Bruce Penner
****A ** St NW Edmonton, AB T*C*Z* 780-***-**** **************@*****.***
A natural leader and self-motivated individual who meets deadlines, is easy to get along with and works exceptionally well independently or in a team environment. Earns the respect of co-workers and always available to provide a helping hand. With 15 years’ experience in Industrial maintenance, safety, planning, and construction. Thrives on challenges and believes in doing it right the first time. Highly motivated in planning, construction, maintenance environment where each day has a new challenge and impact of contributions are rewarding.
Te
Canadian Natural Resources Limited
Kirby North Plant/Kirby South Plant/Jackfish Plants 1 2 3
Electrical shut down and small Project work
●Remove EHT as well as preform PMs and inspect Trace
●Remove power and communication cables on motors to be taken out for Rewound or new motors to be Installed.
●Rack In & Rack Out 600v / Rack In & Rack Out 4160 V SWITCHGEAR
●Preform PdMA on switchgear & motor systems
●Reinstall EHT and check all Parameters on controllers to be accurate
Stuart Olson
Meg energy LTD
Electrical shut down scope
●Put in place generator sets to feed essential systems in the Control Room and in the plant
●Ground all generators to be used for the Temporary Power
●Rack out out 4160 volt breakers including 600 MCCs as per the work scope
●Pull down All igniters on the flares down in the Plant and inspect clean or replace as required
●Removal of EHT sr and mi trace for mech scope of work. Re install All trace back on pipes as per the iso drawings. Megger All SR & MI Reinstalled back onto pipes and Valves.
●Energize 4160 volt breakers along with 600 MCCs. Bring online Corresponding VFD Drives.
●Assist operations with bringing plant back online and Commission new Electrical Equipment
AECOM Maintenance 2015 - 2022
Imperial Oil Kearl Lake
Electrical Maintenance in Live Plants & Mine
Terminated motors, devices, junction boxes and control panels
Fabricated and installed device supports
Install and terminate devices, Replace if necessary
Installed heat trace SR & MI & RTD’s
Fabricated and installed cable tray & Instrument Tray.
Troubleshoot VFD’s And Motors and associated Electrical Equipment
Maintain effective communication with Operations and Other Trades Involved
Work on all MCC, Transformers and Power Distribution Associated with 120/208, 600 and 4160.
3.5 Years trouble shooting & installing EHT & RTDs
QA/QC Heat Trace Installs in live Plants
Commissioning Heat Trace Controllers
Programming EHT Controllers and replacing SSRs & RTDs
Replacing defective Controllers and installing with New.
FT Services
2009 - 2015
Canadian Natural Resources Limited Horizon
Electrical/Instrument Apprentice Tech
●Troubleshoot electrical circuits and fire alarm panels
●Troubleshoot electrical breakdowns
●Changed motors VFD’s and motor controls
●Repaired Defective Equipment
●Preform Daily, Weekly and Monthly PM checks
●Provide hands on support from DCS Delta V Systems through to E & I repair’s
●Work on all MCC, Transformers and Power Distribution associated with 120/208 600 4160V
●Preform diagnostics, calibrations and repairs on Temp, Vibration, Pressure, Flow Instruments
●3 years on EHT Crew troubleshooting and Preforming PMs
●Removal & Reinstall of MI and SR Trace & RTDs
●Commission of EHT Controllers
●Replacement of Defective Controllers with new
●Programming of Newly replaced Controllers
Vector Electric and Controls 2005 - 2009
EPCOR City of Edmonton Wastewater and Water Treatment Plants
Electrical Industrial and Commercial Apprentice
●Bending and threading rigid conduit in water treatment plants and substations
●Building instrument and ladder tray for instrument and electrical devices
●Terminations in MCC PLC Cabinets and transformer connections
●Fire alarm construction on a 12 Story commercial base building project
●Pre pair daily tasks for crew members and provide training to other apprentices
●Construction of lighting and lighting retrofits on large projects
●installation of new installs of motors and MCC and VFD Drives
●Heat Tracing of process water pipes
●New Installations of Heat Trace on freeze potential pipes
●Read Isometrics to correctly install Heat Trace
●Program and commission newly installed Controllers.
CRS Crane systems
2003 – 2005
Electrical Manufacturing Apprentice
●Worked In Panel Shop Building Control Panels for Crane Controls
●Installing and wiring motors on overhead cranes
●External wiring on hoist and bridge sections
●installing limit switches to control crane movement
●In the service department, commissioned new cranes
●Responded to troubleshooting calls
●Hi-Pot testing circuits required for QA/QC
Bruce Penner
NORTHERN ALBERTA INSTITUTE OF TECHNOLOGY Edmonton, AB
Construction/ Industrial Electrical
1st & 2nd Year
3rd & 4th year
Alberta Journeyman Electrical Certificate
Saskatchewan Electrical journeyman License
TOFIELD High School, Tofield, AB
Graduated Grade 12
1996
Additional Training: Energy Training Canada
Leadership Management Training
CSTS 2020 (Fundamentals)
Mobile Elevating Work Platforms
OHS Alberta Legislation Awareness
Wood Buffalo Wildlife Awareness
Common Safety Orientation
Nuclear Gauge Awareness
Confined Space Entry and Monitor
First Aid & CPR//AED Level C
Fall Protection
H2S Alive
Hazard Identification, Assessment and Control
WHMIS 2015 Worker Education (CSTS-2020)
Arc Flash Hazard Awareness
Driving & Journey Management (CSTS 2020)
CSTS-2020 (Fundamentals)
Norms Awareness
Fire Watch
Radiation Awareness
Powder-Actuated Tools Safety Training
References Available Upon Request
WORK EXPERIENCE