Post Job Free
Sign in

Electrical maintenance and commisioning

Location:
Vellore, TN, 632001, India
Posted:
February 10, 2017

Contact this candidate

Resume:

SARAVANAN.T.U.

INDIA, VELLORE

+919*********

EMAIL: ***********@*****.***

OBTECTIVE

Seeking a challenging opportunity where I will be able to utilize my strong organizational skills, educational background, and ability to work well with people, which will allow me to grow personally and professionally. I am self-motivated and able to work both independently and as collaborative team member.

STRENGTH - CAREER EXPERIENCE

Dedicated Professional with 13+ years Experience in the field of Electrical machines commissioning, preventive, Predictive & corrective maintenance and other associated Electrical Switching activities.

Involving in Preventive maintenance scheduling and day to day preventive maintenance for Circuit breakers, Motors, Starter Modules, Transformers based on SAP Work orders.

Synchronizing, Operation Cum Maintenance, Routine checkups of 11KV Turbine & Diesel Generator sets.

Preventive Maintenance of HT/LT circuit breakers of VCB, MOCB, OCB, ACB, MCCB & MPCB.

Maintenance for VARIABLE FREQUENCY DRIVES up to 15MW.(Synchronous motor)

Working experience on VSCF (Variable speed constant frequency) Hydraulic turbine generator.

Following the LOTO (Lock Out Tag Out) procedures throughout the complex in order to conduct safe isolations/De-Isolations on electrical equipment’s.

Reading of HT/ LT single line diagrams, protection and metering diagrams, switchgear control diagrams, Motor control diagrams Marshalling and interlocks diagrams.

Reading Knowledge of diagrams, Control Panel, Relay logic and logic gate Diagrams Co Ordination with operation in following up normal start up and shutdown procedures in a continuous process industry.

Knowledge in Safety procedures to work on electrical equipment’s.

Knowledge of hazardous area classifications, NEMA and IEC Standards.

Implements and observes the Company’s HSE policies and procedures.

Cathodic protection transformers and S2M Magnetic Bearings.

Maintenance, Troubleshooting and servicing of Motor Operated Valves (ROTORK).

Maintenance of battery charger & UPS installation & Maintenance of Batteries.

WORKING EXPERIENCE

Working at PEINER SMAG MACHINERY INDIA PRIVATE LIMITED, From April 2014 to Till now, as an Electrical Engineer.

PREVIOUS EMPLOYMENT

Worked at QATAR GAS OPERATING COMPANY, QATAR. From June 2011 to Dec 2013, as an Electrical Technician, LNG PLANT.

Worked as an Electrical Supervisor at THIRUMALAI CHEMICALS LTD., Ranipet India, which is one of the reputed Petrochemical Industries in Asia. Worked from MAY 2003 to MAY 2011. Our company is producing largest Pthalic Anhydride (from O-Xylene).

EDUCATIONAL QUALIFICATION

DIPLOMA in ELECTRICAL AND ELECTRONICS ENGINEERING. First Class with Honours-87%

COMPETENCY CERTIFICATE DEATILS

Authorised Electrical person (AEP) Issued by Qatar Gas Operating Company, Qatar.

Supervisory competency certificate Issued by Govt. of Tamil Nadu, INDIA. No.C38333.

SHIFT OPERATIONS

Electrical co-ordinations for plant start up and running plant operations.

Diagnostic and Trouble shooting of all kinds of electrical circuits.

Recording of various running status of electrical machines (Transformer, Batteries, Motors, Energy readings, etc.,)

Load sharing operations, at critical and normal situations in the running plant.

Changeover between normal and emergency power operations.

SYSTEM HANDLED SO FAR

POWER GENARATION:

Utility power generation : 2 x 33 MW 11KV Gas turbines Generator (GE).

: 3 x 43 MW 11KV Steam turbines Generator (MITSUBISHI).

: 4 x 5MW Emergency diesel generator (AVK).

6450KVA, 2306 KVA & 1806 KVA, 11KV Steam Turbine Generators (LEROY SOMER, AEG)

1150 KVA & 1100 KVA, 11 KV Diesel Generator (SKL)

1000 KVA (SULZER) – 2 Nos. of 380V LT Diesel Generator with 2 MVA 380V /11KV Step up Transformer.

750 KVA, 415V (Kirloskar) Turbo Generator.

POWER TRANSFORMER:

66KV/33KV, 120 MVA Outdoor Transformer

33KV/6.6KV, 20 MVA Outdoor Transformer

6.6KV/415V, 2 MVA Outdoor

11KV/3.3KV, 1250 KVA Outdoor Transformer

11KV/520V & 415V, 2MVA Outdoor Transformer (Bharat Bijilee)

11KV/415V, 1600KVA Outdoor transformer.

SWITCH GEARS PANELS:

66kv, 33KV SIEMENS & AREVA – Metal Clad SF6 Gas Insulated Switchgear.

33kv AREVA – Metal Clad SF6 Gas Insulated Switchgear.

6.6kv ABB Korea- Metal enclosed switch gear.

415v ABB Malaysia Switchgear with INSUM MCU2 motor Management system.

CIRCUIT BREAKERS:

HV: 66kv, 33kv SIEMENS & AREVA SF6 Breakers.

HV: 11KV, 630A, 350MVA VCB / MOCB (SIEMENS)

: 11KV, 400A, 250MVA OCB (Crompton Greaves).

MV: 6.6KV 630A VCB (ABB).

LV: PCC Rating up to 3200A (Manual & Motorized) ACB’s (L&T, ABB, GEC Alstom).

PROTECTION SYSTEM

Protective Relays ABB REF542plus integrated multifunctional device for transformer protection and SIEMENS SOLKAR relay and for 87T protection. Protective Relays SIEMENS SIPROTEC for 87L protection.

Protective Relays ABB REM543 microprocessor-based relay for MV motor protection.

Protective Relays GE SR489 generator management relay for Generator protection.

UPS Systems and Battery Charger System of Make GUTOR (10KVA to 220KVA).

GE Multiline SR 750; SR 745; SR 489. Transformer Protection Relay; Siemens SIPROTEC.

MOTORS:

MV: 7.2kv 15MW*4 Synchronous motor/Generator.

6.6KV up to 3.2MW ABB Motors.

3.3KV, 980KW, 800KW & 650 KW, NGEF MAKE Induction Motors.

LV: 500V, 415V & 380 V AC Induction Motor from 0.37KW UPTO 180 KW of

Makes - Siemens, Kirloskar, Crompton Greaves, ABB, NGEF, BBC.

VFD:

Siemens 15MW*4Drives, 3Units (33kv/7.2kv) water cooled system.

Amtech up to 15 KW, DANFOSS 30 KW (D.O.L. Starter Panel) & 45 KW (Soft Start panel)

UPS/BATTERY CHARGERS:

10 KVA to 220KVA Tata Libert & GUTOR.

10 KVA, 15 KVA NELCO

STARTERS:

D.O.L Starter.

Star – Delta Starter.

Two speed, For / Rev Starter.

Soft Start Starter.

PERSONAL DATA

Name : T.U.SARAVANAN

Father’s name : Mr T.UMAPATHY

Date of Birth & Age : 10-09-1984 / 29 Yrs.

Nationality : Indian

Marital Status : Single

Passport Details : H 2108979

Issued at Chennai

Valid up to 09.12.2018

Permanent address : No, 12/1 Bharathi dasan street,

Near devi nagar,

Arcot- 632503,

Vellore district, Tamil nadu.

DECLARATION

I hereby declare that all the details furnished in this resume are true

To the best of my knowledge and belief.

Regards,

T.U.SARAVANAN



Contact this candidate