedding and prevention of loss of synchronism,
Maintaining the system frequency within targeted limits, Voltage control, reducing the reactive power
flow by compensation of reactive power, tap changing, Securing the supply by providing adequate line
capacity and facility for changing the transmission paths.
Data transmission via power line carrier for the purpose of network monitoring, control and protection,
Determining the energy transfer through transmission lines and tie-lines, Fault analysis and
pin-pointing the cause and subsequent improvement and Securing supply by feeding the network at
various points through SCADA system.
Operation of Isolators, Circuit Breaker, Current Transformer, Potential Transformer, Earthing switch to
necessary conditions with proper precautions and procedures as instructed.
Executed Commissioning of
Executed Commissioning of
Knowledge on Advanced Nemerical Relays
SEIMENS Relays
1.Feeder protection
2.Motor Protection
3.Transformer Differential
4.Cable Differential
ABB Relays
1.Feeder protection
2.Motor Protection
3.Transformer Differential
SCHNEIDER Relays
1.Feeder Protection
2.Motor Protection
GE Relays
1.Transformer Differential
Declaration