Post Job Free

Resume

Sign in

Low Voltage Outlet

Location:
Aqaba, Jordan
Posted:
April 20, 2024

Contact this candidate

Resume:

No.

Discription

* *

* ***** **** ****** *******

5.1/Plush mounted socket outlet of 16A/1P

* */***** ******* ****** socket outlet of 16A/1P

5.3 Flush mounted socket outlet type 20A/ 1P

5. 4 Flush mounted socket outlet type 25A/ 1P

5/Telephone Points/Outlets- inside PVC pipe size of 16mm

diameter from riser point to junction box, and PVC pipe size of

16mm diameter from junction box to every individual telephone

5.1/Telephone points fed through 4core structure(UTP 1 x 4 x 0.5m-

cable measured separetly below) inside PVC conduit of 16mm

diameter.

5.2\Telephone 4core structure(UTP 1 x 4 x 0.5m) bare copperconductor

5.3 RJ 11 outlet type LEGRAND Suno 7740 38 + 7740 41 or equivalent

having category 5E with 4 contacts complete with clip on support

frame.

6 TV Outlet points

6.1/TV outlet point fed through PVC insulated RG6/U coaxial cable

(cable measured separetly below) in conduit of 19mm diameter

including junction boxes with covers for flush mounting.

6.2 RG6/U coaxial cable

6.3\TV coaxial socket outlet type having category 6 with 4 contacts

complete with clip on support frame.

FEEDER CABLES ( tentative measurment)

8.1 \Cables from KWh meter to MDB-GF and type of cable NYY

0.6/1kV, size of 3x50/25+1x25mmsq.

8.2 Cables from MDB-GF to SDB-GF type of cable NYY 0.6/1kV, size of

5 x l6mmsq.

8.3 Cables from SDB-GF to SDB-2BF type of cable NYY 0.6/1kV, size of

[5 x 10mmsq.

8.4 Cables from MDB-GF to SDB-2F,SDB-2F & SDB-4F type of cable

NYY 0.6/1kV, size of 5 x 4mmsq.

8.5 Single PVC insulated green-yellow earth cables from Earth

\electrode to earthing terminal of the MDB, size of 1 x 16mmsq.

9) POWER AND TELEPHONE LINES INTAKE /ENTRY

9.1 Manhole in brick or masonry, internally plastered with 10cm mass

concrete base and 8cm thick including reinforced concrete cover

with lifting lug and size of 600x600x700 mm

10 CONDUITS AND PIPES

10.1 PVC pipe of 110mm diameter

10.2} PVC pipe of 32mm diameter

11;/LOW VOLTAGE SYSTEM EARTHING

[Low voltage system earthing consisting of 1x 16mm? bare copper

lconductor

(2m) inside concrete pipe as hown on the drawing

bonded to earth terminal of EEU KWh meter board,earthing rod

(2400 x16mm) (complete with driving stud, coupler, spike, and rod-

to cable clamp, etc).

12/LIGHT FITTINGS as described here below or equivalent.

12.1] Fitting type No-1-RZB 31 1672.004 19501m with LED 30W lamp.

12.2 Fitting type No-2-RZB 311562.000 19501m with LED 25W lamp.

12.3] Fitting type No-3-RZB 451 163.009 47501m with LED 33W lamp.

12.4 Fitting type No-4-RZB 21 1207.002 560lm with LED 9W lamp

12.5] Fitting type No-5-RZB 451168.002 910Im with LED 10W lamp.

12.6] Fitting type No-6-RZB 311880.00 15501m with LED 19W lamp.

12.7 Fitting type No-7-RZB 311731.002.3 13501m with LED 27W lamp.

12.8] Fitting type No-8-RZB 311730.002.4 980Im with ED 18 lamp

12.9} Fitting type No-10-RZB 312380 002.76 21001m with LED i lamp.

12.10} Fitting type No-11-RZB 901451 .002.1.76 530bm with LED 5W lamp

12.11) Fitting type No-12-RZB.451161.009 2700lm with LED 26W lamp.

mn

=

BOO for 2B+Gs+q

Unit Contract Ee ae

saute tea _= ~e cate Contract Amount

NO 104

NO 15

No. 5

No. 4

NO 8 4

M 150 i

NO 8

NO 10 ‘3

M 150 a

NO 10 ~

M iS -

M 10 -

M ip

M 45 - )

}

M 60 ~ on

)

No. 3

M 15)

M 60

NO rl

No. Z “

No. 4

No. 8

No. 12

No. 13

No. 62

No. 14

No. 18

No. 1

No 98

No 7



Contact this candidate