Post Job Free
Sign in

Electrical Engineer

Location:
Riyadh, Saudi Arabia
Posted:
October 22, 2020

Contact this candidate

Resume:

CURRICULUM VITAE

Personal details

Name : M.ASIF RAJA

Date of Birth: 21.07.1991

Nationality : Indian

Sex : Male

Marital Status: married

Mobile :+966-*********

Mail :**********@*****.***

Languages Known:

English, Hindi and Tamil

Passport Details:

Passport No. : L9106593

Place of Issue: MADURAI

Date of Issue : 25/04/2014

Expiry Date : 24/4/2024

Address:

No 17 ismail puram 8 street,

Munichalai,

Madurai -625009.

Tamilnadu-India

Objective

With an experience in the field of Testing and Commissioning of power system products, I look forward for an opportunity to display my skills in the field of Testing & commissioning, Maintenance and Execution of projects related to power systems.

Professional Details

Professional Qualification: B.E. 2012

Working Experience

Designation :Testing & Commissioning Engineer

Experience : 8 years

Skil Set

Having an experience and knowledge in Testing, Commissioning and Maintenance of power plant, substation and process plant and relay testing and configuration.

TESTING EQUIPTMENT HANDLED:-

OMICRON – CMC 256, CMC 356.

Nature of work

Testing and commissioning of all Electrical equipment from 415 volts to 765 KV System.

Inspection of control and relay panel, preparation of Test Report and cable schedule for sub-station, power plant, and process plant.

Testing and commissioning of control & relay panel for Transformer, Bus Coupler, Bus-Transfer, and Line feeder.

Testing and commissioning of power control centre and motor control centre.

Testing of Protective Relays for various needs.

Over current and earth fault relays

Knowledge of Transformer protection, Transformer Differential Protection & REF Protection, Bus Bar protection, and synchronizing scheme.

Testing of CT, PT, CVT, Circuit breaker, switch gear and Power Transformer

Operation and Maintenance of Power Plant and sub-station.

Trouble shooting of all Electrical circuits, control and protection circuits

Co-ordination with client in As Built Scheme drawing submission, test report submission,

As build cable schedule submission and all site activity to satisfy the customer.

Across Experience in Saudi Arabia

1. Project: Imam saud university-Riyadh,KSA

Executed Maintenance of

Transformer Annual maintenance.

Switchgear Maintenance

2. Project: SEC 8123-Riyadh,KSA

Executed Maintenance of

Switchgear Maintenance

Protection relay testing.

3.Project:Prince mugrin intelligence compound- Riyadh,KSA.

Executed Operation & Maintenance of

Transformer Annual maintenance.

Ring Main Unit Maintenance.

Generator maintenance.

Switch gear Maintenance

Across Experience in india

1. Project : 33/6.6/0.415KV Substation,ODHISHA

Client : IOCL

Through: ROHINI INDUSTRIAL limited.

Executed Testing & Commissioning of

Testing of Electrical Equipments

Testing of capacitor bank.

Scheme checking

25 MVA Transformer

Testing of Breakers

Testing of CT

Testing of CVT

Testing of Cable Hi Voltage Test

Intertrip checking

Interlocks

Busbar stability

Transformer stability.

2. Project : 765/400 kv substation,Indore

Client : PGCIL

Through : ABB

Executed Testing & Commissioning of

Testing of Electrical Equipments

Scheme checking

Testing of Breakers

Testing of CT

Testing of CVT

Intertrip checking

Busbar stability

3. Project : 220/132 KV SubStation,silvasa

Client : RELIANCE MANUFACTURES

Through : Siemens

Executed Testiong & Commissioning of

Testing of Electrical Equipments

Scheme checking

Testing of Breakers

Testing of CT

100MVA Transformer

4. Project : 400KV SWITHYARD substation,TILDA

Client : GMR

Through : SIEMENS

Executed Testiong & Commissioning of

Testing of Electrical Equipments

Scheme checking

Testing of reactor.

Testing of Breakers

Testing of CT

Testing of CVT

Intertrip checking

Busbar stability

5. Project : 765/400 KV SWITCH YARD SUBSTATION,BINA

Client : PGCIL

Through : ALSTOM

Executed Testing & Commissioning of

Scheme checking

Testing of Breakers

Testing of CT

Testing of CVT

Testing of Isolators and LA

6. Project : 220/132/33 KV GIS SUBSTATION,Kalinganagar,odhisha

Client : TATA STEEL LTD

Through : SIEMENS

Executed Testing & Commissioning of

Testing of Electrical Equipments

Scheme checking

200 MVA,100 MVA& 25 MVATransformer

Testing of CT

Testing of VT

Testing of Isolators and LA

Testing of Cable Hi Voltage Test

Busbar stability test for 132kv & 220 kv

Transformer stability,REF & SEF Protection checks.

Interlock and intertrip check from 220kv to 132 kv system.

Interlock and intertrip check from 132kv to 33 kv system.

RTCC panel scheme check.

Cable Line differential test .

Over current and earth fault relays configure and testing.

Career details;

Organization : Alfanar

Designation : Testing Engineer.

Duration :Nov 2015 to till date.

Organization : Voltech Engineers Pvt Ltd.

Designation : Testing and Commissioning Engineer.

Duration :June 2012 to sep 2015.

Declaration

I hereby declare that all the details furnished above are true to the best of my knowledge and belief.

Date : 22.10.2020 Yours truthfully

Place : Riyadh,KSA (ASIF RAJA)



Contact this candidate