Post Job Free
Sign in

Engineer Design

Location:
Fort Wayne, IN, 46805
Posted:
August 28, 2020

Contact this candidate

Resume:

Brief list of experience

*G Wireless Installer level 3/4

I worked in TDM, Verizon and AT&T Central Offices. I did Headend work for GCI in Alaska.

Installed equipment, pulled #2 cable, connected equipment to power.

Migrated fiber.

Punched down cat5 alarm.

Test and Turn up.

Connected equipment to BDFB.

Construction Node Upgrade Specialist Senior wireless installer Nokia Wireless installer Cyan

Work Experience

Construction Upgrade Specialist

Cox Communications - Las Vegas, NV December 2018 to March 2019

Created work orders for Node- Splits for Coxs hybrid fiber coax network

QA/QC daily work

Updated tracker daily.

Prepared work order packages for construction.

Responsible for project until closet documents signed off.

Lead CO Technician, Integration, Commissioning

Glow Networks

November 2017 to June 2018

PA/MD/VA Nokia Air-Scale 5G Project De-commission ALU BBU 9926

Installation, Commissioning and Integration of the Nokia Air-Scale BBU Technical lead able to interface with the customer in a professionally OSHA 10hr Certification: First Aid Certification

Experience with Verizon/Wind-Stream migration project 3+ years Responsible for E911 call testing and Speed testing at each site Specialize in migrations for AT&T and Verizon

Nokia Certified PTID (available upon request)

Performed cell site pre/post site surveys notating RU space, power, alarm condition. For closeout report

Design Engineer

OSP Field - Chicago, IL

July 2017 to October 2017

OSP design FTTC

Surveyed fiber path underground to Verizon sites

ISP placement using trenching, core drilling going into shelter

Pull boxes, conduit size, hand hole placement, core drilling, footages, and pictures.

Input data into Quick Base site tracking tool. Created power point document

OSP Engineer

Tilson Technology

August 2016 to April 2017

Mid-Atlantic Region (New Jersey)

Perform field survey audits for Node Candidate Review (NCR)

Update Site Tracker records: Sites; Projects; Action items; Candidates; Reports

Construction Coordinator for Distributed Antenna System installation process

Corning-Scope and Teko, DAS pole mounted antennas.

Input field notes into mobile apps: Fulcrum for NCR creation.

Ability to manage multiple projects and train junior personnel

Isolate faults using OTDR and light meter troubleshooting.

Performed PIM and Sweep fiber testing.

OSP Make Ready Engineer

Davey Tree (Google Fiber Charlotte, NC)

January 2016 to May 2016

On the job training for SPINA CALC 5, pole loading analysis software.

Fielding included height of attachments following the power poles for Google Network.

Gathered accurate field notes to input into laptop for pole loading analysis.

Red lined poles for Make Ready work to include, line clearing, tree trim and pole replacement.

QC Inspector (Contract)

OSP QA - Austin, TX

May 2015 to October 2015

QA/QC inspector for aerial placement of Google Fiber network. Verified height of attachment is compliant to NESC heights to insure poles are "make ready" for construction, that included: tree trim, line clearing, guy and anchor placement.

Verified HOA at telephone pole and mid-span locations

QA/QC aerial lineman work performing attachment

Facilities Engineer / Field Operations Technician

General Communications Inc. - Anchorage, AK

January 2014 to December 2014

Planned and implemented the design of plants, offices, to maximize the use of available rack space and improve efficiency.

Estimated costs related to layout design for equipment and materials, labor, monitored the construction process.

Researched production/processing equipment or fixtures for purchase and gathers data relating to their ability to meet organizational needs.

Created MOP's for head-end power and equipment to be rack mounted.

Make sure compliance of construction standards for audit content across multiple accounts. Facilities include: Head-end, Data Centers, and Cell Site, Microwave sites.

Created BOMs and gathered RF data for new installations

Provided OSP/ISP walkouts to gather info. for development of Statement of Work (SOW).

Experience troubleshooting HFC coax/fiber networks using OTDR's, Light meter

General Communications Inc. Anchorage, Alaska

Field Operations Technician

Performed field installs to support: Cable modem MSO SONET/Ethernet Gb network.

Fiber handling and cleaning

Installed 1RU and 2RU equipment and cabinets

Installed PDU racks, equipment cabinets, power panels

GR 1502 Central Office/Network Environment Detail Engineering

Worked with lug compression tools

Familiar with JMA/Teko products

Familiar with JDSU and other testing tools

Field Operations Technician ICON Communications (Verizon September 2011 to December 2013

Wind Stream Project)

Icon Communications/TDS Telexom.

Broadband Project Maine

Knowledge of COEI Engineering Standards: CO installs

Performed power verification and power up of equipment in the field.

Performed quality inspections of the places of aerial, buried fiber conduit runs.

Turned up fiber links to SFP/XFP's; perform fiber power testing and inspection.

Performed installation at cell site shelters and Charles boxes.

Installed CYAN Z Series Macedonian NID's, Elect 20amp fuse panels

Performed CO work mounting equipment.

Performed site survey ISP for cable, fiber tray, RU and available ports at BDFB as well as Telex panels for pe build and post close out.

Design Engineer

Kenton Group

February 2009 to April 2009

CAF II Projects) Iowa Market

Fiber to Cell Site, Wind-Stream KY and WV.

Performed R/W survey, encroachment, and barricades

Performed field work for underground and make ready pole assessments.

Performed field work for DOT road crossing for county roads and state highways.

Fielder

Video Ready Access

October 2007 to January 2009

AT&T Northern/Southern CA

Fiber to Cell Site Inspector, AT&T San Gabriel Joint Pole Audits.

Performed work for the design and installation of VRAD equipment.

Performed joint pole field survey and audit work.

Performed make ready audits using GEO 95, NESC pole knowledge

ISP/OSP Engineer Verizon California Market - Market, California, US January 2006 to October 2007

Performed field survey work for FTTP, FTTH, MDU and MTU work orders.

Performed pole guying and anchoring fielding for make ready poles.

Performed conduit, grounding and bonding field survey work,

F2 P-Commit on Premise for AT&T - Sacramento, CA June 2005 to December 2005

Responsible for P-commit F2 pair, run reports for various USOC codes.

Applied AT&T applications in performance of work orders.

Project Manager (Contract)

Acela Technologies, Inc.

January 2005 to December 2005 Fredrick, MD

Project Manager ISP for Hotel Rehab Project Marriott 5 Star

Pulled new Cat-5 copper cable to connect phone to modem in each room

Hired local techs to insure completion of project on time

Performed termination, testing and tagging

Created document plan for each room

Project Manager (OWNER)

Washington Integrated Technology, Inc. - Silver Spring, MD November 1995 to December 2004

Managed projects for telecom closet audit of 157 sites.

Project Manager: developed scope or work for job bid

Managed all redundant connections to for point to point communications.

Managed daily operations tech support for moves, adds, changes of

157 remote sites. Included 30+ installations for CAT3 and PBX.

Negotiated and awarded $2.8 million contract for MAC/PBX systems.

Scheduled and coordinated access for sub's and crews.

Performed cost estimates, blueprint take-offs and created BOMs.

Education

High school diploma

Anacostia High School

September 1973 to May 1974

Skills

•5G

•Ethernet

•Network Support

•Node.js

•Mobile Applications

•QA/QC

•Telecommunication

•LAN

•Mechanical Knowledge

Military Service

Branch: Navy



Contact this candidate