Post Job Free
Sign in

Mechanical Engineer Special Projects

Location:
Paradip, Odisha, India
Posted:
September 01, 2024

Contact this candidate

Resume:

CURRICULUM VITAE

F/MR/**/CV/INSP Rev * : **nd July, 2020 Page 1 of 5

Email: ***********.*******@*****.***

Mobile No: 933-***-****

Personal Profile:

Full Name : : SAMEER PATRA

Date of Birth (DD-MM-YYYY) : 10-04-1987

Nationality : INDIAN

Languages Known : ENGLISH, HINDI, ODIA

Educational Qualification (s) : Course Name Year of Passing (YYYY) B.TECH in MECHANICAL

ENGINEERING

2011

Professional Qualification (s) /

Achievement(s)

: Course Name Validity (DD-MM-YYYY)

NDT Level II in UT,RT,MPT,LPT & VT .

February 2028

Skill Enhancement Training

attended

: MS Office, Windows 9X/2000/XP, 10,

MSP, MS Excel

YES

Total Experience (Years) : 10years 5months

Experience with TUV (Years) : 5 months

Designation : Inspection Engineer.

Summary of expertise and

special projects handled

2 x 6 MTPA Pellet plant JINDAL STEEL ODISHA

LIMITED

Inspection of Fabrication & Erection of all the process area for Blast Furnaces and structure Fabrication & Erection . Project Responsibilities:-

Inspection of various Process area like CAST

HOUSE,STOCK HOUSE,HOT STOVE,AXIAL

CYCLONE,PUMPHOUSE,PCI,HSG,TOP STRUCTURE &

FURNACES CELL as per ASME SEC-V,ASME SEC – V,

VIII, IX .

Approval of PQR & WPS,WPQ welder qualification as per ASME section –IX,AWS D1.1 .

Welder performance Monitoring .

CURRICULUM VITAE

F/MR/42/CV/INSP Rev 1 : 22nd July, 2020 Page 2 of 5

Witnessing material check testing at various NABL accredited laboratories .

Approval of WPS & PQR .

Employment details: APS Group

Date ( From/ to ) Sep-2022–Aug-2023

Location Vadodara, Gujurat

Description Quality Engineer .

Summary of expertise and

special projects handled

: API 5L PSL-1 (Gr. X42 to Gr. X70) and PSL-2 (Gr. X42 to Gr. X70) for sizes > 8” to 20”. Scope involves Raw Material Inspection, Hydro Test Witness, Mechanical Testin,g, and Visual

& Dimension for various clients.

Inspection of Various types of pipes (Carbon Steel, SS, Alloy Steel) and Heat Exchanger Tubes carried out at manufacturing plants, Stockiest go down, TradersYards Etc,

Manufacturing Type: Seamless (Hot Finish and cold drawn), ERW Type of Pipes Inspected:

ASTM

A 106

Gr.B,

API 5L

Gr.B,

X52.

ASTM A 333 Gr.6Activities in

Brief (Seamless)Raw Material

Identification as per TC

Witnessing NDT like UT, and MPI as per the requirement Heat Treatment If applicable monitoring or review of records as per therequirements

Hydro test witnessing as per requirements

Witnessing Mechanical testing like Tensile, yield, %Elongation, bend test,Hardness, Impact

Visual, and Dimensional Inspection.

Review of Heat treatments, and stress relieves records. Monitoring the straightening operation, verifying the Diameter, ovality, straightness, thickness color cording as per spec.

Verification Facing, Bevel angle, root face (No sharp edge) SA sampling of the pipes for product analysis and mechanical properties as perCode and Purchase order requirement . Final Stage Inspection, Visual Inspection of pipes (surface damages, thread damages, straightness etc.), marking as per PO requirements, Dimensions like OD,Length, Thickness etc. Ensuring the rest preventive coating, ensuring the thread protector quality (visually), identification stamping as applicable.

Witnessing of calibration of u.t.m &

impact machinesWelding inspection,

approval of WPS and PQR

Inspection of drill pipes, visual, dimension, drift test, hardness test. CURRICULUM VITAE

F/MR/42/CV/INSP Rev 1 : 22nd July, 2020 Page 3 of 5 The above mentioned activities are in general nature for all Pipes; the specific scope is depending on the agreed QAP and Purchase Order. I have carried out allthe above activities .

Date: (from/to)

APR 2022-sep-2022

Company/Location: B.E.W Pvt Ltd, Odisha

Designation: Piping Engineer (QC department)

Date: (from/to) Aug 2021-Nov 2021

Company/Location: Vichitra Construction, Odissa

Designation: Inspection Engineer

Date: (from/to) Dec 2019-Oct 2020

Company/Location: B.P.C,Orissa

Designation: Senior Engineer in Quality

Date: (from/to) Oct 2017-Nov 2019

Company/Location: Artson Engineering limited, Odissa Designation: Senior Engineer in Quality

Date: (from/to) Jan2013-Dec 2016

Company/Location: Metal Crafts Constructor Pvt Ltd, Odissa. Designation: Piping engineer.

Date: (from/to) AUG 2012–DEC 2012

Company/Location: S.M. Elemech, Odissa

Designation: Site Engineer.

Date: (from/to) Aug 2011 - Jul 2012

Company/Location: Lanco Infratech Pvt Ltd

Designation: Site Engineer.

Job Responsibilities:

Raw material identification.

Reviewed of WPS, Witnessed of PQR & Welder Qualification as perASME Sec IX, AWS D1.1.

Fit -up inspection & Inspection before Welding, during welding& after welding for visual.

Inspection before PWHT for thermocouple verification & Reviewedof PWHT Chart (Not applicable for Structural CURRICULUM VITAE

F/MR/42/CV/INSP Rev 1 : 22nd July, 2020 Page 4 of 5 items).

Storage tank API-650 inspection of weld joints.

Shell plate, bottom plate, annular plate dimension inspection ofstorage tanks.

Inspection of Hardness of rubber liner of storage tank.

Inspection of painting of tank shell, roof wind girder, nozzle etc.

Viewing of RT films of welds.

Witnessed UT, PT, MPT of welds.

Witnessed of Loading & unloading of PWHT

Witnessed Hardness test on Weld, HAZ& base metal after PWHT.

Final inspection before Hydro test (Not applicable for Structural items)

Witnessed of Hydro Test(Not applicable for structural items)

Reviewed of Documents.

Qualification and performance monitoring of welding personal.

Supervision and inspection welding, pre-heat and post weld heattreatment of weld.

Development and implementation of inspection checklist andreport/format.

Co-ordination of all destructive and Non-Destructive testing AND Various other activities at various sites for different Clients.

Reviewing final packages for hydro tests, approving & releasing forhydro test.

Monitoring of various welding like GTAW, MIG, SMAW.

Carry out inspection of die Penetrant test or MPI for shell plateswith bottom plates filet weld.

Also leading a team of surveyors in various projects.

Exposer in structural, Tank, Piping, pressure vessel storage tanksand various offshore structures. I hereby declare that the above information is correct. Date-16.1.2024

Place-JAJPUR

Signature

SAMEER PATRA

--END of DOCUMENT--

CURRICULUM VITAE

F/MR/42/CV/INSP Rev 1 : 22nd July, 2020 Page 5 of 5



Contact this candidate