Muhammad Ihsan
Associate Engineer (BSS+Power, M/W)
Cell# 034********, 030*-*******
FATHER NAME: ABDUL KARIM
CNIC : 32202-9173824-3
AGE: 35 YEARS
BLOOD GROUP: B+
Address: ward no,6 near gulzar e madina masque fateh pur, distric layyahss (Pakistan)
Email: ad0me9@r.postjobfree.com
Objective;
Seeking a challenging position in the field of Telecommunication where I could utilize my experience, technical knowledge and skill that prove myself as an asset for the organization.
Professional Experience
15 Years’ Experience of BSS, POWER and Microwave Transmission system of different vendors like
HUAWEI, SIEMENS, NSN,
ALCATEL, NEC, MOTOROLLA, HARRIS STRATEX and used by almost all the GSM and WiMAX operators of Pakistan in their network expansion throughout the Pakistan.
ELECTROZONE (PVT) LIMITED APRIL 2017 TO TILL DATE
Insalation and cutover of 2volt battry bank
Installation and cutover of lithium batries bank
Installation of rectifier cabnet
Swape the rectifier of zte, shoto,and DPC
Alarm configuration of rectifier and bts
Soler panel installation and configretion
Troubleshooting all kind of rectifier
Genset installation and configuration
Alarms troubleshooting
Installation of roll out sites Huawei and zte
Addition and dismantling of rru and aenteenasss
CLUSTER OWNER CM PAK (ZONG) JAN 2015 TO 2017
Troubleshooting Rectification of operational ZTE BTS.
Troubleshooting Rectification of operational Microwave Huawei link.
Troubleshooting Rectification of Rectifiers’ ZTE.
Troubleshooting of system alarms.
Checking health of batteries.
Troubleshooting of AC powers in ATS panel.
Operational Responsibility of the all sites of the allotted zone.
(BSB Power) May 2012 to Jan 2015
Installation of BSB battery cabinet.
Cut over of power in rectifier in running situation.
Configuration of power one, Elteck, Delta rectifiers.
Maintenance of these rectifiers.
Verification of rectifiers alarms.
Battery health test using inistrometer.
Telecom sub Engineer (MYSON ENGINEERING SYSTEMS) July-2006 to April 2013
Installation, Integration and commissioning, PAT & alarm testing of Siemens & Nokia BTS (BS-240XL, BS-240XLII, Nokia Ultra, Flexi BTS
Expansion of soft 900/1800, complex 900/1800 and Band addition.
Installation, commissioning and troubleshooting of Siemens radio management (SRAL XD, SRA4 PDH &SDH) systems.
Up gradation, Link Dismantling and traffic shifting of SRAL XD & SRA4 radio systems.
Installation, commissioning and troubleshooting of NEC (PASOLINK NEO PDH and SDH)
Up gradation & down grade, Link Dismantling and traffic shifting of NEC. Responsible for implementation, Installing, Commissioning and Managing DBS3900 and RTN620 for various Augere, WI-MAX sites in Karachi.
Implementation, Installing, Configuring, and Commissioning RTN Optic 610/620 Huawei-T2000 web LCT and Harris Stratex Networks (PDH/SDH/Ether Multi Access Platform) (Microwave/RF Bridge) for various Agree (WIMAX), UFONE, Warid b/w Hub site, BTS in c1 and c2
Implementation, Installing, Configuring, Commissioning of HUAWEI BTS (3012, 3012AE, 3900), NOKIA ULTRA BTS, Motorolla BTS, Nokia Flexi BTS and Siemens BTS.
Implementation, Installing, Configuring, Commissioning NEC Paso Link NEO PNMT-J (PDH/SDH/Ether Multi Access Platform) (Microwave/RF Bridge) for UFONE and Mobilink.
Having a full command over testing the VSWR and TRx Power by using Site Master of ANRITSU(S331D) and Bird Site Analyzer
Having a full knowledge of TSS, Panoramic Survey, LOS and Drive Test and Documentation such as PAT, RFI, HSQR, WO, WAP and PAR etc.
Deployment Projects;
I have worked on these projects with MYSON ENGINEERING SYSTEMS
HUAWEI WiMAX Project for AUGERE and Motorolla WiMAX Project for Wi-TRIBE.
HUAWEI BTS and MW Deployment Project for UFONE and WARID Telecom.
NSN Project for Telenor Pakistan and HARRIS STRATEX Project for UFONE
HUAWEI BSC Installation for UFONE(D.I.Khan and Karachi)
HUAWEI Transmission (RTN620) project for UFONE,WARID and AUGERE
NEC Project for MOBILINK, TELENOR and UFONE.
Power Equipment Experience;
I have worked on PMCL Power Swap Project in South, North and central Region.
I have full knowledge of Rectifier of DELTA2000, EMERSON and Power Saft.
I have full experience over Testing and Maintenance of Genset, ATS, ACDB and Relays.
Testing Equipment Experience;
I have full command over testing VSWR & TRx Power by using the Site Master of ANRITSU & Bird.
I have full experience over Testing Microwave E1s. By using the BERT Meter of AOURORA TANGO.
Testing the Microwave Ethernet media by using the Ethernet test Meter (EXFO AXS-200)
I have a good knowledge to perform the following tests i.e. Sweep test, BER test, Ethernet test, Frame loss test, Ping test, Band width test, Latency test and Iperf test.
Professional Qualification;
(DAE) Diploma of Associate Engineer (Electronics)
Punjab Board of Technical Education Lahore
Education;
SSC (Science)
BISE Dera Ghazi Khan
Skills and Trainings;
Electrical essential & Networks, Rectifier and power supplies (Emerson), Basic Electronics, Different Telecommunication System, Optical Fiber & Digital Communication, Cellular Communication, Antenna, and Computer & Its Applications. Windows Vista, XP, Me, 2000, 98 & MS DOS,MS Office complete, Hand Held Software for Site Master of ANRITSU,WEB-LCT Software for Huawei RTN600, Site Maintenance and Terminal Software for Huawei BTS, Eclipse Portal Software for Stratex Networks, Internet Browsing, PNMT,HYPER Terminal and NEO for NEC Paso link and LMT for DBS3900
I awarded an honorary certificate from Myson Engineering System (performance of year 2007)