CURRICULUM VITAE
MADHIVANAN .A
Position : Electrical Testing and Commissioning Engineering.
Experience : 10+Yrs .
E-mail ID : **********@*****.***
Mobile : +971*********,+919*********
Nationality : Indian
Summary
Looking for a challenging position in Electrical Installation, Testing& Commissioning field of Oil and Gas, Power Projects, Industrial utilities, which offers me a dynamic environment to grow with the organization and to play a key role to achieve Organization Goals
I have almost 5+ years experience in Oil & Gas area(Onshore&Offshore) – 132KV/11.0KV/6.6KV/3.3KV/410V Electrical Distribution System, Electrical experience of Low and Medium Voltage MCC's, Switchgear, Switchboards,UPS,Battery bank,Transormer,Motor,generator,Ecms and electrical distribution products,
3+ years Electrical Engineering experience of gulf market (UAE&IRAQ)
Regulatory codes: Experienced with national and industry code: ANSI/IEC, IEEE Effective communication, interpersonal, problem-solving, planning and coordination skills
Always take pride in doing a job, willing to learn new skills, team player, confident and responsible,
Professional Qualiification:
Bachelor of Electrical and Electronic Engineering
Year of completion : April 2011
Diploma Electrical and Electronic Engineering
Year of completion April 2008
Certificates of HSE :
H2S(OPITO)
TBOSIET(OPITO)
ADMA OPCO PTW
PROFESSIONAL EXPERIENCE IN OVERSEAS;
BORGE GENERAL CONTRACTING AND ELECTROMECHANICAL, Abu Dhabi, UAE.
(Presently Working as an Electrical Installation, Testing and Commissioning Engineer, IRAQ,UAE from JAN 2014 to till now)
ENGINEERING RESPONSIBILITIES
Preparation of as built site layouts, Single Line diagram and Schematic diagrams.
Preparation of commissioning of MV network system
Preparation of project documentation not limited to material submittal, reply to consultant question, site planning, protection philosophy, daily/monthly progress report.
Coordinate with equipment suppliers and witness equipment tests at factory.
Preparation of all Electrical studies: - Short circuit Calculation, Coordination studies, Protection Studies.
All site activities comply with company HSE policies.
(a). Project : EPC WORKS FOR ZK FIELD WHT’S ELECTRIFICATION ZWSC/ZCSC TOPSIDE ELECTRICAL WORKS PACKAGE - “A”(OFFSHORE), Abu Dhabi, UAE..
Client : M/S. ABUDHABI MARINE OPERATING COMPANY
Main Contractor: M/S.Npcc
Sub Contractor :M/S.ABB LLC
Preparation of Material submittals for Consultant Approvals.
Preparation of Method Statement for Testing and Commissioning Reports.
Testing & commissioning of 6.6Kv Ring Main unit in Zone IIB T3 Hazardous area,
Numerical relay line differential RED615 Feeder protection REF620,Bay control REU615 Feeder Protrection testing as per Ring Main unit system,
ECMS signal checks.
Under take periodic checking and Maintenance of Electrical Equipments, Panels & Switchgears to attend breakdowns in plant.
Handle the tasks of generating plans for upgrading design and in documenting work policies.
(b). Project : ABK Offshore-ABUDHABI.
Client : M/S. Total
Main Contractor: M/S. E&I LLC.
Under take periodic checking and Maintenance of Electrical Equipments, 11 Kv Panels & Switchgears to attend breakdowns in plant.
Regular updating of stocks of spare materials for Electrical Maintenance.
Handle the tasks of generating plans for upgrading design and in documenting work policies.
Knowledge on the type of permit and lock out tag, prior for isolation of equipment.
Attend some calibration works related for protection system such as generator, motor, transformer, VCB/ ACB relay.
(c). Project : Basra gas KAZ-IRAQ.
Client : M/S. Shell
Main Contractor: M/S.Technip.
Sub Contractor :M/S.E&I LLC
MV/LV Switch Gears Panel Equipment testing and Commissioning Activities.
20MVA Transformer testing and commissioning Activities.
Contol Panel Installation and Commissioning activities. (Schineder).
Testing of MV Power Cables and Preparation of Method statements, Test sheets & Commissioning procedures and As-built Drawing.
(d). Project : Basra gas NORTH RUMAILA-IRAQ.
Client : M/S. Shell
Main Contractor: M/S.Chiyoda.
Sub Contractor :M/S.E&I LLC
MV/LV Switch Gears Panel Equipment testing and Commissioning Activities.
20MVA Transformer testing and commissioning Activities.
Motor Commissioning activities. (Schineder).
Testing of MV Power Cables and Preparation of Method statements, Test sheets & Commissioning procedures and As-built Drawing.
(e) Project : E25 132/11 kv Sub sation ABUDAHABI-UAE.
Client : M/S. ADDC
Main Contractor: M/S ETA,UAE..
Testing and Commissioning of 11kV(Gas insulation subsation)&0.415KV Switchgears panel.
Testing of SIEMENS 7SJ41, 7SJ61 protection Relay by primary and secondary injection for SWGR
Testing of MV Power Cables and Preparation of Method statements, Test sheets & Commissioning procedures and As-built Drawing.
INEL POWER SYSTEM PV LTD, Bangalore, INDIA.
(Working as an Electrical Testing and Commissioning Engineer,(2011-2014))
(A). Project : M/S. Manglore Refinery and Petrochemicals LTD, India.
Main Contractor: M/S.INEL POWER
Testing and commissioning of 11KV (VCB) switchgears (Siemens) & 3.3KV MCC soft starter panel 0.415KV WS-MCC and MV MCC (ACB) switchgears panel (SIEMENS).
Testing of SIEMENS 7SJ41, 7SJ61 secondary injection for SWGR (11/3.3kv) panel.
Scheme and Interlock checking of 11kv switchgears & 3.3kv MCC soft starters and 0.415kv VFD feeders and MDB panels all are checked.
Planning and effecting preventive & predictive maintenance, overhauling, repair schedule of various equipment like VFD, Breakers, Relays &Transformers and instruments to increase machine uptime and long term equipment reliability.
Prepare daily Report, Remarks and equipment history.
Dealing with integrated materials management system.
.
(B). Project : 2*800 MW Power plant.
Client : M/S. APGENCO INDIA
Main Contractor: M/S. Power solution .
Testing and commissioning of 11KV (VCB) switchgears (Schinder) & 3.3KV MCC soft starter panel and 0.415KV WS-MCC and MV MCC (ACB) switchgears panel (SIEMENS).
Testing of Schinder relay P141,P922,P241 and ABB relay REF 630,REU615,REM545,
Testing and commissioning of transformer and Transformer differential stability and sensitivity.
Software Used :
ABB PCM
SIEMENS DIGSI
Schneider Electric S1 Studio
Testing of Numerical Relays :
ABB – ERF 615,REF 630,REU 610,REU 615,SPAU 140,SPAJ 140C,SPAM 140C,REG 543,REM 543,REM 610,REM 615,RED 615,REF 620.
SCHNEIDER-MICOM P111,P141,P143,P121,P241,P922,P343,P341.
SEMIENS-7SJ641
BECTH WIDTH-M3872
Testing of Electromeachnical Relays :
EE-YTGM,O/C,E/F,CTN,ZTO.
ALSTOM-O/C,E/F,UV,OV,Power Relay.
Personal Detailes :
Launages :Tamil,English,Hindi
Nationality : Indian - Tamillan, Born 21/05/1989
Civil Status :Single
Declartion :
I here by declare that all the above information’s are true to the best of my knowledge and belief.
Date: 01/01/2017 Regards,
Place: ABUDHABI Madhivanan.A