S.AJITHKUMAR
E-mail : *************.***@*****.***
Mobile:+91 -979*******/902-***-****
OBJECTIVE:
Over 3+ years of experience in Electrical service in HV/LV projects. To associate myself
with a professionally driven esteemed organization by pursuing a challenging, responsible and
rewarding career and to apply my professional expertise, skills and enthusiasm in a position for
Career growth.
WORKING EXEPERIENCE:
COMPANY: M/S INEL POWER SYSTEM ENGINEERS (P) LTD
(An ISO 9001: 2008 Certificated Organisation)
CLIENT: SIEMENS LTD, GOA – Factory Testing.
PERIOD: JULY 2017 to till date
DUTYS AND RESPONSIBILLITYS:
TestingAnd Configuration of Relays.
Co-ordination with M/s Siemens, Kalwa Works-Mumbai and Goa, for Quality Control and Testing Control and Relay panels.
Co ordination with customer witness testing of Relay and C&R Panels. through knowledge in trouble shooting of Electrical schemes.
Protection schemes check with interlocks and intertrip.
DC logic testing of control and relay panels from 11kv to 765kv.
Proficiency ANSI code and Bill of Materials.
Proficiency in SLD’s for various busbar system.
Testing of various Tri-Vector and Multifunction meters using secondary injection kits.
Inspection of control and relay panels, Preparing test reports.
SKILLHIGHLIGHTS:
Skilled to Check Various Schemes of Relay and Control panels for all types of busbar from 6.6kv to 765kv.
Skilled in all types of scheme check such us Transformer Protection, Generator Protection, Feeder Protection, Motor Protection, interlocks and other control circuits with various system.
Skilled to test Various Numerical Relays Specially Siemens Relays having Protection such as Differential Protection, Busbar Differential Protection, Distance Protection, Over current & Earth Fault Protection, and Voltage Protection.
3 Months work experience in Siemens MV2.
Posses’ excellent interpersonal, Leadership and Managerial skills commercially aware and capable working well under pressure within a team.
NUMERICAL RELAY EXCEPERIANCE:
SIEMENS RELAYS:
7SJ80, 7SJ81, 7SJ61 Over Current and Feeder Protection Relays and it all types of series
7RW80 & 7RW60 Voltage Protection Relays and its all types of series
7SR242, 7SR224,7SR210,7SR11 & 7SR12 ARGUS Relays and its all types of Relays
7UT612, 7UT613,& 7UT63 Transformer Protection Relays and its all types of series
7SA52,7SA61, 7SA63 & 7SA64 Distance Protection Relays and its all types of series
7SD522 Line Differential Relay and its all types of series
6MD622 Bay-Control Unit and its all types of series
7SJ522 BusBar Protection Relay
ALSTOM RELAYS:
MICOM P40 AGILE Overcurrent Protection Relays
P441,P443,& P444 Distance Protection Relays
MICOM P743 BUSBAR Differential Protection Relay
SCHNEIDER RELAY:
P444 Line Differential Relay
SOFTWARE HANDELED:
DIGSI 4 (SIEMENS)
DIGSI 5 (SIEMENS)
REYDISP EVOLATION (REYDISP SIEMENS)
MICOM S1 AGILE (ALSTOM)
MICOM S1 STUDIO (ALSTOM)
ESAERGY STUDIO (SCHNEIDER)
TEST UNIVERSE (OMICRON CMC 353,356,253 & 256 )
DOBLE (6150E)
TEST KITS HANDELED:
3PH Secondary Injection Kit-(omicron CMC 353, 356,253,&256)
3PH Secondary Injection kit-DOBLE (Fe6 series)
HV Test Kit –Prayog
IR Test Kit – MEGGER
LIST OF PROJECTS EXECUTED :
PROJECT: 220/33kv RINL (RASTRIYA ISPAT NIGAM LIMITED)-VIZAG STEEL PLANT
CLIENT: DANILI INDIA
Works Handled:Testing ofTransformer, Line differential, and Feeder Protection Control and
Relay Panels (7UT61, 7SJ66, 6MD86, & 7SD6)
PROJECT: 220/132/66KV GETCO (GUJARAT ELECTRICITY TRANSMISSION CORPORATION) BABARA S/S
CLIENT: GETCO
Works Handled: Testing of Transformer, Line, and BusBar Protection Control and Relay panels (7SA522, 7UT613, P444,7SJ61,6MD85,&7SS52)
PROJECT: KPTCL 220/132KV GADAG S/S (KARNATAKA POWER TRANSMISSION CORPORATION LTD)
CLIENT: KPTCL
Works Handled: Testing of Transformer, Line, and control and Relay panels
(7SA522, 7UT613, P444, & 7SJ64)
PROJECT: PGCIL 765KV S/S (POWER GRID CORPORATION OF INDIA LTD)
CLIENT: PGCIL
Works Handled: Testing of Transformer, Line Distance, Line Reactor, BusBar, and Tie control and Relay panels (7SA522, 7UT613, P444, 6MD85 & 7SS52)
PROJECT: UPPTCL 132/33KV SITAPUR
CLIENT: UPPTCL
Works Handled: Testing of 132kv Transformer and feeder control and Relay Panels
(7SR242, 7SR220, & 7SJ801)
PROJECT: INDIAN STEEL AND WIRE PRODUCT LTD 33KV JAMSHADPUR S/S
CLIENT: INDIAN STEEL LTD
Works Handled: Testing of Transformer, BusBar, and Feeder control and Relay Panels
(7UT61, 7SJ611, & 7SS52)
PROJECT: PGCIL AGRA SOUTH 400/220KV S/S
CLIENT: PGCIL
Works Handled: Testing of Line Distance, Auto Transformer, BusBar Control and Relay Panels (7SA522, 7UT61, 7VK, 7SS52)
ACADEMIC QUALIFICATIONS
Bachelor of Electrical and Electronics Engineering (2014-2017) in SRI SAIRAM ENGINEERING COLLEGE (Anna University) at CHENNAI(CGPA: 7.2%)
Diploma in Electrical and Electronics Engineering (2011-2014) in ADHIPARASAKTHI POLYTECHNIC COLLEGE (DOTE) at MELMARUVATHUR (percentage: 92%)
SSLC in Government High school (2010-2011) at MADHURANTAKAM (percentage: 76%)
PERSONALE PROFILE :
Father Name :R.SRINIVASAN
Date of Birth :20-09-1995
Language Known :Tamil, English, and Hindi
Residential Address : 35/1 EAST PILLAIYAR KOIL STREET
KARUNGUZHI. CHENGALPATTU DT
.
DECLERATION :
I Hereby Declere That All Information Furnished Above is True to the best of my knowledge and
Belief.
DATE :03-05-2020 YOURS TRULY