Post Job Free
Sign in

Power Plant Electrical Engineer

Location:
Vasant Nagar, Karnataka, India
Salary:
9l/annum
Posted:
August 13, 2020

Contact this candidate

Resume:

ASHWATH KULASEKAR

Field Application Engineer (Relay & Protection)

+91-984******* **.*****@*****.***

PROFILE SUMMARY

A Self- Driven Electrical Engineer with 3+ years of experience in the Commissioning & Field application of protection elements in a power grid generation and Transmission with an exposure in different kind of HV/MV/ LV Voltage levels completing the project with satisfaction of the end client on time without compromising the quality of work & with a willingness of learning furthermore towards its Design and Autonomation

EDUCATIONAL QUALIFICATION

Graduation: ANNA University Board / PANIMALAR Engineering College, Chennai

B.E (E.E.E) CGPA:7.12 / 10 – Year of Completion 2012

Schooling: Higher Secondary Board of Examination/ Velammal Higher Sec Sc, Chennai

% Of Marks – 85.16 / 100 – year of Completion 2008

WORK EXPERIENCE’S: -

GIS SITE CO-ORDINATOR (Apprenticeship) @ TamilNadu Electricity Board, Chennai, from september-2016 to May -2017

PROTECTION ENGINEER @ Voltech Engineers Private Limited, Chennai, from Novemeber-2017 December - 2019.

PROTECTION ENGINEER @ Voltech Engineers Private Limited, GCC (Bahrain), from December-2019 to till now

SCOPE OF WORK: -

Testing and configuration of Numerical Relays.

Analyzing engineering drawing and performing correction over the drawings as per the site requirements.

Analyzing and modification of programmable soft logics in Numerical Relays as per requirements.

Team coordinator for quality control projects

PRIMARY & SECONDARY TEST KIT HANDLED: -

OMICRON CMC 256, CMC 256 PLUS & CMC 356 & CT ANALYZER

MEGGER SMRT410

PONOVO PW636i

CONFIGURATION AND TESTING KNOWLEDGE OF NUMERICAL RELAYS: -

SIEMENS MAKE

7SA522 - Line distance Protection Relay

7SD806, 7SD5 - Line Differential Protection Relay

7UM622 - Generator Protection Relay

7UT613, 633 - Transformer Differential Protection Relay

6MD66 - Bay Control Unit (BCU)

7SJ804 - Feeder Protection Relay

MICOM ALSTOM /SCHNEIDER MAKE

P443, P444 - Distance Protection Relays

P121&P127 - O/C & E/F Relay

P143, 141 - Feeder Management Relay

P643,645 - Transformer Protection Relays

P343,345 - Generator protection relays

P543, 545 - Line Differential Relay

NR (Nanjing nari) MAKE

PCS 902 - Distance Protection Relay

PCS 931 - Line Differential Relay

PCS 978 - Transformer Differential Relay

PCS 9611 - Feeder Protection Relay

GE MAKE

F650 - Bay control Protection Relay

G60 - Generator protection relay

T60 - Transformer Protection Relay

ABB RELAYS

RED 670 - Line Differential Protection Relay

REF 615 - Feeder Protection Relay

PROJECTS HANDLED

Project : 765/400 KV AIS PGCL, WARORA.

Customer : M/s. SIEMENS. Ltd.

Scope of Work : TESTING OF CRP PANELS.

Job Description: Configuration and Testing of Siemens & Alstom make Protection relays and Schematic Checks.

Project : 220 KV GIS POWER GRID, GHANDHIDHAM, GUJARAT

Customer : M/s. VESTAS. Ltd, M/S. SIEMENS. Ltd.

Scope of Work : TESTING OF CRP PANELS.

Job Description: Configuration and Testing of Siemens & Schneider make Protection Relays and Panel Scheme Checked.

Project : 400/220/66 KV GIS POWER GRID, TUGHKLAKABAD, HARYANA.

Customer : M/s. NR ENERGY. Ltd.

Scope of Work : TESTING OF CRP PANELS.

Job Description: Testing of relays and Schematic Checks

Project : 33 KV GIS, OIL REFINERY, BATHINDA, PUNJAB

Customer : M/s. HINDUSTAN MITTAL ENERGY Ltd.

Scope of Work : TESTING OF CRP PANELS.

Job Description: Configuration and Testing of Ge Protection Relays, Commissioning Support

Project : 150 MW STEAM POWER PLANT, OKKUR,KARAIKAL

Customer : M/s. NPPL PVT Ltd.

Scope of Work : TESTING OF RELAYS

Job Description: Testing of Alstom generator protection relays

Project : 220KV AIS SUBSTATION, WIND POWER PLANT, GUNTAKAL, ANDHRA PRADESH

Customer : M/S. SIEMENS GAMESA Ltd.

Scope of Work : CONFIGURATION AND TESTING OF REALYS

Job Description: Configuration and Testing of Siemens & Schneider make feeder Protection, Transformer Protection, distance Protection relays

Project : 220KV GIS SUBSTATION, RELIANCE OIL REFINERY, JAMNAGAR, GUJARAT

Customer : M/S. SIEMENS Ltd.

Scope of Work : CRP PANEL TESTING

Job Description: Configuration and Testing of Siemens & ge make line differential Protection, Transformer Protection, generator protection & multi Protection relays.

Project : 400 kV GIS, RAS LEGRAIN

Customer : M/S. SIEMENS Ltd. / M/S. EWA (BHARAIN)

Scope of Work : CRP PANEL TESTING

Job Description: Configuration and Testing of Siemens & ABB relays, preparation of SITE Acceptance Test Report With FAT, Schematic drawing Correction Performed As per Site Requirement, Signal checks For ICS Co-ordination, Trip logic Preparation

Date & place of Birth: 06/12/1990-Chennai

Father’s Name: DR K KULASEKAR

Mother’s Name: P SANKARESWARI

Nationality: Indian

Religion: Hindu

Marital Status: Single

Language’s Known: Tamil, English, Telugu (speak), Hindi (speak), German

Passion: Music (singing & instrumental), Stamp & coin Collection, Photography

Permanent Address: No 8, Vijay Nagar, Vivekananda Nagar, Kolathur, Chennai-600099

Declaration

I hereby declare that the particulars furnished above are true to the best of my knowledge.

Date : Yours Sincerely

Place :

(ASHWATH.K)

Personal Information:



Contact this candidate