POWER SYSTEM ENGINEER
Personal details
Name : S. VASANTH KUMAR
Date of Birth: 20.10.1992
Nationality : Indian
Sex : Male
Marital Status: Single
Contact No : +91-948*******
Email ID : *********.**@*****.***
Languages Known:
English,Tamil,Hindi.
Passport Details:
Passport No.:L8170867
Address:
211/3 Aasath Nagar,
Near ALPS Residency,
Krishnagiri - 635001, Tamilnadu,
India.
Objective
With an experience in the field of Testing and
Commissioning of power system products, I
look forward for an opportunity to display my
skills in the field of Testing & commissioning of
Relays, Maintenance and Execution of projects
related to power systems.
Professional Details
Professional Qualification:
B. E. (Electrical & Electronics) Year of Passing
2014
CGPA : 7.96
Experience : 2 Years
Skil Set
Having an experience and knowledge in
Testing ofGE,SIEMENS,ALSTOM Numerical
Relays
Having an experience in Testing &
commissioning of Control&Relay panels
Having an experience and knowledge in
Scada Co-0rdination.
Having an experience and knowledge of
Relay setting Co-ordination.
Having an experience and knowledge of
Control and Relay panel shceme
designing upto 400KV.
Page 2 of 5
PROFESSIONAL EXPERIENCE:
2 YEARS EXPERIENCE
Organisation
Duration Designation
POG Engineering Cosultants Pvt
Ltd,Bangalore
Jan 2015 – Till Date
(1Year-9 Months)
Testing & Commissioning
Engineer
Shri Shri Spot Electrical Industries Pvt
Ltd
Oct 2014 – Dec 2014
(4 Months)
Service Engineer
Nature of Work
Testing of control & relay panel for Transformer and Line feeder.
Inspection of control and relay panel, preparation of Test Report.
Testing of Protective Relays for various needs.
Knowledge of BusBar Protection,Line Protection, Transformer protection, Line Differential Protection & REF Protection, Disturbance recorder, Interlocks and Isolator Logics.
Operation and Maintenance of Power Plant and sub-station.
Co-ordination with client in As Built Scheme drawing submission, test report submission and all site activities to satisfy the customer.
Relay setting Co-ordination done for Metro Project and Distribution system. POG Assignments
400/220KV AJMER SUBSTATION, AJMER (SIEMENS & ALSTOM RELAY LINE, TRANSFORMER, BUSBAR PROTECTION TESTING AND COMMISSIONING WITH GOOSING & SCADA CONFIGURATION)
220/110/33KV SAMANGARA GRID SUBSTATION,PURI ( SIEMENS AND ALSTOM NUMERICAL RELAY LINE,POWER TRANSFORMER, BUSBAR TESTING & COMMISSIONING WITH CONTROL PANEL) .
132/33KV MUNDALI SUBSTATION, MEERUT (SIEMENS NUMERICAL RELAY LINE,POWER TRANSFORMER, BUSBAR TESTING & COMMISSIONING WITH GOOSING AND SCADA CONFIGURATION)
220/66KV CHATTRAL SUBSTATION, GANDHINAGAR (SIEMENS NUMERICAL RELAY TRANSFORMER PROTECTION TESTING & COMMISSIONING WITH CONTROL PANEL) Page 3 of 5
220/66KV SALEDAJA SUBSTATION, AHMEDABAD (SIEMENS NUMERICAL RELAY TRANSFORMER PROTECTION TESTING & COMMISSIONING WITH CONTROL PANEL).
33/6.6KV TIN PLATE SUBSTATION, JAMSHEDPUR (SIEMENS NUMERICAL RELAY TRANSFORMER, REF, OC/EF PROTECTION TESTING WITH CONTROL PANEL)
230/110KV KUMBAKONAM SUBSTATION, KUMBAKONAM, TN (GE AND ALSTOM NUMERICAL RELAY LINE, TRANSFORMER, BUSBAR PROTECTION, BCU TESTING AND COMMISSIONING WITH GOOSING AND SCADA CONFIGURATION).
220/33KV HAYATHNAGAR SUBSTATION, HYDERABAD, AP (GE AND ALSTOM NUMERICAL RELAY LINE, TRANSFORMER, BUSBAR PROTECTION, BCU TESTING AND COMMISSIONING WITH GOOSING AND SCADA CONFIGURATION).
220/33KV ELLUTLA SUBSTATION, ANANTHAPUR, AP (GE AND ALSTOM NUMERICAL RELAY LINE, TRANSFORMER, BUSBAR PROTECTION, BCU TESTING AND COMMISSIONING WITH GOOSING AND SCADA CONFIGURATION).
220/132/33KV SAMASTIPUR SUBSTATION, PATNA, BIHAR (GE AND ALSTOM NUMERICAL RELAY LINE, TRANSFORMER, BUSBAR PROTECTION, BCU TESTING AND COMMISSIONING WITH CONTROL AND RELAY PANEL ALONG WITH GOOSING AND SCADA CONFIGURATION).
220/132/33KV CHITTOOR SUBSTATION, CHITTOOR, AP (GE AND ALSTOM NUMERICAL RELAY LINE PROTECTION TESTING AND COMMISSIONING WITH CONTROL AND RELAY PANELS).
GE INDIA INDUTRIAL PVT LTD, BENGALURU (GE & ALSTOM LINE, TRANSFORMER, BUSBAR PROTECTION TESTING)
ANDRITZ HYDRO LTD, BHOPAL (GE LINE, LINE DIFFERENTAL, BACKUP PROTECTION TESTING)
DELHI MSW SOLUTION, DELHI (GE MOTOR PROTECTION 200HP TESTING & COMMISSIONING)
ABB FACTORY, NASHIK (GE F650 FEEDER PROTECTION TESTING)
DEPROCON CONTROLS, BENGALURU (ALSTOM NUMERICAL RELAY LINE, LINE DIFFERENTIAL, TRANSFORMER, BUSBAR PROTECTION TESTING WITH SCADA CONFIGURATION)
NR FACTORY, MUMBAI (NR CONTROL AND RELAY PANEL SCHEME CHECKING)
KAKATIYA CEMENT LTD, JAGGAIYAPET (GE TRANSFORMET PROTETION RELAY RETROFIT AND TESTING)
Page 4 of 5
Experience with SIEMENS RELAYS
1. 7SA522,7SA611 – Distance Protection Relay
2. 7UT613,7UT633 – Differential Protection Relay
3. 7SJ62 – Breaker Failure Protection Relay
4. 7SS522 – BUS BAR PROTECTION
5. 7SJ647.7SJ645 – Directional O/C,E/F With Bay control 6. 7SS525– Busbar Bay Unit
7. 6MD63- Bay Control Unit.
8. 7VK61 – Auto Relcosing Relay
9. 7SJ61 – REF Protection
Experience with MICOM RELAYS
1.P444, P442 – Distance Protection Relay
2. P643 - Differential Protection Relay
3. P746 - Busbar Protection Relay
4. P543 – Line Differential Proteciton Relay
4. P341 – Vector Surge Protection Relay
5.P141,P143 - Directional O/C,E/F Relay
Experience with GE RELAYS
1. D60 – Distance Protection Relay
2. T60 – Differential Protection Relay
3. B90 - Bus Bar Protection
4. F650 – Directional O/C,E/F With Bay control
5. L90 - Line Differential Protection
6. MM300/200 - Motor Protection
7. SR745 – Transformer Protection.
8. SR750 - Overcurrent Protection.
Relay Software Handled
DIGSI 4.84,4.86,4.88,4.90
Micom S1 Studio 3.51,5.01,5.3.1, Micom S1 Agile 1.1.0, Micom Schneider Electric 5.0, 5.3
Enervista 650,UR Setup, MM300/200. SR Setup, Enervista Launchpad Page 5 of 5
Test Kit Handled
OMICRON(256,356)
DOBLE (F6150)
PONOVO
Schemes Handled
ABB
AREVA
SIEMENS
L & T
GE
ANDRITZ HYDRO
NR
Goose Signals Configuration Handled
ALSTOM,SCHNEIDER
SIEMENS
GE
SCADA Integration Handled
ALSTOM,SCHNEIDER
SIEMENS
GE
DECLARATION
I hereby declare that all the statements made above are correct to the best of my knowledge and belief
Place : Bangalore Yours Sincerely,
Date : 04-10-2016 (S. VASANTH KUMAR )